GE Vernova Hydran M2 Mark III online DGA monitor composite gas moisture in oil transformer fault detector

  • Manufacturer: GE Vernova (Grid Solutions)
  • Model: Hydran M2 (Mark III)
  • Device Type: Transformer DGA & moisture online monitor
  • Sensor type: Fuel cell composite gas / discrete hydrogen sensor
  • Operating temperature: −40°C ~ +55°C
  • Humidity: 5% – 95% non‑condensing
Categories: Tags:
Lily

Need help?
Email: sales@fyplc.cn
Tel/WhatsApp: +86 153 5945 8915

Description

Product Overview The Hydran M2 is a continuous online dissolved gas and moisture-in-oil monitor for power transformers, built on fuel cell sensing technology. It is available in two sensor options: hydrogen-only or composite gas (H₂, CO, C₂H₂, C₂H₄). It detects incipient transformer faults such as overheating, partial discharge and arcing, supports gas level and rate-of-change alarm logic, and can integrate supplementary oil temperature and load sensors for transformer thermal model calculation. It is widely fitted on power grid, generator step-up and industrial distribution transformers for asset health early warning.

Technical Specifications

  • Manufacturer: GE Vernova (Grid Solutions)
  • Model: Hydran M2 (Mark III)
  • Device Type: Transformer DGA & moisture online monitor
  • Sensor type: Fuel cell composite gas / discrete hydrogen sensor
  • Gas measurement range: 0–2000 ppm (H₂ equivalent)
  • Gas accuracy: ±10% of reading ±25 ppm
  • Moisture measurement: 0–100% RH, ±2% RH accuracy
  • Response time: 10 min (90% step change)
  • Display: 128×64 backlit LCD + local keypad for setup and alarm acknowledge
  • Relay outputs: 5 configurable SPDT alarm relays, 3A @250VAC / 3A @30VDC
  • Communication: RS232, isolated RS485; protocols: Modbus RTU, DNP3, Hydran native protocol
  • Supply: 90–132 VAC / 180–264 VAC universal, 47–63 Hz
  • Mounting: 1.5″ NPT male thread, adapter options for 1″ / 2″ transformer oil valve
  • Dimensions: 315 × 219 × 196 mm
  • Weight: 7.5 kg installed
  • Operating temperature: −40°C ~ +55°C
  • Humidity: 5% – 95% non‑condensing
  • Certifications: CE
  • Feature: Built-in oil sampling port, no moving parts, trend logging, configurable level / rate-of-change alarm, compatible with mineral oil

Differentiation Notes Hydran M2 is the classic Mark III unit; Hydran M2-X is the upgraded version with extended sensor lifespan, optional Ethernet and IEC 61850 support, the variant you input earlier (M2-X-O1-S1-A0-B0-C0-D0-P0-G0-VC0-V0-M0-L0). Hydran M2 is phase-out, available as NOS, refurbished and surplus spare parts for transformer monitoring retrofit.

Reviews

There are no reviews yet.

Be the first to review “GE Vernova Hydran M2 Mark III online DGA monitor composite gas moisture in oil transformer fault detector”

Your email address will not be published. Required fields are marked *