ProSoft MVI69-DFNT – EtherNet/IP (DF1/PCCC over Ethernet) Communication Module for 1769 CompactLogixMVI69-DFNT

The ProSoft Technology MVI69-DFNT drops into a 1769 CompactLogix I/O rack and gives your controller a native way to exchange data with Allen‑Bradley devices speaking DF1/PCCC over Ethernet (often called “DFNT”). From my experience, it’s a clean option when you need your CompactLogix to poll SLC™ 5/05, PLC‑5® Ethernet, older PanelView® terminals, or MicroLogix™ with Ethernet—without juggling separate gateways. You might notice that it behaves like a dedicated EtherNet/IP Client/Server engine living in the 1769 slot, mapping data straight into controller tags through the supplied Add‑On Instruction.

Our Order Placement Process and Guarantees

  • Warranty period: 365 days
  • Lead time: 1 week if in stock; no more than 1 month at the latest
  • Payment: 50% advance payment; full payment prior to delivery
  • Express delivery: FedEx, UPS, DHL

Key Features

  • 1769 CompactLogix integration – Installs as a standard 1769 single‑slot module; data appears in controller tags via the included AOI, which keeps the ladder logic simple.
  • EtherNet/IP Client/Server (DFNT) – Communicates using DF1/PCCC encapsulation over Ethernet for SLC 5/05, PLC‑5 Ethernet, Ethernet‑based PanelView, and many MicroLogix models.
  • 10/100Base‑TX Ethernet – Standard RJ45 copper port for quick hookup to plant networks; typically works well with managed or unmanaged switches.
  • Deterministic data mapping – From my experience, the module’s internal database maps cleanly to Logix tags, so HMI/PLC data exchange stays consistent during runtime.
  • ProSoft Configuration Builder (PCB) – PC‑based configuration utility; you can define devices, transactions, and diagnostics in minutes.
  • Industrial operating range – Designed for control cabinets; in many cases it runs reliably across typical plant floor temperatures.
  • Diagnostics that help – You might notice the status and comms counters make troubleshooting straightforward when you’re bringing a legacy cell back online.

Typical Use Cases

  • Link a CompactLogix line controller to an SLC 5/05 utilities PLC to exchange status words and recipe data over Ethernet.
  • Read/write integer files in a PLC‑5 controlling a batching skid while modernizing the main DCS to CompactLogix.
  • Serve tag data to an older PanelView Standard Ethernet HMI without rewriting the whole HMI project.

“We replaced two standalone gateways with a single MVI69‑DFNT in the 1769 rack. Commissioning took one afternoon and the legacy PLC‑5 data was mapped right into Logix tags. Maintenance has been simpler since.” — Packaging OEM, North America

Technical Specifications

Brand / Model ProSoft Technology MVI69-DFNT
HS Code 8537.10 (Boards, panels and other bases, for a voltage ≤ 1000 V)
Platform Compatibility Rockwell Automation 1769 CompactLogix / Compact GuardLogix systems
Power Requirements Backplane‑powered via 1769 bus (5 VDC); no external supply required
Operating Temperature 0 to 60 °C (32 to 140 °F) typical industrial rating
Signal I/O Types 10/100Base‑TX Ethernet data; backplane data exchange to controller tags
Communication Interfaces 1 × RJ45 (10/100 Mbps Ethernet); 1769 backplane interface
Supported Protocols EtherNet/IP explicit messaging with DF1/PCCC encapsulation (“DFNT”)
Dimensions & Weight Standard 1769 single‑slot Compact I/O form factor
Installation Method Mounts in a 1769 I/O bank with power supply and end cap; DIN‑rail or panel via the 1769 assembly

Related or Supporting Products

  • MVI69-MNET – For Modbus TCP communications from CompactLogix; choose this when you’re targeting drives, power meters, or PLCs using Modbus TCP.
  • MVI69-MCM – Serial Modbus (RTU/ASCII) Master/Slave; typically used for legacy serial instruments and weigh scales.
  • MVI56E-DFNT – ControlLogix version of the DFNT module; same concept for 1756 platforms if you’re standardizing across chassis sizes.
  • PLX51-DF1-ENI – Compact gateway for DF1 Serial to EtherNet/IP; a good fit when you need DF1 serial rather than DF1/PCCC over Ethernet.
  • 1769-PA/PD Power Supply & 1769 End Cap – Required hardware for any 1769 I/O bank hosting the MVI69‑DFNT.
  • Industrial Ethernet accessories – Shielded RJ45 patch cables, DIN‑rail switches (managed with IGMP snooping recommended on larger EtherNet/IP networks).

Installation & Maintenance

  • Cabinet & mounting – Install in a clean, dry enclosure. Follow 1769 spacing and grounding practices. Keep low‑voltage signal wiring away from high‑noise conductors.
  • Ventilation – Provide adequate airflow; from my experience, modules run cooler with a small panel fan when ambient approaches 50–60 °C.
  • Networking – Use shielded Cat5e/6 cables. Managed switches with storm control and IGMP snooping typically improve EtherNet/IP performance on busy plants.
  • Wiring & ESD – De‑energize the rack before adding/removing modules. Observe ESD precautions when handling the 1769 assembly and connectors.
  • Configuration – Set up devices and transactions in ProSoft Configuration Builder, then import the AOI and map tags. Test communications with a single peer first before scaling.
  • Routine maintenance – Periodically back up PCB projects and Logix programs, check connector tightness, clean dust with dry air, and apply firmware updates when released.

Quality & Certifications

  • CE and RoHS compliant; UL/cUL listings are commonly available for ProSoft 1769 modules (including use in industrial control panels).
  • Manufacturer warranty: typically 1 year standard from ProSoft Technology.
  • Each unit is functionally tested before shipment in most cases; serialized records aid traceability.

One thing I appreciate is how the MVI69‑DFNT lets you modernize in stages. You can keep that PLC‑5 or SLC online, connect it over Ethernet, and migrate logic module‑by‑module without shutting the cell down.

Reviews

There are no reviews yet.

Be the first to review “ProSoft MVI69-DFNT – EtherNet/IP (DF1/PCCC over Ethernet) Communication Module for 1769 CompactLogix”

Your email address will not be published. Required fields are marked *

zzfyplc_Lily

Related products