TK3 177313-01-01 Proximity System Test Kit

$2,550.00

  • Product Model: TK3 (177313-01-01), electric-driven calibration unit
  • Brand: Bently Nevada (Baker Hughes)
  • Warranty: One Year
  • Power Supply: 95-125 VAC / 190-250 VAC, 50/60 Hz
Categories: Tags: SKU: TK3 177313-01-01
Lily

Need help?
Email: sales@fyplc.cn
Tel/WhatsApp: +86 153 5945 8915

Description

TK3 177313-01-01 Proximity System Test Kit

Technical Specifications

  • Product Model: TK3 (177313-01-01), electric-driven calibration unit
  • Brand: Bently Nevada (Baker Hughes)
  • Warranty: One Year
  • Power Supply: 95-125 VAC / 190-250 VAC, 50/60 Hz
  • Vibration Amplitude Range: 50 µm to 254 µm (2 to 10 mils) peak-to-peak
  • Frequency Range: 0 to 5000 cpm ±1000 cpm (electric drive mode)
  • Micrometer Travel: 0 – 25.4 mm (0 – 1000 mils), English-scale graduation
  • Target Material: AISI 4140 alloy steel wobble plate & target button
  • Operating Temperature: 0 °C ~ +54 °C (32 °F ~ 130 °F)
  • Protection Class: IP54 dust- and splash-resistant portable housing
  • Probe Compatibility: Accepts 5 mm to 19 mm diameter eddy-current proximity probes
  • System Compatibility: Bently Nevada 3300, 7200 and compatible proximity transducer systems
  • Diagnostics: Validates transducer linearity, gain accuracy, loop integrity and fault conditions
  • Humidity: 5-95 % RH non-condensing
  • Weight: 5.22 kg
  • Dimensions: 195 × 299 × 248 mm (H × W × D)
  • TK-CCR014

Product Overview

177313-01-01 TK-3E is a portable, motor-driven proximity transducer calibration and verification test kit. It performs both static displacement calibration via precision spindle micrometer and dynamic vibration simulation via motor-driven wobble plate, enabling field technicians to validate eddy-current probe, extension cable and proximitor system performance without removing machinery probes. Widely deployed in power generation, oil & gas, petrochemical and metallurgical plants for predictive maintenance instrument calibration. Surplus and refurbished tested spare calibrator for instrument workshop maintenance and spare-part stocking.

Application Notes

  • Perform zero-span static calibration first, then dynamic vibration verification following official procedure.
  • Always use matching 4140 steel target to avoid material-property measurement deviation.
  • Keep optical and mechanical components clean; avoid dust and oil contamination on wobble-plate surface.
  • Typical deployment: Proximity transducer system field calibrator spare-part stocking.