Yokogawa ADV551-P50D5A00 – Field I/O Module for CENTUM VP/CS Series Remote I/O

1 Brand: Yokogawa
2 Model: ADV551-P50D5A00
3 Quality: Original module
4 Warranty: 1 year
5 Delivery time: 1 week in stock
6 Condition: New/Used
7 Shipping method: DHL/UPS

contact qrcode

Need help?
Email: sales@fyplc.cn
Tel/WhatsApp: +86 173 5088 0093

Description

Yokogawa ADV551-P50D5A00 – Field I/O Module for CENTUM VP/CS Series Remote I/OADV551-P50D5A00-1

The Yokogawa ADV551-P50D5A00 is part of Yokogawa’s field I/O family used with CENTUM VP/CS control systems. From my experience, this module is typically specified as a drop‑in spare or capacity expansion in existing FIO nodes, where keeping the same revision code matters for seamless compatibility. If you’re standardizing your plant spares, this model number gives you a safe match for many in-service cabinets without requalifying the I/O island.

Our Order Placement Process and Guarantees

  • Warranty: 365 days
  • Lead time: 1 week if in stock; no more than one month at the latest
  • Payment: 50% advance payment, full payment prior to delivery
  • Express options: FedEx, UPS, DHL

Key Features

  • Designed for Yokogawa FIO-based systems – Suits CENTUM VP/CS remote I/O architectures in many cases, making it a practical like-for-like replacement.
  • Backplane-powered module – Draws power from the Yokogawa I/O base; no separate field supply to the card itself, which simplifies cabinet wiring.
  • Revision-coded build (P50D5A00) – You might notice that Yokogawa sub-codes help match firmware/hardware generations for hassle-free interchangeability.
  • Front-access status indication – Typical LED/status visibility lets maintenance quickly identify module health without opening field terminations.
  • Modular wiring via terminal board – Field connections remain on the terminal board, so module swaps are faster and reduce downtime.
  • Stable operation in control-room environments – Built for continuous duty in DCS cabinets where reliability and noise immunity are expected.

Technical Specifications

Brand / Model Yokogawa ADV551-P50D5A00
HS Code 8538.90 (Parts suitable for the apparatus of 8535/8536/8537)
Power Requirements Backplane powered via Yokogawa I/O base; no external PSU connection to the module
Communication Interfaces Internal FIO backplane for controller/remote node communication; field wiring via terminal board
Installation Method Plug-in card for Yokogawa FIO base/rack; front insertion and replacement

If you’re matching into an existing I/O island, it’s smart to confirm the module’s full code (ADV551-P50D5A00) against your current installed base and node firmware. That small step usually avoids cross-revision surprises.

Application Fields

ADV‑series modules like this are widely used in:

  • Oil & Gas and Petrochemicals – brownfield DCS expansions and spare-part strategies for process units
  • Chemicals and Specialty Materials – standardized I/O cards for utility and batch skids
  • Power & Utilities – control-room cabinets where lifecycle continuity is valued
  • Water & Wastewater – steady-state operation with straightforward maintenance
  • Pulp & Paper / Food & Beverage – steady expansions without controller migrations

Advantages & Value

  • Reliability – Yokogawa I/O modules are known for long service life and low nuisance faults in control-room environments.
  • Compatibility – ADV551-P50D5A00 aligns with existing Yokogawa FIO practices, reducing engineering rework during replacements.
  • Cost control – Keeping the same module family usually avoids marshalling changes and saves commissioning time.
  • Technical support – Documentation and field experience are mature; most technicians recognize the handling and LED patterns right away.

Installation & Maintenance

  • Cabinet conditions – Install in a clean, dry control cabinet with adequate ventilation. Maintain clearance for airflow and service access.
  • Wiring practice – Field wires terminate on the designated Yokogawa terminal board. Keep signal and power separated; follow shield grounding rules.
  • Module handling – Observe ESD precautions; power down or follow Yokogawa’s recommended replacement procedure per your system redundancy.
  • Routine checks – Visually inspect terminal tightness, look for discoloration, and review diagnostic LEDs during scheduled maintenance.
  • Documentation – Match the full code (P50D5A00) in your spares list so maintenance teams pick a like-for-like unit.

Quality & Certifications

  • Meets mainstream industrial approvals for control-room I/O (such as CE); UL/CSA marking is commonly available on Yokogawa I/O families.
  • RoHS-aligned builds are typical for current-production modules.
  • Manufacturer’s warranty: commonly 12 months on Yokogawa hardware; our supply warranty is 365 days.

Common Supporting Components (for Planning)

For cabinet planning, plants often pair ADV-series modules with Yokogawa remote I/O node/base units and the matching terminal boards. In many cases you’ll see:

  • Remote I/O base/node – The backplane that powers and communicates with the module.
  • Terminal board – The field wiring interface kept in place during module replacement to speed up turnaround.
  • Interconnecting cable sets – Factory cables between the terminal board and the base where applicable.

One thing I appreciate is how these pieces let you expand channel count without reworking the marshalling area, provided the cabinet has spare slots and power budget.

Customer note: “Swapping an ADV-series card with the same revision took under 15 minutes including documentation; no field rewiring needed.”

If you’d like, share a photo of your I/O cabinet label or a BOM extract and I’ll double-check the revision match before you place the order.

Reviews

There are no reviews yet.

Be the first to review “Yokogawa ADV551-P50D5A00 – Field I/O Module for CENTUM VP/CS Series Remote I/O”

Your email address will not be published. Required fields are marked *

zzfyplc_Lily

Related products