EATON PL9-C6/2-DC – 2‑Pole DC Miniature Circuit Breaker for dependable 6 A protection

Brand / ModelEATON PL9-C6/2-DC

Product TypeDC Miniature Circuit Breaker (MCB), 2‑pole, C‑curve, 6 A

HS Code8536.20 (Automatic circuit breakers)

Power RequirementsNone (self‑powered from the protected circuit)

Poles / Rated Current2 poles / 6 A

Trip CurveC (suitable for moderate inrush loads)

Operating TemperatureTypically −25 °C to +55 °C (derating may apply at higher ambient)

Dimensions & WeightApprox. 2 modules wide (~36 mm); DIN‑rail height footprint

Signal I/OLine/Load screw terminals; mechanical switch position indicator

Communication InterfacesNone

Installation Method35 mm DIN rail (EN 60715); front wiring

Categories: Tags:
contact qrcode

Need help?
Email: sales@fyplc.cn
Tel/WhatsApp: +86 173 5088 0093

Description

EATON PL9-C6/2-DC – 2‑Pole DC Miniature Circuit Breaker for dependable 6 A protectionEATON_PL9-C6-2-DC_6

The EATON PL9-C6/2-DC is a compact, DIN‑rail mounted DC miniature circuit breaker designed for small to mid‑range direct‑current loads. From my experience, it’s a sensible pick for battery banks, DC control circuits, and telecom power distribution where you want a clean, predictable trip curve and the reassurance of a well-known brand. You might notice that it follows the familiar xPole footprint, so it typically drops into standard 35 mm rails without fuss.

Company’s Order Placement Process and Guarantees

  • Warranty: 365 days
  • Delivery time: 1 week for in-stock items; no more than one month at the latest
  • Payment method: 50% advance payment, full payment for delivery
  • Express delivery: FedEx, UPS, DHL

Key Features

  • 2‑pole DC protection – Breaks both conductors in DC circuits, which is typically preferred for battery and telecom systems.
  • C‑curve tripping – C‑characteristic suits mixed loads and inrush conditions; in many cases it reduces nuisance trips on inductive loads.
  • Rated current 6 A – A practical choice for branch protection on instrumentation, control loops, and small DC feeders.
  • DIN‑rail form factor – Standard 35 mm rail mounting keeps panel integration straightforward.
  • Clear status indication – You can visually check the switch position; technicians appreciate the quick troubleshooting.
  • Panel-friendly width – Two modules (about 36 mm) help save space in dense enclosures.
  • EATON ecosystem compatibility – Works with common accessories like busbar combs and lockout tabs, simplifying multi‑circuit builds.

Technical Specifications

Brand / Model EATON PL9-C6/2-DC
Product Type DC Miniature Circuit Breaker (MCB), 2‑pole, C‑curve, 6 A
HS Code 8536.20 (Automatic circuit breakers)
Power Requirements None (self‑powered from the protected circuit)
Poles / Rated Current 2 poles / 6 A
Trip Curve C (suitable for moderate inrush loads)
Operating Temperature Typically −25 °C to +55 °C (derating may apply at higher ambient)
Dimensions & Weight Approx. 2 modules wide (~36 mm); DIN‑rail height footprint
Signal I/O Line/Load screw terminals; mechanical switch position indicator
Communication Interfaces None
Installation Method 35 mm DIN rail (EN 60715); front wiring

Application Fields

In many cases, the PL9-C6/2-DC is selected for low‑voltage DC distribution where predictable protective behavior matters more than size: battery management panels, DC control cabinets on machinery, telecom power shelves (−48 VDC), small UPS distribution, AGV/AMR charging bays, and laboratory DC rails. One customer running a compact telecom repeater cabinet told us the 2‑pole format made maintenance safer by fully isolating both conductors during service.

Advantages & Value

  • Reliable protection – C‑curve performance seems to be the “sweet spot” for mixed DC loads.
  • Panel efficiency – Narrow footprint helps keep enclosures small, which can cut cabinet costs.
  • Compatibility – Fits standard rails and works with common busbar combs and locking accessories.
  • Serviceability – Clear actuation and tool‑friendly terminals make swaps quick during downtime.
  • Procurement predictability – Eaton part numbering is consistent, so cross‑site standardization is easier.

Installation & Maintenance

  • Cabinet environment – Mount on 35 mm DIN rail inside a ventilated enclosure. Keep ambient within the specified range; consider derating at elevated temperatures.
  • Wiring – Use appropriately rated DC cables. Tighten terminals to the torque printed on the device label. For DC systems, observe polarity and follow Eaton’s wiring diagrams for 2‑pole use.
  • Coordination – Coordinate with upstream fuses/breakers to ensure selectivity. In most cases, proper upstream sizing reduces nuisance trips.
  • Safety – Isolate and verify absence of voltage before work. Lockout/tagout where required.
  • Routine checks – Periodically re‑torque terminals, clear dust, and verify mechanical operation. If firmware is used in the upstream supply or monitoring, keep that updated to maintain proper trip coordination.

Quality & Certifications

  • CE marking; RoHS compliance
  • Designed and tested to relevant IEC/EN standards for MCBs (commonly IEC/EN 60947‑2 and/or 60898‑2 for DC variants)
  • Manufacturer’s warranty: 12 months

Related Accessories (optional)

  • DIN‑rail busbar combs for multi‑circuit builds
  • Padlockable toggle lock/lockout devices for maintenance safety
  • Auxiliary status contacts (where supported) for panel indication
  • End‑stops and rail markers for tidy panel layout

If you’re standardizing multiple DC panels, this model typically strikes a nice balance of footprint and protection. One thing I appreciate is how consistently it fits alongside other xPole breakers without reworking the rail or labels.

Reviews

There are no reviews yet.

Be the first to review “EATON PL9-C6/2-DC – 2‑Pole DC Miniature Circuit Breaker for dependable 6 A protection”

Your email address will not be published. Required fields are marked *

zzfyplc_Lily

Related products