WOODWARD 1751‑6058 4‑Channel MPU Transformer Module

$3,560.00

  • Product Model: 1751‑6058
  • Brand: Woodward
  • Warranty: One Year
  • Function: 4‑channel MPU magnetic pickup signal isolation transformer module
Categories: Tags: SKU: 1751‑6058
Lily

Need help?
Email: sales@fyplc.cn
Tel/WhatsApp: +86 153 5945 8915

Description

WOODWARD 1751‑6058 4‑Channel MPU Transformer Module

Technical Specifications

  • Product Model: 1751‑6058
  • Brand: Woodward
  • Warranty: One Year
  • Function: 4‑channel MPU magnetic pickup signal isolation transformer module
  • Input Interface: Multiple magnetic‑pickup speed‑sensor input channels
  • Output Interface: Isolated conditioned speed‑signal outputs for turbine governor control system
  • Power Supply: 24 VDC auxiliary power supply
  • Frequency Response: Matches turbo‑machinery MPU speed‑sensor frequency range
  • Isolation: Galvanic isolation between field MPU side and control‑system logic side
  • Operating Temperature: ‑20 °C ~ +60 °C
  • Storage Temperature: ‑40 °C ~ +85 °C
  • Protection Class: IP20 cabinet‑mount metal enclosure
  • System Compatibility: Woodward turbine governor, generator speed‑control systems for gas‑turbine / steam‑turbine / diesel‑engine prime movers
  • Diagnostics: Signal status monitoring for MPU input circuit fault detection
  • Humidity: 5‑95 % RH non‑condensing
  • Weight: 3.0 kg
  • Dimensions: Standard Woodward cabinet‑mount module footprint
  • woodward_9907-162_digital_governor_4

Product Overview

1751‑6058 is multi‑channel MPU signal isolation transformer module for Woodward speed‑governor systems. It receives raw AC pulse signals from magnetic‑pickup speed sensors on turbines and engines, provides galvanic isolation and signal conditioning, sends conditioned speed‑feedback signals to governor controller for rotational‑speed measurement and closed‑loop speed‑control. Used for gas‑turbine, steam‑turbine and large diesel‑generator control cabinets. Surplus and refurbished tested spare MPU signal‑processing module for power‑generation turbine‑control‑system maintenance projects.

Application Notes

‑ Verify MPU sensor wiring polarity before power‑on. ‑ Check signal amplitude at module input terminals during commissioning. ‑ Observe ESD precautions when handling internal circuit boards. ‑ Typical deployment: Turbine governor MPU transformer module spare‑part stocking.