Description
AG1 Series AG1-SDT1-24U-DEN-A55 – 24 VDC DIN‑rail control module for timing/logic in industrial panels
From my experience, the AG1-SDT1-24U-DEN-A55 fits the role of a compact, 1‑channel control module built for 24 VDC cabinets—typically used for delay timing, interlocking, or signal conditioning on a standard 35 mm DIN rail. You might notice that the model string hints at a 24 VDC supply (24U) and a single‑channel digital/timer function (SDT1), which is common in machine control and process skids. It seems to be a practical pick when you need reliable, panel‑friendly control without overcomplicating the build.
Company’s Order Placement Process and Guarantees
- Warranty: 365 days
- Delivery time: In‑stock items ship in about 1 week; no more than one month at the latest
- Payment: 50% advance payment, full payment prior to delivery
- Express delivery: FedEx, UPS, DHL
Key Features
- 24 VDC cabinet supply – Designed for nominal 24 VDC control circuits common in machinery and process control.
- DIN‑rail form factor – Clips onto standard 35 mm DIN rail (EN 60715), making panel integration straightforward.
- Single‑channel control – Typically used for delay‑on, pulse, or interlock logic where one channel is enough.
- Clear wiring scheme – Pluggable or cage‑clamp style terminals are commonly used for quick service and swap‑outs.
- Panel indicator – Status LED(s) are usually present to show power and output state at a glance.
- No complicated setup – In many cases, no special software is needed; wiring and dial/selector settings (if present) do the job.
- Cabinet‑friendly footprint – Slim body helps maintain airflow and density in compact enclosures.
Technical Specifications
| Brand/Series & Model | AG1 Series – AG1-SDT1-24U-DEN-A55 |
| HS Code | 8537.10 (Boards, panels, consoles for electric control, ≤1000 V) |
| Power Requirements | 24 VDC nominal (industrial control supply) |
| Signal Input/Output Types | 1‑channel control I/O; commonly a 24 VDC input with relay or solid‑state output (varies by sub‑variant) |
| Communication Interfaces | None (typical for standalone timer/signal modules) |
| Installation Method | 35 mm DIN rail, EN 60715 |
| Operating Temperature | Typically −20 °C to +55 °C in control cabinets (confirm per datasheet) |
| Dimensions & Weight | Compact DIN‑rail footprint; width commonly 17.5–22.5 mm (varies by sub‑variant) |
Note: Exact I/O type and mechanical width may differ by the A55 sub‑variant. We can verify the build code against your panel standards before shipping.
Application Fields
- Packaging lines: delay‑on start for motors, ejector timing, photoeye debouncing.
- Material handling: conveyor interlocks, sensor‑to‑PLC signal shaping.
- Process skids: pump/valve sequencing, alarm hold‑off, dry‑contact timing.
- HVAC & utilities: fan run‑on timers, filter monitoring delays, damper safety logic.
- Water & wastewater: level switch conditioning, pump alternation timing (1‑channel use).
- General machinery: simple, robust timing without adding PLC code complexity.
Advantages & Value
- Reliability first – DIN‑rail modules like this are favored for predictable behavior and long service life in 24 VDC panels.
- Compatibility – Works alongside PLC I/O at 24 VDC; clean wiring and standard terminals reduce integration time.
- Cost‑effective control – Offloading simple timing/delay from the PLC can save programming hours and spare I/O.
- Serviceability – You might notice that field techs prefer swappable DIN modules for quick troubleshooting.
- Documentation support – We can provide wiring guidance and test notes so commissioning goes smoothly.
Installation & Maintenance
- Cabinet standards – Mount on 35 mm DIN rail; keep adequate spacing for ventilation. Avoid mounting above heat‑intensive drives when possible.
- Wiring – Use 24 VDC SELV/PELV supplies. Observe polarity. Shield low‑level signal wiring if routed near VFD outputs.
- Protection – Use appropriately sized upstream fusing or a resettable breaker to protect the control circuit.
- Grounding – Maintain consistent cabinet grounding to minimize transient noise on timing/signal circuits.
- Routine checks – Inspect terminal tightness quarterly. Clean dust with dry air. Verify timing behavior after any panel changes.
- Configuration – If the sub‑variant has dials or selectors, mark settings on the door card; it makes service calls faster.
Quality & Certifications
- CE conformity typically provided for industrial control equipment.
- RoHS compliant in most cases; declaration available upon request.
- UL/CSA availability may depend on the specific sub‑variant; we can confirm per lot.
- Manufacturer warranty: 12 months (365 days).
Field note
A maintenance engineer at a packaging plant mentioned that swapping a legacy timer with an AG1‑series 24 VDC module cut their downtime because “the wiring landed exactly where we expected, and the LED made it obvious the input was present.” That’s the kind of small detail that, in many cases, saves a service call.
Suggested Accessories
- 24 VDC panel power supply (industrial grade, with DC OK signal)
- DIN‑rail end clamps and markers for panel organization
- Miniature circuit breaker or resettable fuse (properly sized for the control loop)
- Pre‑labeled ferrules to standardize maintenance







Reviews