Description
Xycom XVME-2122 – VMEbus Digital I/O Module for Discrete Control and Machine Monitoring
The Xycom XVME-2122 is a VMEbus I/O board designed for reliable, rack-mounted discrete signal interfacing. In most cases, you’ll see it used to bring field signals from limit switches, relays, and interlocks into a VME system, or to drive machine signals back out to contactors and lamps. From my experience, the XVME-2122 fits well in brownfield upgrades where you want to keep the VME backplane and modernize the I/O, and it’s also a steady choice for test cells and production lines that need stable, event-driven digital I/O with long service life.
One thing I appreciate is the straightforward integration: standard 6U Eurocard mechanics, VME backplane power, and front-panel connectors that typically make wiring and troubleshooting practical on the plant floor. You might notice that the XVME-2122 family tends to focus on isolation between field and logic—handy if your cabinets mix noisy loads and sensitive control electronics.
Order Placement Process and Guarantees
- Warranty: 365 days
- Lead time: 1 week if in stock; no more than one month at the latest
- Payment terms: 50% advance payment; full payment prior to delivery
- Express options: FedEx, UPS, DHL
Key Features
- 6U VMEbus form factor – Fits standard VME chassis with P1/P2 backplane connectors for quick slot-in installation.
- Industrial-grade digital I/O – Built for discrete sensing and actuation; typically used with switches, relays, contactors, and indicators.
- Field-to-logic isolation – Helps protect the controller from noise and transients in mixed-voltage cabinets.
- Event-driven control – Many deployments leverage change-of-state/interrupt-driven logic to reduce CPU polling overhead.
- Service-friendly indicators – Front-panel status LEDs (on most revisions) simplify commissioning and fault tracing.
- Proven in legacy and mixed systems – Common in long-life VME systems where dependable I/O matters more than flashy features.
Technical Specifications
| Brand / Model | Xycom XVME-2122 |
| HS Code | 8473.30 (Parts and accessories for ADP systems; typical classification for VME I/O boards and may vary by country) |
| Power Requirements | 5 VDC via VME backplane (typical for 6U VME modules; actual consumption depends on configuration) |
| Dimensions & Weight | 6U VME Eurocard, approx. 233 mm x 160 mm; weight typical for a 6U board-form I/O module |
| Operating Temperature | 0 to 55°C (typical for legacy Xycom VME I/O; check specific board revision if you need extended temp) |
| Signal I/O Types | Discrete digital I/O with field-to-logic isolation (used for switches, interlocks, relays) |
| Communication Interfaces | VMEbus backplane interface for register-level control and status |
| Installation Method | 6U VME card; slides into chassis guides; mates with P1/P2 connectors; front-panel field wiring |
Where it’s typically used
- Machine guarding and interlock monitoring in mixed-voltage panels
- Line start/stop logic, lamp/siren control, and operator panel signals
- Fixture and test stand discrete I/O where deterministic response is preferred
A maintenance supervisor told us they keep a few XVME-2122 boards on hand because the modules “just keep running” and swapping one in a live production rack is straightforward. That seems to be the theme with legacy Xycom gear—predictable behavior and easy diagnostics.
Related or Supporting Products
- Xycom XVME-2120 / XVME-2121 – Related digital I/O variants in the same family, often differing by channel count or voltage/isolation details.
- Xycom XVME-240 series – Analog input/output boards if you also need measurement or control beyond discrete signals.
- VME 6U chassis and power supplies – Standard VME backplanes and card cages with adequate airflow and 5 VDC capacity.
- Field wiring breakouts – 50-pin ribbon or D-sub to screw-terminal adapter panels to simplify cabinet wiring and labeling.
Installation & Maintenance
- Cabinet and chassis: Use a VME 6U chassis with proper card guides, ground bonding, and forced-air cooling. Keep intake filters clean.
- Power and grounding: Provide stable 5 VDC on the backplane; separate logic ground from field ground as recommended; avoid shared returns with noisy loads.
- Wiring: Route field I/O in shielded cables where possible; segregate high-voltage or high-current conductors from logic cabling; label channels clearly.
- Safety: De-energize the cabinet before inserting/removing boards; follow ESD precautions; confirm isolation ratings against your field voltages.
- Routine checks: Inspect connectors and terminal blocks quarterly; verify I/O channel operation during planned downtime; tighten any removable terminal screws.
- Firmware/Configuration: Most XVME digital I/O runs at register-level without frequent firmware changes; keep your VME CPU/OS drivers aligned with the board revision.
Quality & Certifications
- CE compliance on many revisions; UL component recognition often applies at the chassis/system level.
- RoHS status can vary by production date; for strict RoHS projects, please confirm the exact board revision.
- Manufacturer quality systems commonly aligned with ISO 9001 practices for legacy Xycom production.
- Standard warranty: 365 days.
Need a quick quote or stock check?
Share your required quantity, target delivery date, and any specific I/O characteristics you must match (voltage levels, isolation, connector type). We’ll confirm availability and the best-fit revision, then arrange shipment via FedEx, UPS, or DHL under the payment terms above.








Reviews