Description
ICS TRIPLEX T8314 – Trusted digital input module for safety-critical control
The ICS TRIPLEX Trusted T8314 is a safety-grade digital input module designed for high-integrity process control. From my experience, it’s typically used to bring 24 Vdc field contacts into a Trusted TMR controller with comprehensive diagnostics and robust noise immunity. You might notice that it fits neatly into existing Trusted I/O racks, so migration or expansion tends to be straightforward on brownfield systems.
One thing I appreciate is how the T8314 balances density with reliability—ideal for ESD systems, burner management, and high-demand trip functions where spurious trips are costly. In many cases, users choose it to standardize on a single DI type across multiple cabinets, leveraging the platform’s proven SIL3 pedigree.
Order Placement Process and Guarantees
- Warranty: 365 days
- Delivery: 1 week when in stock; no more than one month at the latest
- Payment: 50% advance payment; full payment before delivery
- Express options: FedEx, UPS, DHL
Key Features
- Safety-rated digital inputs – Designed for use within the Trusted TMR system in SIL3 applications, typically 24 Vdc field signals.
- High channel density – Suited for cabinets where I/O count matters; reduces panel footprint and wiring compared to lower-density cards.
- Comprehensive diagnostics – Per-channel status indication and onboard fault detection help pinpoint wiring issues and failing devices faster.
- Deterministic performance – Stable scan behavior for sequence-of-events capture and trip logic; helpful when you need consistent timing across many inputs.
- Hot-swap serviceability – In most cases, modules can be replaced online in a redundant architecture, minimizing process disruption.
- Trusted backplane integration – No external configuration ports; all communications and voting are handled via the Trusted chassis.
- Industrial noise immunity – Designed for harsh electrical environments with proper grounding and shielding practices.
Technical Specifications
| Brand / Model | ICS TRIPLEX Trusted T8314 |
| HS Code | 8538.90 (Parts suitable for electrical control equipment) |
| Function | Safety-grade digital input module for 24 Vdc field signals (within Trusted TMR systems) |
| Power Requirements | Backplane power via Trusted I/O chassis; field input circuits typically 24 Vdc nominal |
| Signal Input/Output Types | Digital inputs, 24 Vdc; high-density card with per-point status/diagnostics (module variant dependent) |
| Communication Interfaces | Trusted system backplane (no external comm ports on the module) |
| Operating Temperature | Typically −20 °C to +60 °C (depends on revision; confirm per datasheet) |
| Installation Method | Plug-in module for Trusted I/O chassis; wiring via separate termination assemblies; hot-swap capable in most systems |
Related or Supporting Products
- T8110 (Trusted TMR controller) – Main processor used with T8314 for SIL3 safety logic. If you’re expanding a cabinet, this is typically the controller we’d match.
- T8400 series (Power supply modules) – Provides chassis/backplane power; choose the input range and redundancy level to suit cabinet design.
- Trusted termination assemblies (TA) – Dedicated marshalling/termination units for DI wiring; select per channel count and field wiring preference.
- Alternative DI variants (e.g., T8310 / T8311 / T8312) – Similar digital input modules that differ by diagnostics, input types or channel density. Useful when standardizing across different process areas.
A maintenance engineer at a refining client told us the T8314 “cut fault-finding time in half” after they enabled the module’s per-point diagnostics and cleaned up shield terminations—small detail, big payoff in a turnaround window.
Installation & Maintenance
- Cabinet & environment – Install in a clean, ventilated control cabinet. Follow Trusted chassis spacing. Maintain ambient within the stated operating temperature and avoid direct heat sources.
- Wiring – Use shielded twisted pairs for long runs or noisy areas. Land shields at one end to avoid loops. Maintain segregation from high-voltage and VFD cables.
- Grounding – Bond cabinet ground to a low-impedance plant earth. Keep termination assembly grounds short and consistent.
- Commissioning – Validate each channel with simulated 24 Vdc signals. Verify diagnostic states and any line monitoring (if configured).
- Hot-swap practice – Where redundancy allows, place the input set in a safe state before swapping. Confirm firmware compatibility with the controller image.
- Routine maintenance – Periodically check terminal tightness, clean dust with dry air, review event logs, and align firmware with the approved baseline. No calibration is typically required for DI.
Quality & Certifications
- Designed for use in SIL3 applications as part of the Trusted TMR platform (TÜV-certified platform; module certification depends on revision)
- CE compliant; UL/CSA listings are available on many revisions
- RoHS compliance varies by hardware revision; we can confirm per serial/PN before shipment
- Manufacturer warranty practices apply; our supply warranty is 365 days
Next Steps
Share your required quantity, cabinet type (rack size/TA type), and field voltage scheme. We’ll match the correct T8314 revision and termination assemblies, confirm lead time (1 week if in stock, not more than a month), and provide a firm quotation with the payment and delivery terms above.







Reviews