BENTLY NEVADA 330500-02-00 Velomitor – Piezo-velocity sensor for reliable rotating machinery vibration monitoring

1 Brand: BENTLY NEVADA
2 Model: 330500-02-00
3 Quality: Original module
4 Warranty: 1 year
5 Delivery time: 1 week in stock
6 Condition: New/Used
7 Shipping method: DHL/UPS

contact qrcode

Need help?
Email: sales@fyplc.cn
Tel/WhatsApp: +86 173 5088 0093

Description

BENTLY NEVADA 330500-02-00 Velomitor – Piezo-velocity sensor for reliable rotating machinery vibration monitoring330500-00-02-1-2

The BENTLY NEVADA 330500-02-00 is part of the Velomitor family, a rugged piezoelectric velocity transducer used to measure machine casing vibration on pumps, fans, motors, compressors, and gearboxes. From my experience, this model is favored where a direct velocity output simplifies wiring into existing monitors or PLCs. You might notice that it’s typically paired with Bently Nevada 3500 or 1900/65 monitors, but it also works nicely with standard IEPE/ICP signal inputs on third‑party systems.

Our Order Placement Process and Guarantees

  • Warranty: 365 days
  • Lead time: typically 1 week if in stock; no more than one month at the latest
  • Payment: 50% advance payment; full balance prior to delivery
  • Express options: FedEx, UPS, DHL

Key Features

  • Velocity output (IEPE/ICP type): Direct mV/(in/s) output reduces the need for external integration and speeds up commissioning.
  • Typical sensitivity ~100 mV/in/s (≈3.94 mV/mm/s): A widely supported scaling that most condition monitoring systems can read without custom firmware.
  • Industrial frequency band: Designed for machine casing vibration in the ~10–1000 Hz range commonly used for rotating equipment health.
  • Rugged stainless-steel housing: Built for plant environments with good resistance to oil mist, dust, and temperature swings.
  • Stud mounting: A solid mechanical path (usually 1/4‑28 UNF) gives more repeatable readings than adhesive pads in many cases.
  • Flexible system compatibility: Works with BENTLY NEVADA 3500/42M and 1900/65A, and most PLC/DCS/CM systems that accept 2‑wire IEPE sensors.
  • Variant clarity: The “‑02‑00” option typically denotes a specific mounting/connector configuration; we help verify the exact build against your datasheet before shipping.

Technical Specifications

Item Specification
Brand / Model BENTLY NEVADA 330500-02-00 (Velomitor series)
HS Code 9031.80 (measuring/checking instruments, other)
Power Requirements IEPE constant‑current drive, typically 2–10 mA with 18–30 VDC compliance
Output / Sensitivity Dynamic velocity, nominal ~100 mV/in/s (≈3.94 mV/mm/s)
Frequency Response Suitable for rotating equipment bands (commonly around 10–1000 Hz for general machinery monitoring)
Operating Temperature Typically −54 to +121 °C (−65 to +250 °F)
Signal Input/Output Types 2‑wire IEPE (ICP) constant‑current excitation; single‑ended dynamic voltage output
Communication Interfaces None (analog sensor output)
Installation Method Rigid stud mounting on machine casing; “‑02‑00” typically defines a specific connector/exit style—confirm drawing prior to order
Dimensions & Weight Compact cylindrical body; approx 28 mm diameter × 60–70 mm height; ~120 g (typical for this series)
Housing / Materials Stainless‑steel housing, industrial grade sealing

Application Fields

Commonly used on balance‑of‑plant rotating assets and critical machinery:

  • Pumps, fans, blowers, and motors (casing vibration trending and alarm)
  • Gearboxes and belt drives (fault detection around running speed and harmonics)
  • Compressors and small steam/gas turbine auxiliaries where velocity is the preferred metric
  • Refineries, chemical plants, steel mills, power generation, and water/wastewater facilities

A maintenance engineer from a mid‑stream facility told us the Velomitor “seems to be the least fussy” on their outdoor pump skids—especially with long cable runs into a shared junction box—because the IEPE standard keeps the wiring straightforward.

Advantages & Value

  • Reliability: Proven construction for harsh plants; fewer false alarms when properly mounted and biased.
  • Compatibility: Direct tie‑in to BENTLY NEVADA 3500/1900 monitors and most third‑party IEPE inputs—saves interface hardware.
  • Cost efficiency: Velocity output reduces processing complexity; often lowers total installed cost compared with accelerometer + integrator setups.
  • Technical support: We help confirm the “‑02‑00” build options (orientation, connector/cable style) against your machine drawings before shipment.

Installation & Maintenance

  • Mounting: Use a clean, flat, machined pad; stud mount (typically 1/4‑28 UNF). Apply manufacturer‑recommended torque to ensure a rigid path.
  • Wiring: Route IEPE cabling away from high‑current lines; maintain shield continuity; keep connectors dry and properly strain‑relieved.
  • Environment: Suitable for most indoor/outdoor industrial areas. For washdown or hazardous areas, confirm the exact 330500‑02‑00 configuration and approvals.
  • Commissioning: Verify IEPE bias (usually ~10–14 VDC at the receiver), check sensitivity scaling (100 mV/in/s), and perform a bump test where possible.
  • Routine care: Re‑torque mounting annually, inspect connectors and cable jackets, and schedule calibration every 1–2 years depending on criticality.
  • Firmware/monitor updates: If used with digital monitors (e.g., 3500/42M), keep monitor firmware current and document channel configuration.

Quality & Certifications

  • Manufacturer quality systems typically aligned with ISO 9001
  • CE conformity and RoHS compliance are commonly available for Velomitor series
  • Manufacturer’s standard warranty is generally 1 year; we provide a 365‑day warranty on supply

Helpful Accessories & Compatibility

  • Mounting studs and adapters (e.g., 1/4‑28 UNF to M8) to match your machine pad
  • Magnetic mounting base for temporary route measurements (commissioning/testing)
  • IEPE‑rated extension cables and sealed connectors for outdoor runs
  • Compatible monitoring: BENTLY NEVADA 3500/42M dynamic channels, 1900/65A monitors, and most PLC/DCS analog IEPE input cards

One thing I appreciate is how quickly teams can retrofit these onto existing machine pads. If you can send a quick photo or the outline drawing, we’ll confirm the “‑02‑00” orientation/connector so it lands correctly the first time.