PROSOFT MVI56E-MNETCR | large-scale Modbus TCP device connections.

$2,550.00

Brand: ProSoft Technology (owned by Moxa)
Model: MVI56E-MNETCR (CR = Client Reduced data block)

Backplane current: 800 mA @ 5 VDC; 3 mA @ 24 VDC
Operating temperature: 0°C ~ +60°C
Storage temperature: -40°C ~ +85°C
Humidity: 5%–95% RH, no condensation
Diagnosis: LED status indicator + on-board web server

Categories: Tags: SKU: MVI56E-MNETCR
Lily

Need help?
Email: sales@fyplc.cn
Tel/WhatsApp: +86 153 5945 8915

Description

MVI56E-MNETCR is an enhanced Modbus TCP/IP multi-client communication module designed by ProSoft for Rockwell ControlLogix (1756 platform). It focuses on multi-client + small data blocks and is suitable for remote racks and large-scale Modbus TCP device connections.

The product images shown are not actual photos. There are still more models that have not been launched yet.For more details or price negotiations, please contact us: Email: sales@fyplc.cn | WhatsAPP: +86 15359458915

MVI56E-MNETCR
Core positioning
Brand: ProSoft Technology (owned by Moxa)
Model: MVI56E-MNETCR (CR = Client Reduced data block)
Function: Modbus TCP/IP multi-client (master station), also serving as a server; EtherNet/IP ↔ Modbus TCP protocol conversion
Features: Smaller I/O data blocks, suitable for remote racks, ControlNet bridging scenarios Key specifications
Ethernet port: 2×RJ45, 10/100 Mbps, Auto-MDIX
Client capabilities: Up to 30 Clients, each Client up to 16 commands
Server capabilities: Supports 20 Server sessions (running simultaneously)
Modbus function codes: 1/2/3/4/5/6/7/15/16
Data mapping: Maximum 5000 16-bit registers, supports floating point
Backplane current: 800 mA @ 5 VDC; 3 mA @ 24 VDC
Operating temperature: 0°C ~ +60°C
Storage temperature: -40°C ~ +85°C
Humidity: 5%–95% RH, no condensation
Diagnosis: LED status indicator + on-board web server
Model Comparison (Simplified Version)
MVI56E-MNETCR: 30 Clients + 20 Servers, Small Data Blocks, Remote Rack Optimization
MVI56E-MNET: 100 Clients + 20 Servers, Standard Data Blocks
MVI56E-MNETXT: Wide Temperature Range (–25°C ~ 70°C) + Three-Barrier Coating, Extreme Environments

MVI56E-MNETC-3
Core advantages
High-performance multi-client: 30 clients can operate in parallel, suitable for collecting data from dozens to hundreds of Modbus instruments / frequency converters / PLCs in a centralized manner.
Small data blocks (CR): Compared to the standard MNET, the I/O data area is smaller, and the delay and stability are lower and more stable when bridging remote racks / ControlNet.
Dual network ports + Web configuration: Two RJ45 ports can be used for network redundancy; built-in web interface, no need for software configuration and diagnosis.
CIPconnect bridging: Modules can be remotely configured and diagnosed via ControlNet/EtherNet/IP.
Compatible alternatives: Can directly replace the old MVI56-MNETR model without modifying the ladder diagram.

Typical application
Multiple Modbus TCP instruments/sensors in the factory → Centralized monitoring by ControlLogix
Oil and gas / water treatment: Remote pumping stations, instrument rooms – Modbus devices are networked together
Power: Substations’ integrated protection devices, electricity meters, UPS – connected to the Rockwell system
Remote racks (such as 1756-RIO) are connected to the Modbus network via ControlNet

Reviews

There are no reviews yet.

Be the first to review “PROSOFT MVI56E-MNETCR | large-scale Modbus TCP device connections.”

Your email address will not be published. Required fields are marked *

zzfyplc_Lily

Related products