ABB REC650 (1MRK008514-CB) – Bay Control and Protection IED for Modern Substation Automation

Brand / Model:ABB REC650 (Ordering code: 1MRK008514-CB)
Device Type:Bay Control and Protection IED (Relion 650 series)
HS Code:853649 (Other relays)
Power Requirements:24–60 VDC or 100–240 VAC/DC variants; typically < 30 W consumption
Dimensions & Weight:1/2 × 19″ rack, approx. 4U height; depth ~200–240 mm; approx. 5–6 kg depending on options
Operating Temperature:−25°C to +55°C (operation); −40°C to +70°C (storage)
Signal Input/Output Types:CT inputs: 1 A / 5 A; VT inputs: 100 / 110 VAC; Digital inputs for 24/48/60/110/220 VDC; High-speed binary outputs for trip/close/interlocking
Communication Interfaces:1–2 × Ethernet 100Base‑TX or FX (variant-dependent); IEC 61850 (MMS/GOOSE); optional IEC 60870‑5‑104 / DNP3 / Modbus; SNTP and/or IRIG‑B time sync; front USB (service)
Installation Method:Panel flush mounting; 19″ rack mounting via subrack or adapter (as required)

Categories: Tags:
contact qrcode

Need help?
Email: sales@fyplc.cn
Tel/WhatsApp: +86 173 5088 0093

Description

ABB REC650 (1MRK008514-CB) – Bay Control and Protection IED for Modern Substation Automation

REC650_1MRK008514-CB_5REC650_1MRK008514-CB_4

The ABB REC650 is a bay control and protection IED from the Relion 650 series, designed for dependable control, interlocking, and measurement in MV/HV substations. The code 1MRK008514-CB refers to a factory-configured variant of the REC650, typically delivered with predefined I/O and communication options, making it straightforward to drop into a standard feeder or breaker-and-a-half bay. From my experience, teams choose REC650 when they want solid IEC 61850 performance (GOOSE, MMS), fast interlocking, and a clear operator HMI without overcomplicating commissioning.

You might notice that the device consolidates bay control, event/oscillography, and process supervision into a compact 1/2 19-inch case. One thing I appreciate is how quickly it integrates with existing SCADA—most projects finish FAT sooner because the data model and templates are well-structured in PCM600.

Our Order Placement Process and Guarantees

  • Warranty: 365 days
  • Delivery: 1 week for in-stock items; no more than one month at the latest
  • Payment: 50% advance payment; full payment before delivery
  • Express options: FedEx, UPS, DHL

Key Features

  • IEC 61850-native with GOOSE – Fast peer-to-peer interlocking and standardized MMS communication, typically cutting control wiring.
  • Flexible I/O for bay control – Digital inputs/outputs sized for common feeder bays; CT/VT measurement for indication, supervision, and check functions.
  • Event and disturbance recording – SOE with time tagging and COMTRADE disturbance files to speed up fault analysis.
  • Front-panel HMI – Clear mimic and programmable keys for local control; operators usually find it intuitive during switching.
  • Time synchronization – SNTP and, in many cases, IRIG‑B for accurate event correlation across the substation.
  • Cybersecurity features – Role-based access and password policies aligned with typical utility practice.
  • Wide-range auxiliary power – Common supply variants (24–60 VDC or 100–240 VAC/DC) simplify spares and retrofits.
  • Engineering with PCM600 – Consistent toolchain for parameterization, disturbance retrieval, and firmware updates.

Technical Specifications

Brand / Model ABB REC650 (Ordering code: 1MRK008514-CB)
Device Type Bay Control and Protection IED (Relion 650 series)
HS Code 853649 (Other relays)
Power Requirements 24–60 VDC or 100–240 VAC/DC variants; typically < 30 W consumption
Dimensions & Weight 1/2 × 19″ rack, approx. 4U height; depth ~200–240 mm; approx. 5–6 kg depending on options
Operating Temperature −25°C to +55°C (operation); −40°C to +70°C (storage)
Signal Input/Output Types CT inputs: 1 A / 5 A; VT inputs: 100 / 110 VAC; Digital inputs for 24/48/60/110/220 VDC; High-speed binary outputs for trip/close/interlocking
Communication Interfaces 1–2 × Ethernet 100Base‑TX or FX (variant-dependent); IEC 61850 (MMS/GOOSE); optional IEC 60870‑5‑104 / DNP3 / Modbus; SNTP and/or IRIG‑B time sync; front USB (service)
Installation Method Panel flush mounting; 19″ rack mounting via subrack or adapter (as required)

Application Fields

The REC650 fits utility distribution feeders, transmission bay control, industrial plant substations, renewables collector bays, AIS/GIS switchgear, and retrofit projects where IEC 61850 is required. A common setup is bay interlocking via GOOSE, synchronized with the station gateway using SNTP, while using local HMI for operator switching during maintenance windows.

Advantages & Value

  • Reliable operations – Type-tested to utility standards; disturbance files and SOE help maintenance teams close incidents faster.
  • Easy integration – Native IEC 61850 and optional legacy protocols simplify migration, typically reducing gateway engineering effort.
  • Lifecycle-friendly – Common hardware platform and PCM600 toolset shorten training and stocking for spares.
  • Wiring reduction – GOOSE interlocking and status publishing cut copper cabling between bays, which saves time during panel build.
  • Support and documentation – Widely deployed with abundant application notes and templates; seems to be one of the easier ABB units to commission.

A protection engineer from a Middle East utility told us their REC650 bay upgrade “took days, not weeks,” largely because GOOSE-based interlocking replaced dozens of hardwired links across the switchroom.

Installation & Maintenance

  • Panel and wiring – Install in a sealed control cabinet (IEC 61439 or equivalent), allow front access for HMI/USB, and provide proper earthing. Keep Ethernet patch leads segregated from CT/VT wiring to limit noise.
  • Ventilation – Normal convection is usually enough; avoid hotspots near heaters or in direct sun. Maintain ambient within the specified range.
  • Network design – Implement managed switches with VLANs/QoS for GOOSE. Redundancy using RSTP and, in many cases, PRP is recommended at bay and station layers.
  • Time sync – Configure SNTP fallback even if IRIG‑B is present; verify time skew during SAT/FAT with SOE stamps.
  • Routine care – Periodic cleaning of front panel, back up configurations from PCM600, review SOE/oscillography after faults, and apply approved firmware updates during planned outages.
  • Testing – Secondary injection for measurement and trip logic after any wiring change; confirm GOOSE subscriptions with network analyzer captures.

Quality & Certifications

  • CE marked; RoHS compliant
  • Type tested to IEC 60255 series; EMC and environmental tests per utility practice (e.g., IEC 61000-6-5 / IEC 60068)
  • UL/cUL availability in many cases for North American projects
  • Manufacturer’s standard quality system aligned with ISO 9001
  • Warranty: 365 days (our supply terms)

Compatible Accessories & Options

  • Substation-grade Ethernet switches (managed, IEC 61850-ready)
  • IRIG‑B GPS time server for precise time stamping
  • Panel cutout frames and 19″ subrack adapters
  • CT shorting terminal blocks and marshalling accessories
  • Replacement power supply modules (voltage range variants)

If you need the exact I/O map and comms card set for 1MRK008514-CB, share your single-line and protocol list—we can verify the variant and align it with your bay template before order confirmation.

Reviews

There are no reviews yet.

Be the first to review “ABB REC650 (1MRK008514-CB) – Bay Control and Protection IED for Modern Substation Automation”

Your email address will not be published. Required fields are marked *