Schneider Electric NW-BM85C002 – Modbus Plus Bridge Multiplexer for Serial Modbus Integration

1 Brand: Schneider Electric
2 Model: NW-BM85C002
3 Quality: Original module
4 Warranty: 1 year
5 Delivery time: 1 week in stock
6 Condition: New/Used
7 Shipping method: DHL/UPS

contact qrcode

Need help?
Email: sales@fyplc.cn
Tel/WhatsApp: +86 173 5088 0093

Description

Schneider Electric NW-BM85C002 – Modbus Plus Bridge Multiplexer for Serial Modbus IntegrationNW-BM85C002-1

The NW-BM85C002 is Schneider Electric’s classic BM85 Bridge Multiplexer variant for linking a Modbus Plus backbone to multiple serial Modbus devices. From my experience, this unit is still a practical choice when you need to keep legacy Modicon 984/Quantum systems running while pulling data from drives, power meters, barcode readers, or remote I/O over RS‑232/RS‑485. It streamlines multi-drop serial segments and lets a Modbus Plus PLC poll several serial Modbus lines in parallel, which typically cuts down scan time and cabling headaches.

Company’s Order Placement Process and Guarantees

  • Warranty: 365 days
  • Delivery time: 1 week for in‑stock items; no more than one month at the latest
  • Payment: 50% advance payment, full payment before delivery
  • Express options: FedEx, UPS, DHL

Key Features

  • Modbus Plus to serial bridging – Connects a 1 Mbps Modbus Plus network to multiple serial Modbus lines, ideal for brownfield upgrades.
  • Multi‑port serial aggregation – Typically supports multiple independently configurable serial ports (RS‑232/RS‑485), so you can run several Modbus RTU/ASCII segments in parallel.
  • Deterministic PLC access – Lets a Modicon PLC on Modbus Plus poll downstream serial devices without custom gateway logic.
  • Front‑panel setup – You might notice that most site changes are handled via front‑panel switches and status LEDs, which keeps commissioning straightforward.
  • Rugged for control cabinets – Designed for continuous operation in industrial panels; typically 0…60 °C ambient when properly ventilated.
  • Legacy compatibility – Plays nicely with established Modicon 984/Quantum environments and many installed Modbus devices in the field.

Technical Specifications

Brand / Model Schneider Electric NW-BM85C002 (BM85 Bridge Multiplexer variant)
HS Code 8517.62 (Data communication equipment)
Power Requirements AC mains, 120–240 VAC, 50/60 Hz (typical for this series)
Operating Temperature 0 to 60 °C (with appropriate cabinet ventilation)
Signal Input/Output Types Modbus Plus (1 Mbps) to multiple serial Modbus ports (RS‑232 / RS‑485; RTU/ASCII)
Communication Interfaces 1 x Modbus Plus network port; multiple serial ports configurable per channel
Installation Method Panel/cabinet mounting inside an industrial enclosure

Related or Supporting Products

  • Schneider 416NHM30030 (SA85 PCI) – Modbus Plus PC network adapter for engineering PCs; helpful for network diagnostics and node configuration.
  • Modbus Plus trunk/drop cables and tees – Required for proper MB+ topology and shielding; choose lengths and tees to match your plant’s trunk and drop rules.
  • RS‑485 termination/bias components – Keeps multi‑drop serial segments stable at higher baud rates.
  • Schneider TSXETG100 – In many cases used as an Ethernet‑to‑serial Modbus gateway if you’re modernizing away from Modbus Plus but still need serial Modbus visibility.

Installation & Maintenance

One thing I appreciate is how predictable BM85 deployments are when the basics are done right. A few field‑tested tips:

  • Cabinet & ventilation: Mount in a clean, dry control cabinet. Keep ambient typically within 0–60 °C and allow clearance for airflow. Ground the panel to reduce noise.
  • Wiring practices: Use the correct Modbus Plus shielded cable and follow trunk/drop rules with proper terminations. For RS‑485, use twisted pair, fit termination and bias resistors at segment ends, and keep cable shields bonded at one point to avoid loops.
  • Addressing & parameters: Set the Modbus Plus node address via the front controls. Configure each serial port’s baud rate, parity, and protocol (RTU/ASCII) to match the downstream devices.
  • Safety: De‑energize before wiring, segregate low‑level comms from power cabling, and verify earth continuity. In most cases, surge protection on field lines extends service life.
  • Routine maintenance: Periodically inspect connectors, check LED diagnostics, and clean dust from the enclosure. Firmware changes are uncommon on legacy units; if present, follow Schneider’s guidance and keep a spare configured unit on the shelf.

Quality & Certifications

  • Manufacturer quality: Schneider Electric industrial grade manufacturing
  • Certifications: Typically CE and UL/CSA for industrial control equipment; RoHS compliance may vary by production lot and region
  • Warranty: 365 days from shipment

A quick note from the field: plants often keep one NW-BM85C002 in reserve because serial fleets can be diverse, and having a pre‑configured spare minimizes downtime. If you share your current Modbus device list and baud settings, we can typically pre‑check compatibility and suggest a clean port mapping that avoids polling collisions.

Reviews

There are no reviews yet.

Be the first to review “Schneider Electric NW-BM85C002 – Modbus Plus Bridge Multiplexer for Serial Modbus Integration”

Your email address will not be published. Required fields are marked *

zzfyplc_Lily

Related products