FC‑TSHART‑1620M HART Termination Module

$3,560.00

  • Product Model: FC‑TSHART‑1620M
  • Brand: Honeywell
  • Warranty: One Year
  • Humidity: 5‑95 % RH, non‑condensing
  • Weight: 0.82 kg
Categories: Tags: SKU: FC‑TSHART‑1620M
Lily

Need help?
Email: sales@fyplc.cn
Tel/WhatsApp: +86 153 5945 8915

Description

FC‑TSHART‑1620M HART Termination Module

Technical Specifications

  • Product Model: FC‑TSHART‑1620M
  • Brand: Honeywell
  • Warranty: One Year
  • Input Voltage: 24 V DC field‑loop power, backplane logic power
  • Operating Temperature: 0 °C ~ +60 °C
  • Storage Temperature: ‑40 °C ~ +85 °C
  • Response Time: HART communication cycle dependent on field device
  • Protection Class: IP20 rack‑mount termination assembly
  • Accuracy Class: Process‑control HART signal interface grade
  • Output Frequency: Not applicable
  • Rated Current: 20 mA per channel for 4‑20 mA HART field loops
  • Channel Count: 16‑channel HART‑enabled field termination
  • Function: Provides field‑wiring termination, HART signal coupling for Safety Manager analog input modules
  • Diagnostics: Loop short‑circuit protection, module status LED indicators
  • System Compatibility: Honeywell Safety Manager SIS system
  • Certifications: CE, cULus, SIL3 compatible
  • Humidity: 5‑95 % RH, non‑condensing
  • Weight: 0.82 kg
  • Dimensions: Standard Safety Manager rack‑mount module footprint
  • HONEYWELL_FC-RUSIO-3224_5

Product Overview

FC‑TSHART‑1620M is a 16‑channel HART‑capable termination module for Honeywell Safety Manager SIS platforms. It serves as physical termination interface for HART‑compatible 4‑20 mA field transmitters, coupling analog process signals and HART digital communication signals to corresponding safety I/O modules. Built‑in loop short‑circuit protection prevents field‑side faults from damaging system backplane hardware. This discontinued OEM termination unit is available as refurbished and new‑old‑stock spare parts for petrochemical‑plant SIS‑system upgrade and maintenance work.

Application Notes

‑ Installed inside Safety Manager I/O chassis, matched with corresponding analog input modules. ‑ Follow HART multi‑drop wiring rules when configuring field instrument loops. ‑ ESD anti‑static handling required during installation and replacement. ‑ Typical deployment: refineries, chemical‑plants, oil‑gas‑processing SIS safety‑instrument‑loop spare‑part stocking.

Reviews

There are no reviews yet.

Be the first to review “FC‑TSHART‑1620M HART Termination Module”

Your email address will not be published. Required fields are marked *

zzfyplc_Lily

Related products