Description
ABB DI830 (3BSE013210R1) – 24 VDC, 16‑Channel Digital Input Module with SOE for S800 I/O
The ABB DI830 is a 24 VDC digital input module for the S800 I/O platform, typically used with AC 800M controllers and 800xA systems. It provides 16 high‑reliability input channels and, in most cases, supports sequence‑of‑events (SOE) time stamping down to 1 ms when the system clock is synchronized. From my experience, this is the go‑to card when you need clean, fast digital state capture for trips, permissives, and alarms without overcomplicating the cabinet design.
Our Order Placement Process & Guarantees
- Warranty: 365 days standard coverage.
- Lead time: 1 week if in stock; no more than one month at the latest.
- Payment: 50% advance payment; full payment prior to delivery.
- Express shipping: FedEx, UPS, DHL—packed for industrial electronics.
- Traceable documentation: test report and packing list included, typically with module labeling photos on request.
Key Features
- 16 digital inputs at 24 VDC – A practical density for medium I/O nodes and interlock racks.
- Sequence‑of‑events (SOE) capability – Time stamping typically to 1 ms when system time is synchronized, ideal for trip analysis.
- Hot‑swap module replacement – You might notice that most S800 modules allow online replacement to minimize downtime.
- Per‑channel status LEDs – Quick troubleshooting right at the cabinet.
- Configurable input filtering – Helps tame contact bounce and noisy signals in many cases.
- S800 form factor – Plugs into standard TU8xx terminal units on DIN rail for fast installation.
- System compatibility – Works with AC 800M/800xA via the S800 ModuleBus; no extra local comms wiring on the module.
Technical Specifications
| Brand / Model | ABB DI830 (3BSE013210R1), S800 I/O Digital Input Module |
| HS Code | 8538.90 (Parts for switching/protective control apparatus) |
| Channels & Type | 16 digital inputs, 24 VDC (suitable for dry contacts or PNP field signals with external 24 V supply) |
| Input Levels (typical) | ON > ~13 VDC; OFF < ~5 VDC; input current a few mA at 24 VDC (typical for S800 DI) |
| SOE Time Stamping | Typically 1 ms with synchronized system time (800xA / AC 800M time sync) |
| Power Requirements | Powered via S800 ModuleBus (no separate logic supply). Field circuits use external 24 VDC. |
| Communication Interface | S800 ModuleBus (used with AC 800M and CI8xx interfaces; no front‑port comms on module) |
| Operating Temperature | 0 to +55 °C (typical S800 rating) |
| Dimensions & Weight | Approx. 120 × 45 × 102 mm; around 0.2 kg (S800 module housing) |
| Installation Method | Plugs into TU8xx terminal units (DIN‑rail). Group isolation to ModuleBus; wiring depends on TU type. |
Compatible Terminal Units & Accessories
- TU810V1 / TU812V1 – Standard screw or spring‑clamp terminal units for S800 DI modules.
- TU814V1 – Extended terminal unit depth where cabinet space or wiring bend‑radius is tight.
- TU830V1 / TU833 – I/O cluster terminal units commonly used when mixing DI/DO/AI on the same rail.
- Shielding kits and 24 VDC field power distribution accessories can simplify clean DI wiring in noisy panels.
Application Fields
Plants that need reliable digital state acquisition with accurate event logs typically choose the DI830. Common uses include:
- Oil & Gas and Petrochemicals – ESD inputs, permissives, valve limit switches, trip/alarm SOE.
- Power Generation & T&D – Turbine auxiliary status, breaker positions, fast interlocks.
- Water & Wastewater – Pump starts, wet‑well level switches, gate end‑stops with noise filtering.
- Metals, Pulp & Paper, and F&B – Line safety circuits, door interlocks, jam detection.
Advantages & Value
- Proven reliability – S800 modules are widely deployed; spares strategy is straightforward in most cases.
- Seamless compatibility – Works natively with AC 800M/800xA; no awkward integration overhead.
- Lower lifecycle cost – Hot‑swap design reduces downtime and maintenance labor.
- Better troubleshooting – SOE time stamps help pinpoint the exact sequence during plant upsets.
- Flexible wiring – Fits multiple TU types, so you can reuse cabinet layouts and existing rail space.
Installation & Maintenance
- Panel environment – Use a grounded, ventilated cabinet; keep ambient within 0…55 °C and avoid condensation.
- DIN‑rail & TU selection – Choose TU810V1 or TU812V1 for standard builds; maintain the ModuleBus continuity segments properly.
- Wiring practices – Provide a stable 24 VDC field supply; group commons per TU wiring; segregate DI wiring from high‑noise conductors.
- Signal conditioning – Apply the module’s input filtering for contact bounce; use suppressors on inductive loads to reduce transients.
- Hot‑swap safety – Place the controller in a safe operating mode if required by site procedures; label channel assignments before replacement.
- Routine care – Check terminal tightness during shutdowns, clean dust from ventilation paths, and verify time synchronization for accurate SOE.
Quality & Certifications
- Certifications: CE marking; UL/CSA listings and RoHS compliance are commonly applicable to S800 modules.
- Manufacturer quality: Built to ABB’s industrial standards for process automation hardware.
- Warranty: 365‑day warranty from us, covering form, fit, and function under normal use.
One thing I appreciate is how the DI830 balances speed and noise immunity. If you’re modernizing an 800xA node or adding fast interlocks, it seems to be a safe choice—especially where a clean SOE log saves hours during root‑cause analysis.







Reviews