ALSTOM MFAC34N1AA0001A – Plug‑in Control PCB for Legacy ALSTOM/GE Industrial Systems

Brand / ModelALSTOM MFAC34N1AA0001A

HS Code8538.90 (Parts for switching/protection/control apparatus)

Power Requirements24 VDC nominal (typ. 18–32 VDC), consumption typically <10 W

Form Factor / InstallationPlug‑in Eurocard; mounts in 3U subrack with card guide and front panel fasteners

Dimensions & WeightApprox. 100 × 160 mm board size; ~0.25–0.35 kg depending on revision

Operating Temperature0 to +55 °C (cabinet environment, non‑condensing)

Signal I/O TypesI/O via system backplane; digital/analog signaling handled through the rack interface (no field screw terminals on board)

Communication InterfacesBackplane bus (proprietary to ALSTOM rack architecture); front diagnostics if equipped

contact qrcode

Need help?
Email: sales@fyplc.cn
Tel/WhatsApp: +86 173 5088 0093

Description

ALSTOM MFAC34N1AA0001A – Plug‑in Control PCB for Legacy ALSTOM/GE Industrial Systems

MCHN02D1AB0004A_4MCHN02D1AB0004A_3

The ALSTOM MFAC34N1AA0001A is a plug‑in control board used in ALSTOM control racks where reliable, deterministic I/O processing is required. From my experience, this type of MFAC-series card is fitted into a 3U subrack and interfaces through a backplane connector, making it a practical drop‑in when you’re maintaining installed ALSTOM equipment without reworking wiring or software logic. You might notice that it’s often specified as part of turbine/plant automation and traction-related cabinets, where stable 24 VDC operation and clean signal handling matter more than flashy new features.

Order Placement Process and Guarantees

  • Warranty: 365 days
  • Delivery: 1 week if in stock; no more than one month at the latest
  • Payment: 50% advance payment; full payment prior to delivery
  • Express Options: FedEx, UPS, DHL

Key Features

  • Plug‑in Eurocard Design – Slides into a 3U subrack, reducing downtime during changeouts.
  • Backplane Connectivity – All I/O and control signals route via the rack backplane for neat, serviceable wiring.
  • 24 VDC Control Power – Typically operates from a stable 24 VDC rail common in plant cabinets.
  • Service-Friendly Front Access – In many cases, status LEDs/test points help with quick diagnostics.
  • Form/Fit Compatibility – Intended as a like‑for‑like replacement within ALSTOM assemblies, minimizing software and logic changes.
  • Stable Operation in Cabinet Environments – Suited to conditioned control rooms and traction enclosures with proper ventilation.

Technical Specifications

Brand / Model ALSTOM MFAC34N1AA0001A
HS Code 8538.90 (Parts for switching/protection/control apparatus)
Power Requirements 24 VDC nominal (typ. 18–32 VDC), consumption typically <10 W
Form Factor / Installation Plug‑in Eurocard; mounts in 3U subrack with card guide and front panel fasteners
Dimensions & Weight Approx. 100 × 160 mm board size; ~0.25–0.35 kg depending on revision
Operating Temperature 0 to +55 °C (cabinet environment, non‑condensing)
Signal I/O Types I/O via system backplane; digital/analog signaling handled through the rack interface (no field screw terminals on board)
Communication Interfaces Backplane bus (proprietary to ALSTOM rack architecture); front diagnostics if equipped

Application Fields

This board is commonly used in legacy ALSTOM and GE‑acquired industrial control systems where rack‑based modules manage plant processes:

  • Gas/steam turbine control cabinets and balance‑of‑plant I/O frames
  • Power generation auxiliary systems (pumps, fans, fuel handling)
  • Rail and traction substations using ALSTOM rack architectures
  • Industrial utilities in process plants that standardize on ALSTOM racks

Advantages & Value

  • Risk Mitigation – Like‑for‑like replacement helps avoid re‑qualification of loops and logic, which typically saves days of commissioning.
  • Cost Control – Extends the life of installed assets without forcing a full system upgrade.
  • Compatibility – Maintains backplane pinout and timing characteristics expected by adjacent ALSTOM modules.
  • Serviceability – Front extraction screws and guided slots simplify swap‑outs during outages.
  • Documentation Support – We can typically share handling guidelines and installation notes to speed up work orders.

Installation & Maintenance

  • Cabinet Requirements – Install in a clean, ventilated control cabinet; maintain ambient 0–55 °C and non‑condensing humidity.
  • Rack Standard – 3U Eurocard subrack; verify slot addressing and backplane keying before insertion.
  • Wiring – Signals are backplane‑routed; confirm connector seating and retention before power‑up.
  • ESD Handling – Use personal grounding and antistatic packaging; avoid touching component surfaces.
  • Routine Care – Periodic cabinet dust removal (dry air) and connector inspection; firmware/config updates as per site procedures, if applicable.
  • Startup Checks – After installation, verify power rail quality (24 VDC), observe status LEDs, and run loop checks if the process allows.

Quality & Certifications

  • CE – Typically supplied for integration into CE‑marked control systems.
  • Manufacturing Quality – Produced under ISO 9001 quality systems (factory‑level).
  • RoHS/UL – Varies by production year and system; individual plug‑in boards are not always separately UL listed.
  • Warranty – 365‑day coverage as stated above.

One thing I appreciate is how this module keeps upgrades simple—most teams just schedule a short outage, pull the old card, and seat the replacement. A maintenance manager at a combined‑cycle plant told us they swapped a pair of these in under 30 minutes, with trends back to normal after a quick loop validation. If you need compatibility confirmation against a specific rack or firmware revision, share the rack ID and slot plan and we’ll match it carefully before shipping.

Reviews

There are no reviews yet.

Be the first to review “ALSTOM MFAC34N1AA0001A – Plug‑in Control PCB for Legacy ALSTOM/GE Industrial Systems”

Your email address will not be published. Required fields are marked *

zzfyplc_Lily