Yokogawa YHC5150X HART Communicator – Intrinsically Safe handheld for smart device configuration and troubleshooting
The Yokogawa YHC5150X is a field-proven, intrinsically safe HART communicator designed for commissioning, configuring, and maintaining HART 5/6/7 instruments in the plant or out in the field. From my experience, it’s one of those tools that simply reduces friction: quick device identification, easy parameter edits, and dependable loop communications—even on older wiring. You might notice that it boots fast and stays readable in bright daylight, which helps when you’re balancing on a grating with a radio on one shoulder.
Typical use cases include transmitter zero/span checks during start-up, valve positioner tuning during outages, uploading/downloading device configurations before a turnaround, and pulling detailed device diagnostics to shorten troubleshooting time. One thing I appreciate is the upgradable DD library—staying current with new device revisions without changing hardware is a real cost saver.
Order Placement Process and Guarantees
- Warranty: 365 days
- Delivery: 1 week for in-stock; no more than one month at the latest
- Payment: 50% advance payment, full payment prior to delivery
- Express options: FedEx, UPS, DHL
Key Features
- Full HART coverage (5/6/7): Supports universal, common-practice, and device-specific commands, so you can configure virtually any HART field device.
- Intrinsically Safe handheld: Built for hazardous areas; IS-certified variants enable use in Zone 1 / Class I, Div 1 environments.
- Upgradable DD library: Device Description files can be updated via USB, keeping pace with new transmitter and valve revisions.
- Readable, robust display: Backlit, sunlight-readable screen with a straightforward menu flow—handy in bright outdoor units or dim racks.
- Built‑in 250 Ω loop load (selectable): Ensures proper HART communications on live loops without extra hardware in many cases.
- Burst mode and diagnostics: Access device variables, perform trims, and pull diagnostics to reduce downtime.
- Rugged battery-powered design: Rechargeable Li‑ion pack for field mobility; charge at the shop and it’s ready for a full shift, typically.
- USB connectivity: For DD updates, report export, and maintenance—no special dock required.
“We swapped from a mixed fleet to the YHC5150X for our turnarounds. The techs liked the fast device reads and not having to fight with extra resistors on older loops.” — Maintenance supervisor in a chemicals plant
Technical Specifications
| Brand / Model | Yokogawa YHC5150X HART Communicator |
| HS Code | 9030.89 (Instruments for measuring/checking electrical quantities – other) |
| Power Requirements | Rechargeable Li‑ion battery; charger input 100–240 VAC, 50/60 Hz; USB for updates/maintenance |
| Operating Temperature | 0 to 50 °C (32 to 122 °F), typical field operation range |
| Signal Input/Output Types | HART FSK (Bell 202) over 4–20 mA loop; polarity‑independent test clips; selectable internal 250 Ω load |
| Communication Interfaces | USB device port (DD/firmware updates, data export) |
| Display | Backlit, sunlight‑readable LCD; multi‑line, menu‑driven UI |
| DD Library | Preloaded HART DDs; field‑upgradeable via USB |
| Installation Method | Portable/handheld; connect across the loop at the device or marshalling panel |
| Approvals | Intrinsically Safe versions available (ATEX/IECEx/FM/CSA). Verify exact markings on the unit nameplate for your region. |
| Dimensions & Weight | Compact handheld; approximately 1–1.2 kg including battery (for reference) |
Related or Supporting Products
- Emerson AMS Trex Device Communicator – Similar handheld platform; color touch screen and advanced apps. Good when asset management integration is a priority.
- Emerson 475 Field Communicator – Legacy but still widely used; suitable as a replacement in plants with existing 475 procedures.
- ProComSol HM‑USB‑ISO HART Modem + DevCom software – PC/mobile‑based HART configuration; useful for bench work or when you want reports in PDF fast.
- 24 V loop power supply + 250 Ω resistor kit – For safe bench configuration of loose devices without a DCS/PLC loop.
- Yokogawa FieldMate software – For plant-wide device management, bulk configuration, and audit trails.
Installation & Maintenance
- Connection and wiring: Clip across the 4–20 mA loop at the device or marshalling terminals. Ensure a 250 Ω load is present (use the built‑in selectable load when needed). Polarity is typically non‑critical for HART comms on this unit.
- Cabinet/area conditions: In hazardous locations, only use the intrinsically safe YHC5150X variant within its certified zones. Charge the unit in a safe area; don’t connect the AC charger in classified areas.
- Ventilation and handling: Keep the communicator dry and away from conductive dust. Avoid crushing pressure in tool bags; the display is tough but not indestructible.
- Routine care: Update the DD library periodically via USB; this avoids “unknown device” messages on newer transmitters. Wipe with a soft, non‑solvent cloth, and check leads/clips for oxidation every few months.
- Calibration/verification: The communicator itself does not require calibration, but a quick self‑test on power‑up and a loop comms check before field use is a good habit.
- Battery practices: Fully charge before long field rounds. In most cases, one charge covers a full shift; if you’re logging diagnostics continuously, carry a spare pack.
Quality & Certifications
- Conformity: CE compliant; RoHS alignment typically available for the handheld and charger set.
- Hazardous area approvals: ATEX/IECEx/FM/CSA Intrinsic Safety certifications available by sub‑model; confirm exact coding on the device label for your site standard.
- Manufacturer’s warranty: 1‑year limited warranty (365 days).