Emerson KJ3242X1-BK1 (12P4711X042) – DeltaV Analog Output HART Module for precise 4–20 mA control

1 Brand: Emerson
2 Model: KJ3242X1-BK1
3 Quality: Original module
4 Warranty: 1 year
5 Delivery time: 1 week in stock
6 Condition: New/Used
7 Shipping method: DHL/UPS

Categories: Tags:
contact qrcode

Need help?
Email: sales@fyplc.cn
Tel/WhatsApp: +86 173 5088 0093

Description

Emerson KJ3242X1-BK1 (12P4711X042) – DeltaV Analog Output HART Module for precise 4–20 mA controlEmerson_KJ3242X1-BK1_12P4711X042_3Emerson_KJ3242X1-BK1_12P4711X042_4

The Emerson KJ3242X1-BK1 (12P4711X042) is a DeltaV S-series analog output module engineered for reliable 4–20 mA control, typically with HART capability for device diagnostics and configuration. From my experience, this module is a go-to when you need stable, noise-resistant current outputs to drive control valves, I/P converters, VFD analog references, or other final control elements—without babysitting the loop day in and day out. You might notice that it slips into existing DeltaV S-series carriers seamlessly, which keeps changeovers fast and downtime short.

Order Placement Process and Guarantees

  • Warranty: 365 days
  • Delivery: 1 week for in-stock; no more than one month at the latest
  • Payment: 50% advance payment; full payment prior to delivery
  • Express options: FedEx, UPS, DHL

Key Features

  • 4–20 mA analog outputs – Stable, low-noise current outputs suited for valve positioners, I/Ps, and drives.
  • HART pass-through (typical) – Enables device diagnostics and configuration from the host, saving field trips.
  • DeltaV S-series hot-swappable design – Replace the module under power in most cases for quick maintenance.
  • Channel diagnostics – Loop monitoring and status reporting help pinpoint wiring issues faster.
  • Redundancy-ready architecture – Works with DeltaV redundant I/O strategies to boost availability.
  • Per-channel configuration – Scale ranges and alarms per loop to match instrument requirements.
  • Tight DeltaV integration – Proven compatibility with S-series carriers and engineering tools.

Technical Specifications

Brand / Model Emerson DeltaV / KJ3242X1-BK1 (12P4711X042)
HS Code 8537.10 (Programmable controllers and related control assemblies)
Power Requirements Supplied via DeltaV S-series backplane, nominal 24 VDC; module power draw typically < 5 W
Dimensions & Weight S-series plug-in module form factor; approx. compact module size suitable for standard DeltaV I/O carriers
Operating Temperature Typically 0 to 55 °C (consult installed-site specification for exact limits)
Signal I/O Types Analog Outputs: 4–20 mA, HART-capable in many cases; multi-channel module
Communication Interfaces DeltaV proprietary backplane; HART pass-through to host asset management
Installation Method Plug-in to DeltaV S-series I/O carrier; field wiring via terminal block assemblies inside a control cabinet
Field note: A maintenance lead from a midstream facility told us the KJ3242X1-BK1 “cleaned up our output noise on two troublesome valve loops—no rewiring, just drop-in on the carrier.”

Application Fields

  • Oil & Gas – Valve positioners, I/P transducers, and wellhead control loops where stable 4–20 mA is critical.
  • Chemicals & Petrochemicals – Reactor control outputs, dosing skid actuation, and pump speed references.
  • Power Generation – Turbine auxiliary control, feedwater valve control, and burner management analog outputs.
  • Water & Wastewater – Blower/VFD analog references, chemical dosing outputs, and remote actuator control.
  • Pharma & Food – CIP/SIP skid control and precise flow/pressure regulation with device feedback via HART.

Advantages & Value

  • Reliability that fits existing DeltaV racks – Less risk during swaps; minimal re-engineering.
  • Compatibility that reduces commissioning time – Native integration and diagnostics usually shorten loop checks.
  • Lifecycle savings – HART pass-through helps cut site visits and speeds device troubleshooting.
  • Supportable spares strategy – Common S-series footprint helps standardize inventory in multi-unit sites.

Installation & Maintenance

  • Cabinet and environment – Mount on DeltaV S-series carrier within a ventilated, dry control cabinet (typically IP54/NEMA 12 or better). Keep ambient within spec for thermal margin.
  • Wiring – Use twisted, shielded pair for analog loops; land shields at a single point. Verify loop polarity and power (if driving active devices versus passive I/Ps).
  • Power & grounding – Maintain clean 24 VDC to the carrier; bond cabinet ground properly to reduce analog noise.
  • Safety – De-energize field loops when practical; observe ESD precautions when handling the module.
  • Routine checks – Periodic loop health verification, HART device status review, and output trim/calibration checks as per site SOP.
  • Firmware/Configuration – Keep the DeltaV revision aligned with plant standards; back up configurations before module replacement or upgrades.

Quality & Certifications

  • CE and UL/CSA compliant for industrial control equipment (typical for DeltaV S-series)
  • RoHS-conforming construction in many cases
  • Manufacturer’s warranty: 365 days via our supply terms
Supporting components you may need: DeltaV S-series I/O carrier, matching terminal block/field-wiring assembly, and cabinet DIN rail hardware. If you’re standardizing spares, pairing this module with a spare carrier and terminals usually shortens recovery time during an outage.

Reviews

There are no reviews yet.

Be the first to review “Emerson KJ3242X1-BK1 (12P4711X042) – DeltaV Analog Output HART Module for precise 4–20 mA control”

Your email address will not be published. Required fields are marked *

zzfyplc_Lily

Related products