Description
GE DS200DCFBG1BKC – Power Distribution/Power Supply Board for Mark V Cabinets
The GE DS200DCFBG1BKC is a Mark V “power panel” board that distributes and conditions cabinet power for the control core and peripheral modules. From my experience, this board typically sits in the power section of the Mark V and provides the regulated rails and protected outputs the system relies on for steady operation. If you’re maintaining a gas/steam turbine control cabinet, this is one of those hardware pieces that keeps the rest of the rack calm and predictable.
Company’s Order Placement Process and Guarantees
- Warranty period: 365 days
- Lead time: 1 week if in stock; no more than one month at the latest
- Payment: 50% advance payment, full payment before delivery
- Express options: FedEx, UPS, DHL
Key Features
- Power distribution for Mark V – Routes cabinet AC/DC feeds to the control core and I/O, with onboard protection to minimize nuisance trips.
- Regulated low-voltage rails – Provides the stable control voltages that Mark V logic boards depend on, which typically improves noise immunity.
- Fusing and status indications – You might notice convenient test points and fuse protection that speeds up troubleshooting during outages.
- Backplane connectivity – Direct plug-in/backplane connectors reduce wiring complexity and improve serviceability.
- Form-fit for DS200 platform – Fits standard Mark V racks, making swaps straightforward during planned maintenance windows.
- Field-proven reliability – In many cases, this board has outlasted surrounding components; it’s a common spare in turbine maintenance kits.
Technical Specifications
| Brand / Model | GE / DS200DCFBG1BKC |
| Product Type | Power distribution / power supply board for Mark V |
| HS Code | 8538.90 (Parts for industrial control panels / switchgear) |
| Power Requirements | Powered from Mark V cabinet supply; accepts cabinet AC/DC feeds and provides regulated low-voltage rails (typical Mark V: 120 VAC 50/60 Hz and/or 125 VDC cabinet power) |
| Signal Input/Output Types | Backplane power rails, fused power outputs, screw/plug terminal connections; no fieldbus I/O |
| Communication Interfaces | Backplane only (no serial/Ethernet field interface) |
| Operating Temperature | 0 to 60 °C (typical cabinet environment) |
| Dimensions & Weight | Standard DS200 full-size board; fits Mark V rack footprint; typically < 1.5 kg |
| Installation Method | Panel/rack-mounted inside Mark V cabinet; plug-in/backplane connectors with standoffs; field wiring via terminal blocks |
Application Fields
This board is commonly used in:
- Gas and steam turbine control cabinets (Mark V)
- Power generation plants needing stable control power distribution
- Oil & gas compressor stations and mechanical drive packages
- Industrial facilities running legacy GE Mark V-based process control
One thing I appreciate is how it stabilizes cabinet rails during line disturbances. A maintenance lead told us, “Swapping in a verified DS200DCFBG1BKC got our rack voltages back within spec, and nuisance trips disappeared the same shift.”
Advantages & Value
- Reliability – Proven in harsh plant conditions; typically provides better uptime versus ad‑hoc power fixes.
- Compatibility – Form-fit-function for Mark V, minimizing retrofit work and downtime.
- Lifecycle support – Supports a large installed base; spares strategy is straightforward.
- Cost control – Targeted replacement of the power panel often avoids wider rack overhauls.
- Technical backing – We can assist with part identification, revision matching, and rack-level checks.
Installation & Maintenance
- Environment – Install in a clean, ventilated control cabinet. Maintain airflow; avoid dust and conductive debris.
- Safety – De-energize cabinet AC/DC feeds before handling. Observe ESD precautions; handle by edges only.
- Wiring – Verify terminal labeling and fusing. Tighten terminals to torque spec; inspect backplane connectors for bent pins.
- Commissioning – After installation, check cabinet rails (e.g., low-voltage outputs) are within expected tolerance before enabling control.
- Routine checks – Inspect fuses, connectors, and any electrolytic capacitors during outages. Clean light dust with dry, oil-free air.
- Firmware – No user firmware on this board; parameters are managed by the controller (Mark V core).
Quality & Certifications
- Industrial component for incorporation in CE/UL compliant systems (system-level compliance in most cases)
- Manufactured to OEM quality standards; RoHS status may vary by vintage/revision
- Supply chain managed under ISO 9001 practices
- Warranty: 365 days coverage
Related and Supporting Components
The DS200DCFBG1BKC is often seen alongside common Mark V boards such as DS200LDCCH1A (control core), TCQA/TCQC I/O boards, and relay/terminal modules. If you’re matching revisions or planning a preventive swap, share your current rack configuration and we’ll help check compatibility and spares coverage.