ProSoft ILX34-AENWG2 – Wireless POINT I/O adapter for EtherNet/IP islands

1 Brand: ProSoft
2 Model: LX34-AENWG2
3 Quality: Original module
4 Warranty: 1 year
5 Delivery time: 1 week in stock
6 Condition: New/Used
7 Shipping method: DHL/UPS

Categories: Tags:
contact qrcode

Need help?
Email: sales@fyplc.cn
Tel/WhatsApp: +86 173 5088 0093

Description

ProSoft ILX34-AENWG2 – Wireless POINT I/O adapter for EtherNet/IP islandsILX34-AENWG2IK340

The ProSoft ILX34-AENWG2 is designed to bring wireless flexibility to Rockwell 1734 POINT I/O systems. From my experience, it’s typically used when you need to mount I/O on moving equipment, mobile carts, or hard‑to‑reach areas and still exchange cyclic EtherNet/IP data with a CompactLogix or ControlLogix controller. You might notice that it keeps the familiar POINT I/O form factor, so it drops into standard terminal bases and DIN‑rail enclosures without drama.

One thing I appreciate is how it behaves like a transparent EtherNet/IP bridge while riding a robust industrial Wi‑Fi link (802.11 a/b/g/n in most cases). In many projects this removes slip rings or festoon cabling, and it seems to pay off quickly in reduced maintenance. A packaging OEM told us they typically cut install time on rotating turrets by half using ILX34 wireless POINT I/O.

Order Placement Process and Guarantees

  • Warranty: 365 days
  • Lead time: 1 week when in stock; no more than one month at the latest
  • Payment: 50% advance payment; full payment prior to delivery
  • Express options: FedEx, UPS, DHL

Key Features

  • Wireless POINT I/O integration – Enables EtherNet/IP I/O over industrial Wi‑Fi for remote or moving I/O nodes.
  • 802.11 a/b/g/n radios – 2.4/5 GHz capability in most deployments; choose channels and security to fit plant standards.
  • EtherNet/IP data exchange – Cyclic I/O data mapped to your controller without adding protocol converters to the PLC program.
  • POINT I/O form factor – Fits 1734 terminal bases on DIN rail, so enclosure design stays compact.
  • Industrial security – WPA2‑PSK/WPA2‑Enterprise support is commonly used; aligns with IT/OT security policies.
  • Diagnostics you can use – Signal quality and link status make commissioning faster and ongoing maintenance predictable.
  • Flexible topologies – Bridge/client modes for machine‑level islands, AGVs, turntables, or tooling carriers.

Technical Specifications

Brand / Model ProSoft ILX34-AENWG2
HS Code 8517.62 (Data communication apparatus for wired/wireless networks)
Power Requirements 24 VDC nominal (typically 18–32 VDC)
Dimensions & Weight POINT I/O slice form factor; single‑width module for 1734 base (compact DIN‑rail footprint)
Operating Temperature Typically 0 to 55 °C (32 to 131 °F) in control cabinets
Signal I/O Types EtherNet/IP cyclic I/O data over wireless; no direct analog/discrete channels on the gateway
Communication Interfaces 1x 10/100Base‑T (RJ45); IEEE 802.11 a/b/g/n (2.4/5 GHz); supports WPA2 security
Protocols EtherNet/IP adapter/bridge; Layer‑2 transparent bridging for I/O traffic
Installation Method DIN rail on 1734 POINT I/O terminal base; external antennas mounted to panel or mast as required

Related or Supporting Products

  • ILX34-MBS232 / ILX34-MBS485 – POINT I/O Modbus Serial modules; pair well when you need serial device data alongside wireless I/O.
  • RLX2-IHNF industrial radios
  • – Higher‑power Wi‑Fi radios used as infrastructure or backhaul where longer ranges or roaming are needed.
  • 1734-AENTR (Allen‑Bradley) – Redundant EtherNet/IP POINT I/O adapter; a wired alternative when wireless isn’t permitted in certain zones.
  • 1734-TB / 1734-TBS terminal bases – Required POINT I/O base accessories for mounting and field wiring.
  • Industrial antennas & RF leads – Low‑loss coax, panel or omni antennas; choose gain/polarization to match site survey results.

Quick field note: a food & bev user replaced festoon cabling on a palletizer with ILX34-AENWG2 and an RLX2 access point; after setting 5 GHz DFS channels and WPA2‑Enterprise, their downtime from cable snags dropped to near zero.

Installation & Maintenance

  • Cabinet & environment – Mount on DIN rail in a ventilated control cabinet meeting industrial standards (typically IP54 or better). Keep RF cables clear of high‑noise conductors.
  • Power & wiring – 24 VDC supply with proper grounding. Use shielded Cat5e/6 for the RJ45 run; separate from VFD and motor power.
  • RF planning – Perform a site survey. Select 5 GHz when possible to reduce interference; set channel width and power to suit distance and multipath.
  • Antenna placement – Maintain line of sight or solid Fresnel clearance. Use industrial antennas with correct gain; secure coax, weather‑proof outdoor connectors.
  • Safety – Lockout power before wiring; follow local RF exposure and ATEX/area rules if applicable.
  • Routine maintenance – Review link RSSI/SNR trends, clean antenna connections annually, and apply firmware updates during planned downtime. Back up radio and PLC configurations.

Quality & Certifications

  • Certifications – CE, FCC, RoHS; UL/cUL for industrial control equipment (certification sets can vary by region and radio variant).
  • Manufacturer’s warranty – ProSoft typically provides a limited 1‑year warranty on hardware.