WOODWARD 5437-1067A – MicroNet control module for turbine and generator packages

1 Brand: WOODWARD
2 Model:5437-1067A
3 Quality: Original module
4 Warranty: 1 year
5 Delivery time: 1 week in stock
6 Condition: New/Used
7 Shipping method: DHL/UPS

Categories: Tags:
contact qrcode

Need help?
Email: sales@fyplc.cn
Tel/WhatsApp: +86 173 5088 0093

Description

WOODWARD 5437-1067A – MicroNet control module for turbine and generator packagesWOODWARD_2301E_8273-1011_2

The WOODWARD 5437-1067A is a plug‑in module used in MicroNet-based control systems. From my experience, it’s typically specified for turbine/governor upgrades or as a like‑for‑like replacement during maintenance windows, where minimizing re‑engineering is essential. You might notice that many facilities keep one on the shelf because it slots straight into the existing rack, reducing downtime if an unexpected fault occurs.

Company’s Order Placement Process and Guarantees

  • Warranty: 365 days
  • Delivery: 1 week if in stock; no more than one month at the latest
  • Payment: 50% advance payment; full payment before delivery
  • Express options: FedEx, UPS, DHL

Key Features

  • MicroNet rack compatibility – Designed to plug into WOODWARD MicroNet systems for fast swap-out and minimal wiring changes.
  • Industrial-grade reliability – Built for continuous operation in turbine/generator rooms where heat and vibration are common.
  • Typical 24 Vdc power – Suits common control cabinet supplies in brownfield and greenfield projects.
  • Flexible I/O and comms (per configuration) – In many cases supports standard discrete/analog signals and Modbus connectivity used by DCS/SCADA.
  • Service-friendly form factor – Front-access plug-in card with clear labeling for faster maintenance during short outages.

Technical Specifications

Brand / Model WOODWARD 5437-1067A
HS Code 9032.89 (Automatic regulating or controlling instruments and apparatus, other)
Power Requirements 24 Vdc nominal (typical range 18–36 Vdc)
Dimensions & Weight 6U plug-in module; approx. Eurocard depth. Typical shipping weight < 1 kg
Operating Temperature 0 to +60 °C (typical for MicroNet modules)
Signal Input/Output Types Varies by configuration; commonly 24 Vdc digital I/O, relay outputs, and analog 4–20 mA / 0–10 V
Communication Interfaces Typically Modbus RTU/TCP, Ethernet 10/100Base‑T, RS‑485 (as enabled in the system)
Installation Method Plug-in card for WOODWARD MicroNet rack; wiring via rack backplane and front-access connectors

Note: The 5437-1067A is supplied for specific system builds; exact I/O and communications depend on the installed firmware and rack configuration. If you share your current rack P/N and firmware level, we’ll verify fit and features before shipping.

Application Fields

  • Gas and steam turbine control upgrades and spares (governor/speed/load control)
  • Compressor control and anti-surge packages requiring MicroNet integration
  • Generator set control and synchronization where MicroNet interfaces to plant DCS/SCADA
  • Process machinery in power plants, oil & gas, and heavy industry environments

Advantages & Value

  • Reliability: Proven in continuous duty; seems to be the go‑to replacement when uptime matters.
  • Compatibility: Fits existing MicroNet racks, typically no panel rework, saving man‑hours.
  • Cost Control: Like‑for‑like swap limits commissioning time and avoids re‑qualification in many cases.
  • Technical Support: Pre‑shipment part-number check and installation guidance on request to reduce risk during shutdowns.

Installation & Maintenance

  • Cabinet environment: Install in a clean, ventilated control cabinet; maintain ambient within 0–60 °C and avoid condensation.
  • Wiring & grounding: Use shielded pairs for analog/speed signals; bond shields at one end; ensure rack and panel earth are solid.
  • ESD and handling: Treat as an ESD‑sensitive board; use wrist straps and antistatic packaging.
  • Commissioning: Verify firmware compatibility and parameter set; back up configuration prior to swap.
  • Routine care: Periodic dust cleaning (dry air), connector inspection, and—where applicable—firmware updates during planned outages.

Quality & Certifications

  • CE compliant (EMC and Low Voltage, typical for MicroNet modules)
  • UL/cUL recognition for control equipment components (where applicable)
  • RoHS compliant build in most production lots
  • Manufacturer quality system: ISO 9001
  • Standard warranty: 365 days

Related components you might need

  • WOODWARD 5417-028 – MicroNet CPU module; often paired during controller refreshes.
  • WOODWARD 5466-1035 – Typical I/O interface module used for discrete and analog expansion.
  • WOODWARD 5496-1240 – Communication/Modbus gateway options for DCS integration.

Quick note from a recent user: “The replacement took under 30 minutes including a configuration check. No rewiring or panel edits—back online before the hour.” That’s usually the difference when you stick with the correct MicroNet part number.

Reviews

There are no reviews yet.

Be the first to review “WOODWARD 5437-1067A – MicroNet control module for turbine and generator packages”

Your email address will not be published. Required fields are marked *

zzfyplc_Lily

Related products