Honeywell 51400993-100 – I/O Termination Assembly for Experion/TDC I/O Wiring

1 Brand: Honeywell
2 Model: 51400993-100
3 Quality: Original module
4 Warranty: 1 year
5 Delivery time: 1 week in stock
6 Condition: New/Used
7 Shipping method: DHL/UPS

contact qrcode

Need help?
Email: sales@fyplc.cn
Tel/WhatsApp: +86 173 5088 0093

Description

Honeywell 51400993-100 – I/O Termination Assembly for Experion/TDC I/O Wiring51400993-100

The Honeywell 51400993-100 is an I/O termination/field termination assembly used in Honeywell DCS cabinets (Experion PKS / legacy TDC3000 environments) to land field wiring cleanly and connect it to the associated I/O module. From my experience, this part is typically chosen when teams want a dependable, drop-in termination board that keeps marshalling simple and minimizes rework during maintenance.

Order Placement Process and Guarantees

  • Warranty: 365 days
  • Delivery: 1 week for in-stock items; no more than one month at the latest
  • Payment: 50% advance payment; full payment before delivery
  • Express delivery: FedEx, UPS, DHL

Key Features

  • Field termination for Honeywell I/O – Provides a tidy landing point for field cables and routes signals to the selected I/O module via system cabling.
  • Stable wiring under industrial loads – Screw-terminal style connections are designed to reduce loosened contacts from vibration in most cabinets.
  • Fast swap and maintenance – You might notice that the board layout makes channel tracing and loop checks more straightforward during shutdowns.
  • System-compatible cabling – Typically mates to Honeywell I/O through standard ribbon or system harness, helping avoid custom adapters and extra downtime.
  • Cabinet-ready footprint – Fits standard Honeywell marshalling/processor cabinets; DIN-rail or panel mounting is common depending on the enclosure setup.

Technical Specifications

Brand / Model Honeywell 51400993-100
HS Code 8538.90 (Parts suitable for use with industrial control/switchgear of 8537)
Power Requirements Passive termination board; no separate power input (draws negligible power via I/O/system interface)
Dimensions & Weight Board-level footprint used in Honeywell I/O bays; typically around 250 × 100 × 30 mm; under 0.5 kg (varies slightly by production run)
Operating Temperature 0 to +55 °C typical; 5–95% RH non-condensing (cabinet environment)
Signal Input/Output Types Termination for DCS field signals; supports the paired module’s signal type (e.g., analog or discrete), with screw terminals for field wiring and system cable to I/O
Communication Interfaces System ribbon/harness to the associated I/O module; field-side screw terminals; channel labeling for loop identification
Installation Method DIN-rail or panel-mount inside DCS cabinet/marshalling panel; follow Honeywell cabinet layout and earthing practices

Note: The 51400993-100 is part of Honeywell’s I/O termination ecosystem. Exact channel count and signal specifics depend on the paired I/O module and wiring kit; if you share your module type, we can confirm the exact fit-up.

Application Fields

  • Oil & Gas and Petrochemical – Reliable field loop termination in harsh environments, especially where quick loop isolation is needed during turnarounds.
  • Chemicals and Specialty Materials – Tidy wiring for mixed analog/discrete signals in batching and continuous units.
  • Power Generation – Stable terminations in turbine auxiliaries, water treatment skids, and BOP systems.
  • Pharmaceuticals & Food – Clean cabinet layouts that make validation and traceability easier.
  • Water/Wastewater – Straightforward marshalling with low maintenance demand.

Advantages & Value

  • Reliability in the cabinet – Solid terminal hardware that typically holds up well under vibration and temperature cycling.
  • Compatibility with Honeywell ecosystems – Designed for Experion/TDC I/O; avoids ad-hoc adapters and undocumented wiring.
  • Serviceability – Clear channel markings reduce troubleshooting time during loop checks or I/O card swaps.
  • Procurement confidence – Stable part number, strong installed base, and straightforward logistics help keep project schedules predictable.

Installation & Maintenance

  • Environment – Mount in a clean, ventilated cabinet; maintain clearance for wiring bend radius and label visibility.
  • Grounding & shielding – Follow Honeywell grounding scheme; bond cable shields at the recommended end to reduce noise pickup.
  • Wiring – Torque terminals per spec; segregate low-level analog from high-voltage conductors; use ferrules where applicable.
  • Safety – De-energize loops before changes; verify isolation when working in mixed DI/DO/AI marshalling areas.
  • Routine checks – Tighten terminals during scheduled outages; inspect for discoloration or loosened screws; update cabinet drawings when reallocating channels.

Quality & Certifications

  • Typical compliance: CE and UL/CSA for control cabinet components (varies by build year and region).
  • Manufacturing standards: Produced under Honeywell’s quality system; documentation and labeling support traceability.
  • Warranty: 12 months (365 days) from delivery.

Real-world note: A maintenance lead at a Gulf Coast chemical plant told us they swapped in 51400993-100 units as part of a phased cabinet refresh. The biggest win seemed to be faster loop tracing—less time with the multimeter, more time closing out punch-list items.

If you share the exact I/O card type and cabinet layout, we can verify the specific cable set and termination style to ensure it’s a clean, same-day fit.

Reviews

There are no reviews yet.

Be the first to review “Honeywell 51400993-100 – I/O Termination Assembly for Experion/TDC I/O Wiring”

Your email address will not be published. Required fields are marked *

zzfyplc_Lily