Description
Watlow DC10-12P0-0000 – DIN-A-MITE C Solid-State Power Controller for Single‑Phase Heater Loads
The Watlow DC10-12P0-0000 sits in the DIN-A-MITE C family, a compact SCR-based power controller that’s typically used to drive single-phase resistive heaters with tight, repeatable control. From my experience, this series is a dependable alternative to mechanical contactors—no arcing, no coil chatter, and far less maintenance in multi-zone applications. You might notice that it drops right into existing heater circuits and pairs neatly with temperature controllers for phase-angle or burst-fire control, depending on the submodel.
Company’s Order Placement Process and Guarantees
- Warranty: 365 days
- Delivery: 1 week for in-stock items; no more than one month at the latest
- Payment: 50% advance payment; full payment prior to delivery
- Express options: FedEx, UPS, DHL
Key Features
- Solid-state reliability – SCR output eliminates mechanical wear, typically boosting uptime in heater circuits.
- Compact DIN-rail form factor – Saves panel space and makes retrofits faster in crowded cabinets.
- Analog control capability – Accepts common process control signals in many cases (e.g., 4–20 mA, 0–10 Vdc, or potentiometer), enabling smooth power modulation.
- Load voltage in the 120/240 VAC class – The DC10-12P0-0000 variant typically targets single-phase 120/240 VAC heater loads at 50/60 Hz.
- Built for industrial panels – LED status indication, finger-safe terminals on most builds, and straightforward wiring for maintenance teams.
- Thermal management options – Designed to work with appropriate heat sinking and semiconductor fusing for higher current applications.
Technical Specifications
| Brand / Model | Watlow DC10-12P0-0000 (DIN-A-MITE C series) |
| HS Code | 8536.49 (solid-state/other relays, >60 V, typical classification) |
| Power Requirements | Load supply typically 120/240 VAC, 50/60 Hz; control input analog (model dependent) |
| Operating Temperature | 0 to 50 °C ambient (typical for cabinet-mounted SSR controllers) |
| Signal Input / Output Types | Input: analog process signal (commonly 4–20 mA, 0–10 Vdc, or potentiometer); Output: single-phase SCR to heater load |
| Communication Interfaces | None (discrete/analog control; no fieldbus) |
| Installation Method | DIN-rail (35 mm) or panel mount with screws; vertical orientation recommended for cooling |
| Dimensions & Weight | Compact DIN-rail footprint; height ~110 mm; width ~60–80 mm; weight typically < 1 kg |
Note: The DC-series numbering suggests this submodel is a single-phase DIN-A-MITE C with analog/phase-control capability in the 120/240 VAC class. If you need exact current rating and input type for “12P0,” we can confirm against your heater load and control signal before shipment.
Application Fields
- Plastic extrusion and thermoforming heater zones
- Industrial ovens, kilns, curing lines, and environmental chambers
- Food/packaging seal bars and shrink tunnels
- Heat tracing and warming equipment
- Semiconductor and lab tools where stable heat input is needed
Advantages & Value
- Reduced maintenance cost – No contacts to pit or replace; in many cases, service intervals lengthen significantly versus contactors.
- Better temperature stability – Smooth power modulation typically improves process consistency and reduces overshoot.
- Easy retrofit – DIN-rail mounting, straightforward wiring, and compatibility with common loop/voltage signals make upgrades quick.
- Compatible ecosystem – Plays well with Watlow temperature controllers (e.g., PM PLUS, EZ-ZONE), standard fusing, and panel hardware.
- Procurement-friendly – Short lead times on standard builds and global approvals streamline project schedules.
One thing I appreciate is how forgiving the DIN-A-MITE C is in real plants. A customer in a plastics facility told us their team swapped three contactor banks for DC-series units and immediately cut nuisance downtime—just fewer moving parts to fail.
Installation & Maintenance
- Panel environment – Mount vertically on a 35 mm DIN rail inside a ventilated cabinet; allow clearance above/below for airflow and any heat sink used.
- Wiring – Use appropriately sized copper conductors; torque terminals per datasheet; earth ground the chassis; route signal leads away from high-current load cables.
- Protection – Fit semiconductor fuses or UL-class fuses rated for SCR protection; add MOV/RC snubbers for inductive loads if present.
- Tuning & control – Match the control input type (current, voltage, or pot) with your temperature controller; for phase-angle, verify plant harmonics policy.
- Routine checks – Quarterly dust cleaning, terminal re-torque, and visual LED/status check; verify heat sink remains below rated temperature under worst-case load.
Quality & Certifications
- CE compliant
- UL/cUL recognition on most DIN-A-MITE C configurations
- RoHS-conforming design in typical current builds
- Manufacturer’s warranty: 12 months
Helpful Accessories & Compatible Items
- Temperature controllers: Watlow PM PLUS or EZ-ZONE (4–20 mA / 0–10 V outputs)
- Semiconductor fuses and DIN holders sized to heater current (e.g., fast-acting aR type)
- DIN-rail heat sinks and thermal pads where higher load currents are expected
- Panel accessories: line filters, MOV surge protection, and main disconnects
If you can share the heater kW, supply voltage, and control signal (for example 4–20 mA or 0–10 Vdc), we’ll verify the exact DC10-12P0-0000 submodel fit and set the delivery window accordingly.







Reviews
There are no reviews yet.