FOXBORO P0904HN-LZS-1500-3FOX – Pre-terminated Interconnect Cable for I/A Series FBM-to-TA Wiring

1 Brand: FOXBORO
2 Model: P0904HN-LZS-1500-3FOX
3 Quality: Original module
4 Warranty: 1 year
5 Delivery time: 1 week in stock
6 Condition: New/Used
7 Shipping method: DHL/UPS

contact qrcode

Need help?
Email: sales@fyplc.cn
Tel/WhatsApp: +86 173 5088 0093

Description

FOXBORO P0904HN-LZS-1500-3FOX – Pre-terminated Interconnect Cable for I/A Series FBM-to-TA WiringP0904HN-LZS-1500-3FOXP0904HN-LZS-1500-3FOX-2

The FOXBORO P0904HN-LZS-1500-3FOX is a factory-terminated interconnect cable typically used to link I/A Series FBM modules to their Termination Assemblies (TAs) in control cabinets. From my experience, this is the sort of harness plants choose when they want repeatable, low-error wiring in brownfield upgrades or fast commissioning jobs. The “LZS-1500” designation points to a ~1.5 m length, which seems to be the sweet spot for panel-to-marshaling runs without messy slack.

You might notice that pre-terminated FOXBORO assemblies like this reduce panel time dramatically: no hand-crimping in a tight cabinet, fewer landing mistakes, and consistent shielding practices. One thing I appreciate is how these assemblies fit neatly into standard routing paths, so techs can focus on loop checks instead of rework.

Order Placement Process and Guarantees

  • Warranty: 365 days replacement coverage
  • Delivery: 1 week if in stock; no more than one month at the latest
  • Payment: 50% advance payment; full payment prior to delivery
  • Express options: FedEx, UPS, DHL

Key Features

  • Pre-terminated connectors – Reduces wiring errors and speeds up cabinet integration in most cases.
  • Approx. 1.5 m length (LZS-1500) – Practical reach for FBM-to-TA runs without excess coil or tension.
  • Shielding optimized for control signals – Helps maintain signal integrity for analog/digital I/O in electrical noise environments.
  • Cabinet-friendly jacket – Typically rated for industrial control panels; easy to route and tie down.
  • Consistent pinout per FOXBORO standard – Keeps loop identification and maintenance straightforward.
  • Drop-in replacement behavior – Designed for FOXBORO I/A Series FBM-to-TA interfaces, minimizing site modifications.

Technical Specifications

Brand / Model FOXBORO P0904HN-LZS-1500-3FOX
Product Type Pre-terminated interconnect cable (FBM to Termination Assembly)
HS Code 8544.42 (insulated electric conductors, fitted with connectors)
Power Requirements N/A (passive cable assembly)
Length / Dimensions & Weight Approx. 1.5 m length; cabinet-grade OD; ~0.3–0.4 kg typical
Operating Temperature -20 to +60 °C typical for control cabinet environments
Signal I/O Types Low-voltage control signals (discrete and analog) between FBM and TA
Interfaces / Connectors Factory-terminated, keyed multipin connections for FOXBORO I/A Series FBM/TA
Installation Method Panel/cabinet routing; plug-in to FBM and TA; secure and strain-relieve per cabinet standards

Related or Supporting Products

  • FOXBORO FBM200-series modules (e.g., FBM201/FBM211/FBM241) – typical I/A Series I/O modules this cable connects to.
  • FOXBORO Termination Assemblies (TA), P0926-series – cabinet-mounted TAs that receive the FBM signals.
  • FOXBORO baseplates/backplanes, P0916-series – mechanical and electrical mounting for FBMs.
  • Length variants in the same family (subject to availability), such as LZS-0500 (~0.5 m) or LZS-3000 (~3 m), when a shorter or longer run is needed.

A customer in a coker unit retrofit told me the 1.5 m version “hit the sweet spot” for routing across adjacent DIN-rail columns—no need to re-tray or add zip-tie anchors, which saved a few hours per panel during FAT.

Installation & Maintenance

  • Cabinet environment – Keep within standard control cabinet conditions (dry, clean air, -20 to +60 °C typical). Provide adequate ventilation and avoid routing near high-heat sources.
  • Wiring practices – Separate from high-voltage and VFD motor leads to reduce EMI. Maintain bend radius (often ≥ 8× cable OD) and secure with non-abrasive ties.
  • Grounding/shielding – Terminate shields as per FOXBORO or site standard. In many cases, shield is bonded at the TA side only.
  • Connector handling – Seat fully and, where provided, tighten latches/screws to manufacturer torque. Do not pull the cable by the connector body during routing.
  • Routine checks – Periodic visual inspection for abrasion or crushed sections; verify strain relief; perform continuity checks during outages. Light, lint-free cleaning of connector contacts if needed.
  • Change control – Label both ends and record loop mapping; it typically prevents mix-ups during hot cutovers or turnaround work.

Quality & Certifications

  • CE conformity for low-voltage/control environments (typical for this category)
  • RoHS-compliant materials in many cases
  • UL/CSA wiring styles may apply depending on batch and jacket type (check label/spec sheet for exact markings)
  • Manufacturer warranty is typically 12 months; units supplied are covered by our 365-day warranty terms above

Note: Compatibility can vary by FBM/TA variant and site standards. If you share your exact FBM type and TA part number, I can confirm pinout and length fit before you commit.