Description
ABB PM564-RP-ETH – Compact AC500-eCo CPU with Integrated Ethernet for Machine and Process Control
The ABB PM564-RP-ETH is a practical choice when you want a compact PLC CPU with built‑in Ethernet and relay outputs. It sits in the AC500‑eCo family, so you get straightforward engineering with ABB Automation Builder (CoDeSys‑based) and a form factor that fits tight panels. From my experience, this model suits small to mid‑size machines—packaging stations, HVAC skids, material handling cells, and dosing/mixing units—where you need reliable digital I/O, simple networking, and predictable cycle times without overcomplicating the cabinet.
One thing I appreciate is the -RP variant’s relay outputs, which typically let you drive actuators directly in many cases, reducing the need for extra interposing relays. You might notice that the -ETH suffix gives you a standard RJ45 port for programming and SCADA/HMI integration over Ethernet—helpful for OEMs standardizing on Modbus TCP or basic IP networking.
Order Placement Process and Guarantees
- Warranty: 365 days
- Delivery: 1 week if in stock; no more than one month at the latest
- Payment: 50% advance payment; full payment before delivery
- Express options: FedEx, UPS, DHL
Key Features
- Integrated Ethernet (RJ45): Typically 10/100Base‑T for programming, HMI/SCADA connectivity, and Modbus TCP in many cases.
- Onboard digital I/O with relay outputs (RP): Suits direct switching of typical loads without additional interposing relays.
- 24 VDC supply: Common industrial power standard makes cabinet design straightforward.
- Serial communication port: In most deployments, supports Modbus RTU/ASCII via RS‑485/RS‑232 (model dependent).
- CoDeSys‑based engineering: Program with ABB Automation Builder using IEC 61131‑3 languages—helps shorten commissioning time.
- Compact DIN-rail housing: Fits typical control cabinets; neat for multi‑axis stations or skid‑mounted equipment.
- Scalable with ABB I/O: Expand digital/analog I/O using compatible modules as your machine grows.
Technical Specifications
| Brand / Model | ABB PM564-RP-ETH (AC500‑eCo CPU) |
| HS Code | 8537.10 (Programmable controllers and control panels) |
| Power Requirements | 24 VDC nominal (typical) |
| Operating Temperature | 0 to +55 °C (typical for AC500‑eCo CPUs) |
| Signal I/O Types | 24 VDC digital inputs; relay‑type digital outputs (RP variant); analog expansion available via compatible modules |
| Communication Interfaces | 1× Ethernet RJ45 (10/100Base‑T); 1× serial COM (RS‑485/RS‑232, model dependent); programming over Ethernet |
| Installation Method | DIN‑rail mounting (EN 60715); cabinet IP20 environment with proper ventilation |
| Dimensions & Weight | Compact AC500‑eCo CPU housing; slim DIN width suitable for space‑constrained panels |
Related or Supporting Products
- ABB PM554-RP-ETH: Similar CPU with a lighter onboard I/O footprint; good for cost‑sensitive machines.
- ABB PM564-T-ETH: Transistor output version of the same class; better for higher switching frequency than relay outputs.
- ABB PM574-ETH: Higher‑performance CPU if you need more memory or faster logic execution.
- ABB S500 I/O modules (e.g., DI524, DO524, AI523, AO523): Expand digital and analog channels as the system scales.
- ABB CP‑E 24 VDC power supplies: Reliable 24 VDC sources sized for CPU plus field I/O loads.
- ABB CP series HMIs (e.g., CP635): For local operator interface over Ethernet or serial links.
Installation & Maintenance
- Panel environment: Install on EN 60715 DIN rail in an IP20 cabinet; allow top/bottom clearance for airflow. Avoid heat sources and excessive vibration.
- Power & grounding: Use a clean 24 VDC supply with proper over‑current protection; bond the PLC 0V to panel ground as per ABB guidelines.
- Wiring: Separate signal and power cabling; keep Ethernet and serial lines away from high‑frequency drives. Use ferrules and labeled terminals for serviceability.
- Networking: For Modbus TCP, assign a fixed IP and document addressing in the project files. Shielded CAT5e/CAT6 is recommended in noisy environments.
- Routine care: Periodically clean ventilation slots, check terminal tightness, and back up the project to Automation Builder. Firmware updates can be planned during scheduled downtime.
- Commissioning tip: From my experience, validating relay output contact ratings against field loads prevents nuisance failures and extends life.
Quality & Certifications
- CE compliant; typically cULus listed for industrial control equipment
- RoHS compliant materials
- Manufactured under ISO 9001 quality management
- Warranty: 365 days (exchange/repair terms apply)
If you’re standardizing on AC500‑eCo, the PM564-RP-ETH seems to be a sweet spot—Ethernet on board, relay outputs for direct switching, and simple expansion when needed. If you share the application details (I/O counts, protocols, environment), we can validate the exact hardware revision and I/O mix before shipping.