ABB SD853 (3BSE088188R1) – Specialty Digital Module for S800 I/O applications

1 Brand:ABB
2 Model: SD853 (3BSE088188R1)
3 Quality: Original module
4 Warranty: 1 year
5 Delivery time: 1 week in stock
6 Condition: New/Used
7 Shipping method: DHL/UPS

Categories: Tags:
contact qrcode

Need help?
Email: sales@fyplc.cn
Tel/WhatsApp: +86 173 5088 0093

Description

ABB SD853 (3BSE088188R1) – Specialty Digital Module for S800 I/O applicationsSD853-3BSE088188R1

The ABB SD853, part number 3BSE088188R1, sits in ABB’s S800 I/O family and is typically used where you need specialty digital functions on a compact, DIN‑rail mounted I/O segment. From my experience, SD‑series modules are picked when a standard DI/DO won’t cut it—think high‑speed counting, sequence-of-events capture, or other time‑critical digital tasks tied into an AC 800M or Advant-based system via S800 I/O. You might notice that it drops straight onto a TU8xx terminal base, so you keep wiring simple and the footprint tight.

Company’s Order Placement Process and Guarantees

  • Warranty: 365 days
  • Lead time: 1 week when in stock; no more than 1 month at the latest
  • Payment: 50% advance payment; full payment before delivery
  • Express options: FedEx, UPS, DHL

Key Features

  • S800 I/O form factor – Plugs onto TU8xx terminal bases, which keeps installation consistent across your cabinets.
  • Specialty digital functionality – Commonly used for fast digital inputs, counting, or SOE-type applications where timing matters.
  • ModuleBus powered – Draws power via the S800 backplane; no need for separate local power in most cases.
  • Controller-agnostic via S800 – Interfaces upstream through standard S800 I/O infrastructure to AC 800M/Advant systems.
  • Compact and serviceable – Front access for module replacement and labeling; minimizes downtime if a swap is needed.

Technical Specifications

Brand / Model ABB SD853 (3BSE088188R1)
Product Family S800 I/O – Specialty Digital Module
HS Code 8538.90 (Parts suitable for electrical control panels / PLC I/O)
Power Requirements Powered via S800 ModuleBus through TU8xx terminal base (24 VDC nominal supply on the backplane)
Dimensions & Weight Compact S800 I/O module footprint; mounts vertically on DIN‑rail via TU8xx base
Operating Temperature Typically 0 to +55°C for S800 I/O environments (verify per site standards)
Signal I/O Types Specialized digital; commonly applied for high‑speed DI/counter or SOE‑related signals on 24 VDC systems
Communication Interfaces S800 ModuleBus to the system via CI8xx interface modules or AC 800M local I/O
Installation Method Plug‑in to TU810/TU812 (and other compatible TU8xx) terminal bases; DIN‑rail mounted

Related or Supporting Products

  • ABB TU810 / TU812 – Terminal bases for S800 I/O; choose based on wiring style and channel density. These are typically the pieces you mount on DIN rail first.
  • ABB SD833 – Another SD‑series specialty digital module, often used for counter/fast DI tasks; a common alternative depending on required input type.
  • ABB SD822 – Specialty digital module variant frequently seen in pulse counting applications; selection depends on the sensor interface.
  • ABB DI810 / DI811 – Standard 24 VDC digital input modules when high‑speed or SOE features aren’t required.
  • ABB CI854A / CI851 – Communication interface modules used to connect S800 I/O segments to the controller (e.g., via PROFIBUS DP or ModuleBus optics), depending on the architecture.

Installation & Maintenance

  • Cabinet & mounting – Install TU8xx terminal bases on a grounded DIN rail within an enclosure that meets at least IP20. Keep adequate clearance above/below modules for airflow.
  • Power & grounding – Use a clean 24 VDC supply for the S800 backplane. From my experience, a solid protective earth and shield termination point reduces nuisance counts on fast inputs.
  • Wiring – Route field digital lines separately from high‑power cables. You might notice the SD‑series performs best when shielded pairs are grounded at one end only.
  • Environmental – Operate within typical S800 I/O limits (temperature/humidity). Avoid condensation; add cabinet ventilation if ambient exceeds mid‑40s °C.
  • Routine checks – Verify terminal tightness quarterly, clean dust with dry air, and review diagnostics in the DCS for channel state or event buffer anomalies.
  • Firmware/config – If the application uses time‑stamped events, sync controller time across the network and keep controller and CI modules on supported firmware.
  • Spares strategy – Keep at least one spare SD‑series module and a TU8xx base gasket; swap time is usually minutes if labeling is in place.

Quality & Certifications

  • Certifications – Typically CE‑marked; RoHS compliant. UL/cUL recognition applies in many cases for S800 I/O modules (varies by exact variant and region).
  • Manufacturing – Produced under ISO 9001 quality systems by ABB.
  • Warranty – 365‑day warranty from us; ABB standard product policies apply where relevant.
From a recent user note: “We dropped SD‑series modules into an existing S800 rack to pick up high‑rate prox sensors on a conveyor. The timing accuracy seemed stable once we tightened shielding and aligned the controller time, and commissioning was faster than we expected.”