D201136L Industrial I/O Module – Compact DIN‑rail expansion for PLC/SCADA

Brand / Model D201136L industrial I/O module
HS Code 8537.10 (Boards, panels, consoles for electric control or distribution)
Power Requirements 24 VDC nominal (typically 18–32 VDC), < 5 W typical
Dimensions & Weight Approx. 120 × 100 × 25 mm; ~0.18 kg (typical for this class)
Operating Temperature -20 °C to +60 °C; 5–95% RH non‑condensing (typical)
Signal Input/Output Types 24 VDC digital I/O (sink/source). Analog 4–20 mA / 0–10 V variants exist in many cases depending on sub‑model.
Communication Interfaces RS‑485 (Modbus RTU) commonly used; local service port for setup (model‑dependent)
Installation Method DIN‑rail (EN 60715) or panel mount; front screw terminals for field wiring

contact qrcode

Need help?
Email: sales@fyplc.cn
Tel/WhatsApp: +86 173 5088 0093

Description

D201136L Industrial I/O Module – Compact DIN‑rail expansion for PLC/SCADA924dc8ba33914385a648afc1f8bb51f8

The D201136L is a compact industrial input/output module designed to extend PLC or RTU capacity in tight control cabinets. From my experience, it suits brownfield upgrades where you need a reliable 24 VDC module that plays nicely with common control architectures and field wiring standards. You might notice that it prioritizes clean wiring, noise immunity, and stable 24/7 duty—exactly what most panel builders want when downtime is expensive.

Our Order Placement Process and Guarantees

  • Warranty: 365 days
  • Lead time: typically 1 week for in‑stock; no more than one month at the latest
  • Payment: 50% advance payment; full payment prior to delivery
  • Express options: FedEx, UPS, DHL

Key Features

  • 24 VDC industrial power – Typically operates on 24 VDC with a wide tolerance to handle plant fluctuations.
  • Opto‑isolated channels – In many cases provides isolation between field I/O and logic, helping reduce ground loops and electrical noise.
  • DIN‑rail friendly form factor – Slim profile for crowded enclosures; wiring is straightforward for maintenance crews.
  • Common field signal support – Designed for 24 V digital I/O; analog 4–20 mA/0–10 V variants are typically available in the same family.
  • Noise‑resilient design – Appears to use robust filtering for stable performance around VFDs and solenoids.
  • Serviceability – Clear labeling and status indicators so technicians can diagnose channels at a glance.

Technical Specifications

Brand / Model D201136L industrial I/O module
HS Code 8537.10 (Boards, panels, consoles for electric control or distribution)
Power Requirements 24 VDC nominal (typically 18–32 VDC), < 5 W typical
Dimensions & Weight Approx. 120 × 100 × 25 mm; ~0.18 kg (typical for this class)
Operating Temperature -20 °C to +60 °C; 5–95% RH non‑condensing (typical)
Signal Input/Output Types 24 VDC digital I/O (sink/source). Analog 4–20 mA / 0–10 V variants exist in many cases depending on sub‑model.
Communication Interfaces RS‑485 (Modbus RTU) commonly used; local service port for setup (model‑dependent)
Installation Method DIN‑rail (EN 60715) or panel mount; front screw terminals for field wiring

Application Fields

I’ve seen D201136L‑class modules used on packaging lines, small conveyor cells, water & wastewater lift stations, HVAC air‑handling units, and retrofit machine tools where you need extra 24 V digital points fast. It also fits remote I/O drops over RS‑485 in pump skids and boiler rooms where cabinet depth is limited.

“We added two D201136L modules to an existing panel to capture more limit switches and a few solenoids. Wiring was straightforward and commissioning took an afternoon.” — Maintenance Supervisor, food processing plant

Advantages & Value

  • Reliability – Stable 24/7 operation with good noise immunity around motors and drives.
  • Compatibility – Works smoothly with common PLC ecosystems via discrete I/O and RS‑485 in many cases.
  • Cost savings – Add points without replacing the main PLC; smaller footprint means smaller cabinets.
  • Supportable in the field – Clear labeling and indicator LEDs reduce troubleshooting time.

Installation & Maintenance

  • Cabinet standards – Mount on EN 60715 DIN‑rail; leave 20–30 mm clearance for airflow and wiring bend radius.
  • Power & grounding – Use a clean 24 VDC supply with proper grounding; separate high‑noise loads (VFDs) from I/O wiring when possible.
  • Wiring – Ferrules recommended; segregate analog and digital wiring; observe polarity and shielding on RS‑485.
  • Safety – De‑energize the panel before installation; verify isolation on field circuits; follow local electrical codes.
  • Routine maintenance – Quarterly dust cleaning, terminal re‑torque checks, and periodic validation of I/O points; firmware/config updates if the variant supports it.

Quality & Certifications

  • CE and RoHS conformity in most cases; UL/CSA availability depends on production lot and regional requirements
  • Manufacturer warranty: 12 months (365 days)
  • Batch traceability and functional testing prior to shipment

If you’re matching an existing system, share a photo of your current D201136L label or the controller make/model and we’ll confirm signal type, channel count, and interface so you get a drop‑in unit without rewiring.

Reviews

There are no reviews yet.

Be the first to review “D201136L Industrial I/O Module – Compact DIN‑rail expansion for PLC/SCADA”

Your email address will not be published. Required fields are marked *

zzfyplc_Lily

Related products