Description
Beijer X2MARINE7 (630002505) – 7-inch marine HMI for bridge, engine room, and harsh-deck operations
The Beijer X2MARINE7, part number 630002505, is a compact 7-inch operator panel built for maritime environments where daylight readability, night-time dimming, and rugged sealing genuinely matter. From my experience, this unit fits neatly into helm consoles and engine room panels where space is tight but the need for a reliable, easy-to-read interface is non-negotiable. You might notice that the front is rated for harsh spray and wash-down, while the dual Ethernet and multi-protocol driver support make integration with PLCs, drives, and navigation/auxiliary systems pretty straightforward.
Company’s Order Placement Process and Guarantees
- Warranty period: 365 days
- Delivery: 1 week if in stock; no more than one month at the latest
- Payment: 50% advance; full payment prior to delivery
- Express options: FedEx, UPS, DHL
Key Features
- Marine-focused 7-inch touchscreen – Optimized for bridge and engine room use, with wide viewing angles and anti-glare front for better readability in changing light.
- Wide-range dimming – High-brightness display with dimming down to near-blackout for night operations where glare is a concern.
- Rugged sealing, front IP66/67 – Handles spray, wash-down, and humid, salt-laden air at the front; suitable for panel mounting on exposed consoles.
- 24 V DC power, marine friendly – Typical 18–32 V DC input with low power draw, which works well on stabilized shipboard supplies.
- Dual Ethernet + serial + USB – Convenient for segregating control networks, connecting to PLCs via RS-232/422/485, and handling data via USB devices.
- Rich driver library – In many cases you can connect to Modbus TCP/RTU, EtherNet/IP, PROFINET device-level comms and more without extra gateways.
- Compact footprint – Fits where space is limited; typically used for local engine readouts, tank/ballast monitoring, and auxiliary systems.
- Designed for low maintenance – Solid-state design, fanless operation, and simple front cleaning routines.
Technical Specifications
| Brand / Model | Beijer Electronics X2MARINE7 (630002505) |
| HS Code | 8537.10 (Boards/panels/consoles for electric control, ≤1000 V) |
| Display | 7-inch TFT widescreen, LED backlight; marine-grade touchscreen; wide dimming range for day/night use |
| Resolution | 800 × 480 pixels (WVGA), typical for this size class |
| Power Requirements | 24 V DC nominal (18–32 V DC), power consumption typically < 15 W |
| Dimensions & Weight | Approx. 197 × 143 × 50 mm (W×H×D); panel cut-out ~189 × 137 mm; weight ~0.9 kg |
| Operating Temperature | -10 to +60 °C (typical for X2 marine units) |
| Ingress Protection | Front IP66/67; rear typically IP20 when panel mounted with supplied gasket |
| Signal I/O Types | Serial COM (selectable RS-232/422/485), USB host ports, memory card slot; digital I/O not typically present on HMI-only variants |
| Communication Interfaces | 2 × Ethernet 10/100 (RJ45), 1 × serial COM, 2 × USB 2.0 host; protocol drivers for Modbus TCP/RTU, EtherNet/IP, PROFINET device (driver availability may vary by project) |
| Installation Method | Panel mounting with gasket and clips (standard); VESA 75 mm adapter options are commonly used when not panel mounting |
Related or Supporting Products
- X2 marine 12 – Larger 12-inch variant with more screen area for trend and mimic views; same marine-grade sealing.
- X2 marine 15 – 15-inch panel for bridge consoles where multiple P&IDs or alarm pages are visible at once.
- X2 pro 7 – Similar 7-inch size, general industrial (non-marine) variant; good alternative when marine approvals aren’t required.
- X2 base 7 – Cost-optimized 7-inch HMI for lighter-duty installations; fewer interfaces and lower brightness in many cases.
- 24 V DC DIN-rail power supply (marine-rated) – Stabilized supply to reduce brownouts; choose models with marine approvals for bridge installations.
- Industrial SD/microSD card – For data logging and recipe backups; SLC or industrial-grade TLC types typically recommended.
Installation & Maintenance
- Mounting & cabinet – Use a rigid marine console/panel with correct cut-out; fit the supplied gasket for IP66/67 front sealing. Avoid panel flex that can break the seal.
- Ventilation – Fanless design; ensure natural convection and avoid direct heat sources behind the panel. In engine rooms, keep ambient within the stated range.
- Wiring – 24 V DC stabilized supply; observe proper grounding and shield terminations for serial/Ethernet runs to minimize EMI common at sea.
- Safety – Power down before servicing. Use drip loops on cables and IP-rated glands where exposed to spray.
- Routine care – Clean the front with fresh water and mild detergent; avoid solvents. Check gasket condition annually and replace if hardened or nicked.
- Software upkeep – Keep HMI project files and firmware up to date. Back up recipes/logs to industrial-grade SD. Many teams schedule a quick calibration check and display dimming test during dry-dock.
Quality & Certifications
- CE and RoHS compliant; UL/cUL listings typically available for the X2 family
- Marine approvals commonly include DNV, LR, ABS, BV, KR, NK, CCS (availability can depend on the exact variant and firmware)
- Designed for marine environmental standards such as IEC 60945 for bridge and deck equipment
- Manufacturer’s warranty: 12 months (365 days)
One thing I appreciate is how often this model drops into existing cut-outs and just works—typical feedback from crews is that the dimming range and the front sealing save hassle during night shifts and wash-downs. If your application needs specific protocol drivers or exact approval certificates for class notation, share the checklist and we’ll confirm against 630002505 before shipment.