ABB NETA-01 Ethernet Adapter – Bring ABB AC drives onto plant Ethernet/Modbus TCPNETA-01

ABB’s NETA-01 is an industrial Ethernet gateway that links ABB AC drives (ACS/ACH/ACS800 families that use DDCS) to your plant network. From my experience, it’s a straightforward way to pull real-time drive data into SCADA or a PLC over standard Ethernet, typically via Modbus/TCP, without touching the motor control wiring. You might notice that commissioning goes quickly—fiber to the drive, 24 VDC power, set an IP address, and you’re online.

Our Order Placement Process and Guarantees

  • Warranty: 365 days
  • Lead time: 1 week if in stock; no more than 1 month at the latest
  • Payment: 50% advance; balance before delivery
  • Shipping: FedEx, UPS, DHL (express)

Key Features

  • Ethernet connectivity for ABB drives – Provides a clean Ethernet bridge to drives using DDCS; ideal for linking ACS/ACH/ACS800 series to control systems.
  • Modbus/TCP support – Typically used to read/write key drive parameters (speed, current, status words) and issue control commands where permitted.
  • Industrial-grade isolation – Fiber optic DDCS side helps isolate electrical noise between the drive and the Ethernet network.
  • Simple installation – DIN-rail mount with clear terminaling; RJ45 on the front, fiber to the drive, and a 24 VDC feed.
  • Diagnostics at a glance – Front-panel LEDs for link/activity and status, so fault chasing stays practical on the plant floor.
  • Fits brownfield upgrades – In many cases, it lets you add Ethernet visibility to existing ABB drive lines without changing the drive control architecture.

Technical Specifications

Brand / Model ABB NETA-01 Ethernet Adapter
HS Code 8517.62 (Data communication apparatus for digital line systems)
Power Requirements 24 VDC (±10%), typical consumption < 5 W; external supply
Communication Interfaces 1 × RJ45 (10/100BASE‑T Ethernet); DDCS fiber optic link to drive
Protocols Modbus/TCP; standard TCP/IP services (static IP or DHCP)
Signal I/O Types Ethernet (RJ45); DDCS (fiber optic); front status LEDs
Operating Temperature 0 to +50 °C (typical for ABB option modules)
Installation Method 35 mm DIN-rail mount in control cabinet; fiber to drive DDCS; 24 VDC terminal
Dimensions & Weight Compact DIN-rail module; approx. 120 × 70 × 55 mm; ~0.25 kg

Where it typically fits

Maintenance teams usually deploy NETA-01 to expose ABB drive parameters to PLCs or SCADA without replacing existing fieldbuses. One customer in a food plant tied an ACS800 mixer line into Modbus/TCP and cut troubleshooting time dramatically—the operators could see drive trips and motor load on the HMI instead of walking to the MCC.

Related or Supporting Products

  • ABB FENA-01 – Ethernet adapter for drives; supports EtherNet/IP and Modbus/TCP on many newer ABB drives (compact, dual-purpose).
  • ABB FENA-11 – PROFINET RT/IRT capable adapter for ABB drives; useful when the plant standard is PROFINET.
  • ABB FPBA-01 – PROFIBUS DP interface option; a good alternative in PROFIBUS-based facilities.
  • ABB RDCO-02 – DDCS communication option for certain ACS800 configurations; used when additional fiber links are needed.

Installation & Maintenance

  • Cabinet environment – Install on 35 mm DIN rail in a clean, dry enclosure. Provide basic ventilation; keep ambient within the stated temperature range.
  • Power & wiring – 24 VDC from a regulated industrial supply. Use shielded Cat5e/6 for Ethernet. Route fiber away from tight bend radii; respect minimum bend radius per fiber type.
  • Grounding – Bond cabinet ground properly; maintain Ethernet shield continuity to reduce EMI in noisy VFD environments.
  • Network setup – Assign static IP or enable DHCP (as allowed on your network). Map Modbus registers to the PLC/SCADA tags you need (speed ref, status, alarms).
  • Safety – De-energize the cabinet before wiring. Observe ESD precautions when handling the module and fiber connectors.
  • Routine maintenance – Periodically inspect connectors, clean dust from vents, verify link/activity LEDs, and back up configuration. Firmware updates can be applied if ABB releases improvements—schedule during planned downtime.

Quality & Certifications

  • Certifications: CE and RoHS compliant; UL/cUL recognition is commonly provided for ABB drive accessories (varies by region).
  • Manufacturer quality: Produced under ABB’s ISO 9001 manufacturing system, which in many cases underpins consistent build quality.
  • Warranty: 365-day warranty from us; ABB’s factory warranty terms may vary by region and application.

Reviews

There are no reviews yet.

Be the first to review “ABB NETA-01 Ethernet Adapter – Bring ABB AC drives onto plant Ethernet/Modbus TCP”

Your email address will not be published. Required fields are marked *

zzfyplc_Lily

Related products