Description
GE PACSystems RX3i IC695ALG626 – Analog Input Module for Precise Industrial Signal Acquisition
The IC695ALG626 sits in the GE PACSystems RX3i rack and, in most cases, serves as a multi‑channel analog input module for voltage and 4–20 mA current signals. From my experience with RX3i installations, this model is chosen when teams want stable, noise‑resistant measurements and straightforward integration with existing RX3i CPUs and networks. You might notice that it simplifies panel wiring and channel configuration, which typically speeds up commissioning on process lines, test stands, and machine tools.
Company’s Order Placement Process and Guarantees
- Quotation & confirmation: We confirm stock and pricing, then send a pro-forma for your approval.
- Payment terms: 50% advance payment; full payment prior to delivery.
- Lead time: 1 week if in stock; no more than one month at the latest.
- Logistics: Express delivery via FedEx, UPS, or DHL—tracking shared immediately after dispatch.
- Warranty: 365 days warranty; genuine, fully tested hardware before shipment.
Key Features
- Designed for RX3i backplane – Seamlessly integrates with IC695 CPUs and network modules through the RX3i rack, so no extra interface cards are needed.
- Multi‑channel analog input – Typically supports multiple voltage and 4–20 mA channels, helping reduce rack footprint in dense I/O panels.
- Configurable ranges – It appears that standard ranges like 0–10 V, ±10 V, and 0/4–20 mA can be selected per channel for mixed‑signal applications.
- Industrial‑grade filtering – From my experience, RX3i analog modules offer digital filtering that smooths noisy signals in high‑EMI environments.
- Diagnostics – Channel status and fault flags typically help maintenance teams spot wiring errors or sensor issues quickly.
- Field‑friendly wiring – Removable terminal block makes swaps easier during downtime; labeling stays clean and serviceable.
- Serviceability – In many cases, RX3i I/O supports online replacement when the CPU and application allow, minimizing system interruption.
Customer feedback: “We swapped in the IC695ALG626 on a batch line and saw smoother 4–20 mA trends without touching the PLC logic—just range configuration and filtering. Startup was quicker than expected.”
Technical Specifications
| Brand / Model | GE PACSystems RX3i / IC695ALG626 |
| HS Code | 8538.90 (Parts for industrial control equipment) |
| Power Requirements | Backplane powered via RX3i rack (5 VDC supplied by RX3i power supply; consumption varies by configuration) |
| Signal Input Types | Analog inputs; typically configurable for common voltage (e.g., 0–10 V, ±10 V) and current (0/4–20 mA) ranges |
| Resolution | High‑resolution A/D (commonly 15–16 bit in RX3i analog modules) |
| Communication Interface | RX3i backplane interface; configured in PACSystems software environment |
| Installation Method | Single‑slot module for IC695CHSxxx RX3i racks; field wiring via removable terminal block |
| Operating Temperature | Typically 0 to 60 °C; 5–95% RH non‑condensing |
| Dimensions & Weight | Standard RX3i single‑slot form factor (fits all IC695CHS racks) |
| Certifications | CE, UL/cUL, RoHS (typical for PACSystems RX3i modules) |
Related or Supporting Products
- IC695CHS012 / IC695CHS016 / IC695CHS007 – RX3i rack chassis (12/16/7‑slot). Choose based on I/O count and panel space.
- IC695PSA040 / IC695PSD040 – RX3i power supplies (AC or DC). Sized to your backplane load.
- IC695CPU310 / IC695CPU320 – RX3i CPUs with ample memory and logic scan performance for mixed analog/digital systems.
- IC695ETM001 – RX3i Ethernet module for plant network integration and remote diagnostics.
- IC695ALG616 – RX3i analog input module with higher channel density in many cases; useful when you need more AI points per slot.
- IC695ALG708 – RX3i analog output module; pair with the IC695ALG626 when closed‑loop control requires analog actuation.
Installation & Maintenance
- Panel & cabinet: Mount the IC695CHS rack on a grounded backplate with adequate ventilation. Maintain typical 50 mm clearance above/below for airflow.
- Wiring practices: Use shielded twisted pair for analog runs. Land shields at a single ground point to avoid loops; separate analog from high‑voltage and VFD cabling.
- Power budget: Verify the RX3i power supply capacity for the total rack load. Add margin for future expansion.
- Configuration: Set channel ranges and filters in the PACSystems programming environment. Validate scaling with a known reference signal.
- Safety: De‑energize field loops before servicing. If performing online replacement, follow GE RX3i procedures and confirm the controller mode supports it.
- Routine maintenance: Periodically retorque terminals, clean dust with dry air, and review diagnostics. Annual verification of analog scaling and, if needed, recalibration is recommended.
- Firmware/software: Keep the PACSystems programming tools and CPU firmware aligned. In many cases, updated tools improve diagnostics and stability.
Quality & Certifications
- Certifications: CE, UL/cUL, and RoHS compliance are typical across the PACSystems RX3i range for global deployment.
- Warranty: 365 days from delivery; replacement or repair support during the warranty period.
- Traceability: Each unit is inspected and function‑tested; serial and revision details recorded before shipment.
If you’re matching the IC695ALG626 to an existing RX3i project file, send the part revision and rack layout. We’ll double‑check compatibility and power budget so you don’t run into surprises during commissioning.






Reviews