FS-SIF-24 Honeywell FSC Safety Serial Interface & Redundant Feeder Unit

$2,550.00

  • Model: FS-SIF-24, Revision 1.0, Internal part code E168320
  • Brand: Honeywell
  • Warranty: One Year
  • Rated Power Supply: 24 VDC operating voltage, maximum allowable input 31 VDC
Categories: Tags: SKU: FS-SIF-24
Lily

Need help?
Email: sales@fyplc.cn
Tel/WhatsApp: +86 153 5945 8915

Description

FS-SIF-24 Honeywell FSC Safety Serial Interface & Redundant Feeder Unit

Technical Specifications

  • Model: FS-SIF-24, Revision 1.0, Internal part code E168320
  • Brand: Honeywell
  • Warranty: One Year
  • Rated Power Supply: 24 VDC operating voltage, maximum allowable input 31 VDC
  • Main Rated Current: 63A main feeder capacity, auxiliary control current ≤200mA
  • Structure Type: Integrated redundant power feeder + SIF safety serial communication dual-function assembly
  • Output Configuration: 4 independent isolated 24VDC field feeder channels, max 50mA per channel
  • Protection Mechanisms: Channel short-circuit automatic reset protection, surge protection compliant with IEC 61000-4-5, overvoltage/overtemperature cut-off
  • Communication Function: SIF (Serial Interface) isolated serial port for FSC safety system cross-communication
  • PCB Grade: UL94V-0 flame retardant circuit board, full conformal coating
  • Operating Temperature: 0°C ~ +70°C maximum ambient temperature
  • Storage Temperature: -20°C ~ +85°C
  • Dielectric Withstand Voltage: 500V isolation between power circuit and signal circuit
  • Protection Class: IP20 for cabinet internal fixed installation
  • Net Weight: 14.7kg complete assembled unit
  • Compatible System: Honeywell FSC (Fail-Safe Control) ESD/SIS safety instrument system
  • HONEYWELL_TC-CCN014_3

Product Overview

The FS-SIF-24 is a customized integrated redundant feeder and safety serial interface assembly exclusively designed for Honeywell legacy FSC fail-safe safety control system, widely deployed on ESD emergency shutdown and SIS safety interlock systems in petrochemical, oil & gas, fertilizer and thermal power industries.

It combines two core functions in one heavy-duty assembled unit:

  1. Redundant 24VDC Power Feeder Unit: Provides centralized, fault-tolerant 24V DC power distribution for field safety transmitters, limit switches, solenoid valves and proximity sensors; each loop carries independent short-circuit protection to avoid total system power collapse caused by single field wiring fault.
  2. SIF Safety Isolated Serial Interface Module: Acts as a secure isolation gateway between the high-SIL FSC safety controller and non-safety DCS, SCADA host or third-party monitoring systems. It transmits interlock trigger records, equipment trip status and real-time process variables without downgrading the safety integrity level of the core SIS loop.

Reviews

There are no reviews yet.

Be the first to review “FS-SIF-24 Honeywell FSC Safety Serial Interface & Redundant Feeder Unit”

Your email address will not be published. Required fields are marked *

zzfyplc_Lily

Related products