EATON XVH-340-57CAN-1-10 – Compact 5.7-inch HMI for CANopen Machine Control
The EATON XVH-340-57CAN-1-10 is a compact operator interface designed for machine panels that need reliable visualization and fast, deterministic communication over CANopen. From my experience, this 5.7-inch HMI fits well in tight enclosures and typically pairs with CAN-based drives, sensors, or remote I/O where space and robustness matter. You might notice that it emphasizes dependable 24 V DC operation, panel-mount installation, and a straightforward connection set that keeps commissioning times short.
Company’s Order Placement Process and Guarantees
- Warranty: 365 days
- Delivery time: 1 week for in-stock items; no more than one month at the latest
- Payment: 50% advance payment; full payment prior to delivery
- Express options: FedEx, UPS, DHL
Key Features
- 5.7-inch TFT touch display – A practical size for machine doors and compact panels while remaining readable at arm’s length.
- CANopen connectivity – Integrates with CAN-based drives, valve islands, and remote I/O; ideal for deterministic field communication.
- 24 V DC industrial power – Typically 18–30 V DC input range for stable control-cabinet deployment.
- Panel-mount with robust front protection – Front side sealing usually meets IP65 when properly gasketed.
- Serial ports for legacy devices – RS-232/RS-485 are commonly used for barcode readers, small PLCs, and inverters.
- Engineering software compatibility – Works with EATON visualization toolchains (typically GALILEO / XV platform), which keeps project migration simpler.
- Designed for continuous operation – Suitable for 24/7 production lines; LED backlight technology generally improves life expectancy.
Technical Specifications
| Parameter | Details |
|---|---|
| Brand / Model | EATON XVH-340-57CAN-1-10 |
| HS Code | 8537.10 (Boards, panels, consoles for electric control, ≤1000 V) |
| Power Requirements | 24 V DC (typical 18–30 V DC), reverse-polarity protected |
| Display | 5.7-inch TFT touch panel, LED backlight |
| Operating Temperature | Typically 0…50 °C (panel front rated for industrial environments) |
| Communication Interfaces | CANopen; Serial ports (RS-232 / RS-485) for peripherals and PLC links |
| Signal I/O | No onboard discrete I/O; connects to PLCs and remote I/O via CANopen/serial |
| Installation Method | Panel mount with rear clamps; front seal typically IP65 when correctly installed |
Application Fields
This model suits compact machines and decentralized stations where CANopen is already the backbone: assembly cells, low-voltage switchgear add-ons, packaging in-feeds, test benches, and small material handling equipment. In many cases, OEMs choose it as a neat CAN visualization node next to a drive group or valve manifold—short cable runs, fewer gateways. For service teams, the 5.7-inch size is enough for diagnostics, recipes, and basic trend views without reworking cabinet cutouts.
Advantages & Value
- CAN-native integration – Reduces gateways and simplifies wiring; usually faster commissioning when your field layer is CANopen.
- Reliable platform – Eaton HMIs are known for stable 24/7 operation; firmware and tools are mature and predictable.
- Flexible connectivity – Keep legacy serial links alive while you standardize on CANopen for new devices.
- Lifecycle support – Availability of spare units and firmware support lowers long-term risk for OEM programs.
- Cost control – Right-sized 5.7-inch panel avoids overspec; power and panel cutout are already common in many cabinets.
A packaging OEM recently told us, “We replaced a gateway and saved almost a day per line during commissioning because the HMI talks CANopen directly.” That seems to be the pattern when standardizing devices on one fieldbus.
Installation & Maintenance
- Cabinet & cutout – Panel-mount on a flat, rigid surface; use the supplied gasket and even torque on clamps to maintain front sealing.
- Power & grounding – 24 V DC from a regulated supply; bond the HMI shield to cabinet earth; keep power and signal returns clean to reduce noise.
- Fieldbus wiring – For CANopen, daisy-chain twisted pair with correct 120 Ω termination at both ends; keep stubs short.
- Ventilation – Allow natural convection; avoid direct heat sources. Operating temperature is typically 0…50 °C.
- Routine care – Periodic dust removal, verify connector tightness, back up application files, and keep firmware/tools aligned with your validated version.
Supporting components you may consider: a 24 V DC DIN-rail power supply with sufficient hold-up time, properly rated CANopen termination resistors, and shielded CAN cable. Many users also carry a spare front gasket to keep IP protection after maintenance.
Quality & Certifications
- CE conformity for EMC and Low Voltage (typical for EATON HMI panels)
- UL/cUL listing for industrial control equipment (in most cases)
- RoHS-compliant construction
- Manufacturer warranty: 12 months (365 days)