Description
Emerson 5X00273G01 Input Module – Reliable Analog Signal Acquisition for Ovation Racks
The Emerson 5X00273G01 is an Ovation-series input module designed for stable, low-noise analog signal acquisition in critical process environments. From my experience, it fits neatly into existing Ovation I/O carriers and is commonly chosen to expand analog measurement points—pressure, flow, level, analyzer outputs, or other 4–20 mA and voltage-type transmitters—without reworking the controller strategy. You might notice that it seems to be particularly forgiving with field wiring in brownfield cabinets, and in many cases it supports online replacement on supported carriers to minimize downtime.
Company’s Order Placement Process and Guarantees
- Warranty period: 365 days
- Delivery time: 1 week for in-stock items; no more than one month at the latest
- Payment: 50% advance payment; full payment prior to delivery
- Express delivery methods: FedEx, UPS, DHL
Key Features
- Ovation rack compatibility – Plug-in form factor for standard Ovation I/O carriers, simplifying expansion in existing cabinets.
- Multi-range analog inputs – Typically supports common current and voltage ranges (4–20 mA, 0–10 V), suitable for a wide mix of field transmitters.
- High-resolution conversion – 16-bit class A/D conversion in most deployments helps maintain stable and repeatable measurements.
- Channel diagnostics – Open-circuit detection for current loops and status LEDs assist with quick loop checks during commissioning.
- Backplane-powered – Draws low power from the Ovation backplane, keeping the panel power design simple.
- Noise-resilient design – Group isolation and robust filtering are commonly used to reduce electrical noise in industrial environments.
- Service-friendly – In many cases supports online replacement on compatible racks, helping keep your process running during maintenance.
Technical Specifications
| Brand / Model | Emerson 5X00273G01 |
| HS Code | 8538.90 (Parts for industrial control equipment) |
| Power Requirements | Backplane-powered, typically 5 VDC; approx. ≤5 W module consumption |
| Signal Input/Output Types | Analog Inputs (current/voltage): commonly 4–20 mA and 0–10 V ranges; 16-bit A/D; open-loop detect (4–20 mA) |
| Communication Interfaces | Ovation backplane bus to controller; no external fieldbus on the module itself |
| Installation Method | Plug-in card for Ovation I/O carrier; field wiring via terminal base/connector block |
| Operating Temperature | 0 to 60 °C (32 to 140 °F), 5–95% RH non-condensing typical |
| Dimensions & Weight | Single-width Ovation I/O module; approx. 160 × 25 × 110 mm; ~0.3 kg |
Application Fields
This module is typically used across power generation (boiler/aux, turbine balance-of-plant), water and wastewater (clarifier control, pump stations), oil and gas (wellhead, separators, tank farms), and chemicals (utility systems, batching). If you’re upgrading legacy loops to digital control within an Ovation DCS, the 5X00273G01 gives you a clean path to bring in transmitter signals without changing the control philosophy.
A maintenance engineer at a combined-cycle plant told us a simple but telling point: swapping to this card type reduced their loop-troubleshooting time because the onboard status LEDs made it obvious when a 4–20 mA line had gone open or was shorted at the marshalling panel.
Advantages & Value
- Drop-in compatibility – Designed for Ovation architecture, avoiding costly rework and revalidation.
- Stable measurement quality – High-resolution conversion with robust filtering for noisy environments.
- Reduced downtime – In most cases, online replacement on supported racks helps keep the process live.
- Lower lifecycle cost – Standardized spares strategy across your Ovation cabinets, plus simple field wiring practices.
- Technical backing – We provide configuration guidance and post-sales support for commissioning and diagnostics.
Installation & Maintenance
- Cabinet/rack – Mount on a compatible Ovation I/O carrier within a 19-inch control cabinet. Ensure adequate ventilation and maintain ambient temperatures within spec.
- Wiring – Use shielded twisted pairs for analog inputs; ground shields at a single point to minimize ground loops. Separate low-level analog from high-voltage and relay wiring.
- Loop power – For 4–20 mA instruments, supply stable 24 VDC loop power; verify polarity and burden resistance when multiple devices share the loop.
- ESD and handling – Observe ESD precautions; insert and remove the module with the carrier latched and according to site procedures.
- Routine checks – Periodically verify channel scaling, perform loop integrity tests, clean connectors if dust accumulates, and review controller diagnostics. Firmware updates (if applicable) should follow your Ovation change-management process.
Quality & Certifications
- CE and UL compliant in typical configurations
- RoHS adherence for material safety
- Manufactured under ISO 9001 quality systems
- Warranty: 365 days
Recommended Supporting Components
- Ovation I/O carrier and terminal base – Provides the backplane interface and field-term connection points for the module.
- Shielded terminal blocks or plug-in connectors – Simplify maintenance and reduce signal noise pickup.
- 24 VDC loop power supply (industrial grade) – For powering 2‑wire transmitters with low ripple and overcurrent protection.
- Shielded twisted-pair instrumentation cable – Ensures signal integrity over long cabinet-to-field runs.












Reviews