Bently Nevada 190782-01 Communication Gateway Module – Reliable Modbus/Ethernet bridge for 3500 monitoring systems

Brand / Model Bently Nevada 190782-01 (Communication Gateway Module for 3500 systems)
HS Code 9032.89.0000 (Automatic regulating or controlling instruments; other)
Power Requirements Powered from 3500 rack backplane; no external power supply required
Dimensions & Weight Standard single‑slot 3500 plug‑in module form factor (fits existing 3500 racks)
Operating Temperature Typically 0 to +65 °C for installed 3500 modules (indoor, protected enclosure)
Signal Input/Output Types Data interface to 3500 backplane; external I/O as Modbus registers and status/alarm bits
Communication Interfaces 1× RJ‑45 10/100Base‑T Ethernet; RS‑232 (DB‑9) and RS‑485 (terminal) for Modbus RTU; standard baud rates up to 115.2 kbit/s
Installation Method Plug‑in module for Bently Nevada 3500 rack with rear I/O module and terminal assemblies

contact qrcode

Need help?
Email: sales@fyplc.cn
Tel/WhatsApp: +86 173 5088 0093

Description

Bently Nevada 190782-01 Communication Gateway Module – Reliable Modbus/Ethernet bridge for 3500 monitoring systems

bently_190782-01_communication_gateway_module_3bently_190782-01_communication_gateway_module_1

The Bently Nevada 190782-01 is widely recognized as the Communication Gateway Module used with 3500 racks (commonly known as the 3500/92). From my experience, it’s the straightest path to get real-time rack measurements, status, and alarms into your DCS, PLC, historians, or CMMS without juggling custom drivers. You might notice that it sits in a single 3500 rack slot and exposes Modbus (TCP and RTU) plus serial and Ethernet interfaces—simple, predictable, and usually painless to commission.

Company’s Order Placement Process and Guarantees

  • Warranty: 365 days
  • Delivery time: 1 week if in stock; no more than one month at the latest
  • Payment: 50% advance payment; full payment prior to delivery
  • Express options: FedEx, UPS, DHL

Key Features

  • Modbus connectivity (TCP and RTU) – Typically used to share 3500 rack values and alarms with DCS/PLC systems without proprietary drivers.
  • Ethernet and serial options – 10/100Base‑T Ethernet plus RS‑232/RS‑485 serial ports to match existing plant networks.
  • Rack-powered, no external PSU – Draws power from the 3500 backplane, which keeps panel wiring tidy and reduces failure points.
  • Status and alarm mapping – Provides structured Modbus registers for measurement values, OK status, and alarm conditions in most cases.
  • Front‑panel diagnostics – LEDs help technicians verify comms, power, and module health at a glance.
  • Simple slot installation – Fits a standard single‑width 3500 slot with the I/O module and terminal assembly at the rear.

Technical Specifications

Brand / Model Bently Nevada 190782-01 (Communication Gateway Module for 3500 systems)
HS Code 9032.89.0000 (Automatic regulating or controlling instruments; other)
Power Requirements Powered from 3500 rack backplane; no external power supply required
Dimensions & Weight Standard single‑slot 3500 plug‑in module form factor (fits existing 3500 racks)
Operating Temperature Typically 0 to +65 °C for installed 3500 modules (indoor, protected enclosure)
Signal Input/Output Types Data interface to 3500 backplane; external I/O as Modbus registers and status/alarm bits
Communication Interfaces 1× RJ‑45 10/100Base‑T Ethernet; RS‑232 (DB‑9) and RS‑485 (terminal) for Modbus RTU; standard baud rates up to 115.2 kbit/s
Installation Method Plug‑in module for Bently Nevada 3500 rack with rear I/O module and terminal assemblies

Application Fields

Plants that standardize on Modbus typically pick this module to let their 3500 rack talk to the control layer. It seems to be the most practical fit when you need consolidated vibration/condition data alongside process tags:

  • Oil & Gas – Compressor trains, turbines, and pumps where trip/alarm states must be mirrored to DCS and ESD logic.
  • Power Generation – Turbine protection values into plant‑wide SCADA without custom interfaces.
  • Petrochemical & Chemical – Centralized historians and maintenance systems consuming Modbus TCP.
  • Pulp & Paper / Mining – Low‑latency alarm signaling over RS‑485 to legacy PLCs.

One reliability engineer told us the switch to Ethernet Modbus via the 190782‑01 cut their “data gaps” during transient events because they no longer polled through a serial multiplexer.

Advantages & Value

  • Native 3500 compatibility – No gateways-on-gateways; direct mapping from the monitoring rack reduces integration friction.
  • Standard protocols – Modbus TCP/RTU means faster commissioning and easier long‑term support.
  • Lower lifecycle cost – Fewer external boxes and power supplies; fewer spares to manage.
  • Proven reliability – Industrial design with clear front‑panel diagnostics, helpful during outages and FAT/SAT.
  • Supportable at scale – Works in mixed networks where some units still use RS‑485 while new assets move to Ethernet.

Installation & Maintenance

  • Environment – Install in a 3500 rack inside a protective cabinet; maintain adequate ventilation and keep within the module’s temperature limits.
  • Wiring – Use shielded twisted pair for RS‑485; follow proper grounding to minimize noise. Keep Ethernet runs within specification and avoid unmanaged daisy chains.
  • Network setup – Assign fixed IPs for Modbus TCP; document register maps so DCS/PLC points are traceable during maintenance.
  • Safety – De‑energize I/O where required and observe ESD procedures when installing or removing the module.
  • Routine tasks – Periodically verify Modbus mapping, check link LEDs and error counters, back up configuration, and review firmware revision when planning rack updates.

Quality & Certifications

  • Typically meets CE requirements and is offered with UL/CSA recognition for industrial control equipment.
  • RoHS compliance is commonly available for current production units.
  • Manufacturer’s warranty practices apply; our supply is covered by a 365‑day warranty.

If you’re replacing an existing 3500/92 or adding Ethernet connectivity to a legacy rack, the 190782‑01 tends to drop in smoothly. Let me know your rack configuration and preferred protocol (Modbus TCP vs. RTU), and I can help validate slotting and register mapping ahead of time to shorten commissioning.