ABB DSDP170 (57160001-ADF) – System I/O Distribution/Termination Board for Advant DCS

1 Brand:ABB
2 Model:  DSDP170 (57160001-ADF)
3 Quality: Original module
4 Warranty: 1 year
5 Delivery time: 1 week in stock
6 Condition: New/Used
7 Shipping method: DHL/UPS

contact qrcode

Need help?
Email: sales@fyplc.cn
Tel/WhatsApp: +86 173 5088 0093

Description

ABB DSDP170 (57160001-ADF) – System I/O Distribution/Termination Board for Advant DCSabb_dsdp170_57160001-adf_pulse_counting_board_3-1abb_dsdp170_57160001-adf_pulse_counting_board_2-1

The ABB DSDP170, ordering code 57160001-ADF, is a spare-part board widely used in ABB Advant-based DCS installations as a distribution/termination interface for process I/O. In many cases it sits between the field wiring and the controller/remote I/O stack, helping route signals and power in a clean, serviceable way. One thing I appreciate is how it tends to keep legacy Advant I/O stations running with minimal rewiring—especially helpful during phased upgrades or quick-change maintenance windows.

From my experience, the DSDP170 is selected when teams need form-fit-function replacement inside existing Advant stations, maintaining compatibility with paired digital and analog I/O modules. You might notice that it’s designed to be backplane powered and doesn’t require separate field supply beyond what the I/O station already provides, which typically simplifies cabinet design and reduces points of failure.

Order Placement Process and Guarantees

  • Warranty: 365 days
  • Delivery: 1 week for in‑stock items; no more than one month at the latest
  • Payment: 50% advance payment, full payment prior to delivery
  • Express options: FedEx, UPS, DHL

Typical workflow: you share the required quantity and site details → we confirm exact revision/compatibility → proforma invoice issued → advance payment received → outbound testing and packing → shipment booking and tracking shared.

Key Features

  • Advant I/O distribution and termination: Designed to route field signals within ABB Advant DCS stations, aiding clean wiring and fast service.
  • Backplane powered: Typically powered from the system backplane, avoiding extra external supplies and reducing wiring complexity.
  • Compatibility-focused design: Intended as a form-fit replacement in many Advant setups using matched digital/analog I/O modules.
  • Serviceable layout: Clear terminal mapping supports faster swaps and simplifies troubleshooting during planned shutdowns.
  • Robust build for industrial cabinets: Components and PCB layout emphasize cabinet reliability and EMI/EMC resilience in most cases.

A maintenance supervisor from a chemical plant told us their team swapped a DSDP170 during a night shift and had the line back up in under an hour—no rewiring beyond terminal move-and-mark.

Technical Specifications

Brand / Model ABB DSDP170 (57160001-ADF)
Product Type I/O distribution / termination board for Advant DCS stations
HS Code 853890
Power Requirements Backplane powered (supplied by the Advant I/O station)
Signal I/O Types Field signal termination and distribution for paired digital/analog I/O modules (channel count depends on connected modules)
Communication Interfaces Advant system backplane; no external serial/Ethernet ports on the board
Installation Method Rack/slot installation within ABB Advant I/O station; cabinet mounting per ABB guidelines

Application Fields

The DSDP170-57160001-ADF is typically found in:

  • Refining and petrochemical units where legacy Advant I/O remains in service
  • Pharmaceutical batch lines requiring orderly field wiring and validated change control
  • Pulp and paper mills with staged migration from Advant to newer ABB platforms
  • Power and utilities balance-of-plant cabinets where downtime windows are tight

Advantages & Value for Procurement

  • Continuity of operation: Keeps existing Advant I/O stations running, reducing retrofit scope and risk.
  • Compatibility and form-fit: Appears to be designed for direct replacement in many Advant cabinets, limiting design changes.
  • Lower lifecycle cost: Minimizes engineering and field wiring labor versus a wholesale I/O platform swap.
  • Tested spares support: We can arrange pre-shipment functional checks and provide traceable test reports when requested.

Installation & Maintenance

  • Cabinet environment: Install in a clean, ventilated control cabinet; follow ABB grounding and shielding practices to limit EMI.
  • Mounting: Seat the board firmly in its designated station slot; check backplane connector engagement before power-up.
  • Wiring: Use correctly sized, ferrule-terminated conductors; maintain separation between signal and power wiring; label terminals for future service.
  • Safety: De-energize the station; observe ESD precautions; verify isolation before handling field conductors.
  • Routine care: Periodic visual inspection for loose terminals and dust; gentle dry-air cleaning; no user firmware on this board—backup the station configuration as standard practice.

Quality & Certifications

  • Certifications: ABB products of this class are typically CE marked; many builds comply with RoHS and are produced under ISO 9001 quality systems. UL applicability depends on the complete cabinet/system listing.
  • Manufacturer warranty: Standard ABB terms may apply in original system supply.
  • Our coverage: 365-day warranty on the supplied unit as stated above.

Commonly Paired Components (for planning)

To help with spares planning, teams often check stock on related Advant I/O items at the same time:

  • DSDI series – digital input modules used in Advant stations
  • DSDO series – digital output modules for discrete control
  • DSAI series – analog input modules for process signals
  • Advant controllers/backplanes – to confirm slot and revision compatibility during replacement

If you can share your existing station type and any label photos of the installed board, we can double-check the 57160001-ADF revision against your system before shipment. That little step usually prevents surprises onsite.