YOKOGAWA ADV169-P00 – Interface/Communication Module for CENTUM-System Nodes

1 Brand: YOKOGAWA
2 Model: ADV169-P00
3 Quality: Original module
4 Warranty: 1 year
5 Delivery time: 1 week in stock
6 Condition: New/Used
7 Shipping method: DHL/UPS

Categories: Tags:
contact qrcode

Need help?
Email: sales@fyplc.cn
Tel/WhatsApp: +86 173 5088 0093

Description

YOKOGAWA ADV169-P00 – Interface/Communication Module for CENTUM-System NodesADV169-P00

The YOKOGAWA ADV169-P00 is a plug-in interface module typically used inside CENTUM-family control nodes and I/O units. From my experience, it’s chosen when you need a stable backplane communication card with diagnostics, clean integration, and long lifecycle support. You might notice that it’s designed as a system module rather than a field I/O card—no direct analog or digital terminals—so its role is to keep the node communicating reliably with the system bus.

Our Order Placement Process and Guarantees

  • Warranty: 365 days
  • Delivery: 1 week when in stock; no more than one month at the latest
  • Payment: 50% advance payment; full payment before delivery
  • Express shipping: FedEx, UPS, DHL

Key Features

  • Backplane communication role – Functions as a system interface module; no direct field wiring, which keeps cabinet layouts tidy.
  • Diagnostics and status LEDs – Quick visual checks reduce troubleshooting time during shift handovers.
  • Hot-swap capability (system dependent) – In many cases, maintenance teams can replace the module online within a redundant setup.
  • Fits standard Yokogawa node units – Designed for plug-in installation in CENTUM node/chassis environments.
  • Stable long-term availability – Yokogawa’s lifecycle support typically ensures consistent spares planning.
  • Firmware compatibility by suffix – Suffix “P00” helps identify revision; we usually verify against your controller and node revision before shipping.

Technical Specifications

Brand / Model YOKOGAWA ADV169-P00
HS Code 8538.90 (Parts for control panels/apparatus)
Power Requirements Supplied via node backplane; node input typically 24 VDC (no separate field supply on the module)
Operating Temperature 0 to 55°C (typical industrial cabinet conditions)
Signal I/O Types None (communication/interface module; no direct field I/O)
Communication Interfaces Proprietary Yokogawa system bus via backplane (node-family dependent)
Dimensions & Weight Plug-in card form factor; typically < 0.5 kg, fits standard node/chassis slot
Installation Method Plug-in to Yokogawa node unit/chassis; node mounted on DIN rail or panel

Application Fields

This module is commonly applied in DCS nodes for process industries where stable backplane communications matter more than channel density:

  • Refining and petrochemicals – unit control where redundant communication paths are standard practice.
  • Chemicals and specialty batch – reliable node connectivity into recipe or S88 layers.
  • Power generation and utilities – continuous operations with tight maintenance windows.
  • Pharmaceuticals – controlled environments and validated systems where stable revision control matters.
  • Pulp & paper / water & wastewater – long service life expectations and simple spare strategy.

“We swapped in ADV-series interface cards during a scheduled two-hour window. One thing I appreciate is the clear LED status—cut our loop checks by half.” — Maintenance Supervisor, chemical plant

Advantages & Value

  • Reliability – Stable backplane comms with predictable behavior under load; seems to be very forgiving in typical cabinet temperatures.
  • Compatibility – Matches Yokogawa node form factor; we validate “P00” suffix compatibility against your system revision before shipping.
  • Cost control – Straightforward replacement keeps downtime costs in check; no rewiring since it’s a system card.
  • Technical support – Pre-shipment testing, pictures on request, and documentation to align with your MOC procedures.

Installation & Maintenance

  • Cabinet & environment – Install in a clean, ventilated control cabinet. Maintain clearance for airflow and easy front access.
  • Wiring – No field I/O wiring to the card. Ensure node power (typically 24 VDC) is stable and properly fused.
  • Handling – Observe ESD precautions. If not working in a redundant/hot-swap configuration, power down the node before insertion/removal.
  • Checks – Verify LEDs and system diagnostics after installation. Confirm recognition in the engineering console.
  • Routine care – Annual dust cleaning, connector reseat checks, and firmware revision alignment during planned outages.

Quality & Certifications

  • CE and RoHS compliance (typical for Yokogawa system modules)
  • UL/cUL recognition in many cases (confirm per batch if required for site approval)
  • Manufacturer’s warranty normally supported by our 365-day coverage