GE IS200WETBH1ABA – Exciter Terminal Board for EX2100 / Mark VI, dependable field I/O termination and conditioning

1 Brand: GE
2 Model: IS200WETBH1ABA
3 Quality: Original module
4 Warranty: 1 year
5 Delivery time: 1 week in stock
6 Condition: New/Used
7 Shipping method: DHL/UPS

Categories: Tags:
contact qrcode

Need help?
Email: sales@fyplc.cn
Tel/WhatsApp: +86 173 5088 0093

Description

GE IS200WETBH1ABA – Exciter Terminal Board for EX2100 / Mark VI, dependable field I/O termination and conditioningIS200WETBH1ABA

The GE IS200WETBH1ABA (often referred to as the WETB) is an exciter terminal board designed for GE EX2100 and Mark VI excitation control platforms. It provides clean, organized termination of field wiring and the signal conditioning needed for reliable operation in turbine-generator excitation systems. From my experience, plants like it because it drops in neatly with existing harnesses and doesn’t add complexity—no firmware to load, just robust terminals and filtering that behave predictably shift after shift.

Order Placement Process and Guarantees

  • Warranty: 365 days
  • Lead time: 1 week if in stock; no more than one month at the latest
  • Payment: 50% advance payment; full payment prior to delivery
  • Express delivery: FedEx, UPS, DHL

Key Features

  • Purpose-built for GE EX2100 / Mark VI exciters – Provides the primary terminal interface between cabinet field wiring and the exciter control electronics.
  • Signal conditioning and protection – Input filtering, surge suppression, and sensible grounding paths help reduce noise and nuisance trips in many cases.
  • Clean, serviceable wiring – High‑density terminals with clear labeling; simplifies field install, retrofits, and maintenance rounds.
  • Backplane/ribbon connectivity – Directly mates to the associated control boards, avoiding ad‑hoc adapters or custom looms.
  • Simplex and redundant topologies – Typically used in standard EX2100 builds and can be applied in redundant configurations when the cabinet design calls for it.
  • H1 ABA hardware revision – A later hardware build variant aimed at improved reliability and lifecycle availability without altering system behavior.
  • No external communication ports – Reduces cybersecurity surface and configuration overhead; all interfacing is cabinet-internal.

Technical Specifications

Brand / Model GE IS200WETBH1ABA (WETB)
Product Type Exciter Terminal Board for EX2100 / Mark VI excitation systems
HS Code 8538.90 (Parts for electrical control apparatus)
Power Requirements No separate external supply; typically powered via the associated control rack as applicable
Operating Temperature 0 to 60°C typical (cabinet-conditioned)
Signal Input/Output Types Terminations for exciter-related discrete I/O, analog feedback, and PT/CT sense lines used by the excitation control
Communication Interfaces Internal ribbon/backplane connectors; no external serial/Ethernet
Installation Method Mounted within the EX2100/Mark VI cabinet; field wiring via terminal blocks; ESD-safe handling required
Dimensions & Weight Board-level module, standard GE IS200 footprint (typical); consult outline drawing for precise values

Related or Supporting Products

  • IS200EDEXG1A – Excitation feedback/control board; pairs with terminal boards like WETB to process field current/voltage signals.
  • IS200EMIO – Main I/O module used in EX2100; handles A/D conversion and interfaces back to the controller.
  • IS200ECTBG1A – Exciter Contact Terminal Board; focused on discrete I/O terminations, sometimes used alongside or in place of certain WETB I/O depending on cabinet design.
  • IS200WETBH1A / later WETB revisions – Mounting-compatible hardware updates with incremental BOM and layout improvements.

One thing I appreciate is how interchangeable the IS200 boards tend to be across cabinet variants. You might notice minor harness or terminal labeling differences between units, but wiring practices are largely consistent, which keeps outages tight.

Installation & Maintenance

  • Environment & cabinet: Install in a clean, dry, ventilated control cabinet. Maintain ambient within 0–60°C typical and avoid direct dust/oil exposure.
  • Wiring: Use shielded cable for analog and PT/CT circuits; land shields per cabinet grounding practice. Torque terminals per GE guidance; avoid over‑tightening.
  • Grounding: Keep low‑level signal returns separate from power grounds to minimize noise; follow the EX2100 earthing scheme.
  • Handling: Observe ESD precautions. De‑energize the cabinet before install/replace; verify isolation on PT/CT circuits.
  • Routine checks: During scheduled outages, re‑seat connectors, inspect terminals for looseness, and check for discoloration or corrosion.
  • Calibration/firmware: No board‑level firmware or calibration on the WETB; functional checks are typically loop‑back or end‑to‑end I/O validation.
  • Spares: Keep at least one tested spare on site; in many cases this prevents extended downtime when a terminal section is damaged by a field surge.

A maintenance lead at a combined‑cycle plant told us a WETB swap and point‑to‑point check took less than an hour because the labeling matched their prints—little things, but they matter on a Sunday night start.

Quality & Certifications

  • Manufacturer standards: Produced within GE’s ISO 9001–aligned quality system.
  • CE/UL: Applied at the exciter system level (EX2100/Mark VI). The WETB is an OEM spare part used within certified systems.
  • RoHS: Legacy OEM spare; exemptions may apply for industrial MRO parts.
  • Warranty: 365 days from shipment (exchange or repair per standard terms).

If you’re refreshing an EX2100 bay or building a strategic spare kit, the IS200WETBH1ABA is a sensible pick—stable revision, straightforward wiring, and typically a direct fit with existing harnessing. If you need help matching revisions or checking cabinet compatibility, share a photo of the card cage and terminal layout and we can confirm before you place the order.

Reviews

There are no reviews yet.

Be the first to review “GE IS200WETBH1ABA – Exciter Terminal Board for EX2100 / Mark VI, dependable field I/O termination and conditioning”

Your email address will not be published. Required fields are marked *

zzfyplc_Lily

Related products