Schneider Electric Modicon Quantum 140ACI04000 – Analog Current Input Module for 0–20 mA / 4–20 mA Loops

1 Brand: Schneider Electric
2 Model: 140ACI04000
3 Quality: Original module
4 Warranty: 1 year
5 Delivery time: 1 week in stock
6 Condition: New/Used
7 Shipping method: DHL/UPS

contact qrcode

Need help?
Email: sales@fyplc.cn
Tel/WhatsApp: +86 173 5088 0093

Description

Schneider Electric Modicon Quantum 140ACI04000 – Analog Current Input Module for 0–20 mA / 4–20 mA Loops140aci04000_schneider_analog_input_module_4140aci04000_schneider_analog_input_module_3

The Schneider Electric Modicon Quantum 140ACI04000 is an analog current input module designed for process-grade 0–20 mA and 4–20 mA signals. From my experience, it’s a straightforward way to bring multiple current loops into a Quantum system without adding external signal conditioners. It slots directly into a 140XBPxxx backplane and talks to your 140CPU series controller over the Quantum bus—no extra cabling tricks required. You might notice that it typically pairs well with plant-standard transmitters (pressure, flow, level, pH) and stability is solid in most cases when shielded cabling and proper grounding are used.

Order Placement Process and Guarantees

    • – Warranty period: 365 days
    • – Delivery time: 1 week for in-stock; no more than one month at the latest
    • – Payment: 50% advance payment; full payment before delivery
    – Express delivery: FedEx, UPS, DHL

Key Features

  • 0–20 mA / 4–20 mA support – Handles standard process currents, so it drops into most brownfield sites smoothly.
  • Quantum backplane integration – Plugs into 140XBP racks and communicates via the Quantum bus to 140CPU controllers, keeping wiring tidy.
  • Multi-channel design – Consolidates multiple loops on one module, which typically saves rack space and reduces per-point cost.
  • Galvanic isolation – Input-to-backplane isolation helps reduce noise and ground-loop headaches in mixed-signal cabinets.
  • Diagnostics through the CPU – Channel status and faults are readable from the PLC, which simplifies troubleshooting.
  • Conformal-coated option available – The 140ACI04000C variant is commonly used in harsher environments.
  • Field-friendly terminal block – Removable front terminal strip makes loop wiring and maintenance more practical.

Technical Specifications

Brand / Model Schneider Electric / 140ACI04000 (Modicon Quantum)
Product Type Analog Current Input Module (PLC I/O)
HS Code (reference) 853890 (Parts for industrial control equipment)
Power Requirements Backplane-powered (5 VDC via Modicon Quantum rack)
Operating Temperature Typically 0 to 60°C (32 to 140°F), non-condensing environment
Signal Input Types Analog current inputs for 0–20 mA and 4–20 mA transmitters; shielded twisted-pair recommended
Communication Interfaces Quantum backplane bus (no front-mounted Ethernet/serial ports)
Installation Method Rack-mounted, single-slot module for 140XBPxxx backplanes; front removable terminal block

Application Fields

The 140ACI04000 is used across process and hybrid plants where 4–20 mA is the lingua franca. Typical deployments include:

  • Water & wastewater – Flow, pressure, and level transmitters tied into Quantum SCADA nodes.
  • Oil & gas skids – Compact rack builds that need stable current loops for pressure/temperature while keeping wiring simple.
  • Food & beverage – Clean cabinet installs where repeatable analog acquisition matters for batching and CIP control.
  • Power & utilities – Turbine auxiliaries and BOP signals brought into legacy Quantum systems.
  • Chemicals & pharma – Analog loops for dosing, pH, and conductivity with channel diagnostics through the PLC.

A maintenance supervisor recently mentioned that swapping to this module on an existing 140XBP rack “stabilized two noisy loops” after proper grounding and cable segregation—seems to be a common result when shielding is done right.

Advantages & Value

  • Reliability in the field – Built for continuous-duty operation; less drift than ad‑hoc signal adapters in many cases.
  • Compatibility – Works seamlessly with 140CPU series and standard Quantum engineering tools, reducing project risk.
  • Lifecycle practicality – A direct fit for existing Quantum racks, so retrofits avoid costly panel rework.
  • Cost control – Multi-loop density and easy wiring cut install hours and spares holding costs.
  • Support – Technical guidance on rack loading, wiring, and loop checks—keeps commissioning smoother.

Installation & Maintenance

  • Cabinet & rack – Mount in a properly grounded enclosure with a Schneider 140XBPxxx backplane and a suitably sized 140CPS power supply. Provide ventilation; avoid high-vibration zones.
  • Wiring – Use shielded twisted-pair for 4–20 mA loops. Land shields at one end only (typically at the cabinet ground). Keep analog separate from high-voltage and high-frequency cables.
  • Loop power – Supports loop-powered and externally powered transmitters. Verify transmitter power supply sizing and polarity before energizing.
  • Commissioning – Validate each channel with a loop calibrator at 4, 12, and 20 mA. Check channel scaling in the PLC logic.
  • Routine care – Periodically re-torque terminals, inspect for corrosion, and clean dust with dry air. Review PLC firmware release notes; while the module itself has no user firmware, PLC updates can improve diagnostics.
  • Safety – De-energize field loops before changes. If performing live work, follow site LOTO and use a current-limited calibrator.

Supporting Components & Typical Pairings

  • Backplanes: 140XBP01600 / 140XBP01000 (choose slot count based on I/O density).
  • Power supplies: 140CPS11420 or 140CPS12420 (size per rack load; I/O is backplane-powered).
  • CPUs: 140CPU65150 / 140CPU67160 and similar, depending on application size.
  • Terminal accessories: 140XTS series removable terminal strips for clean field terminations.
  • Conformal-coated variant: 140ACI04000C for harsher environments.

Quality & Certifications

  • Certifications: CE, UL; RoHS-compliant materials in most production runs.
  • Manufacturing quality: Produced under ISO 9001 quality systems.
  • Warranty: 365 days (coverage for workmanship and functional performance under normal use).

Reviews

There are no reviews yet.

Be the first to review “Schneider Electric Modicon Quantum 140ACI04000 – Analog Current Input Module for 0–20 mA / 4–20 mA Loops”

Your email address will not be published. Required fields are marked *

zzfyplc_Lily

Related products