ABB 1MRK0023505-AA – Genuine ABB Spare/Accessory for Relion Protection & Control Systems
From my experience, ABB part codes beginning with 1MRK are factory-original spare parts and accessories designed for the Relion protection and control family (typical 615/620/630/650/670 series IEDs). The 1MRK0023505-AA follows the same pattern: a serviced, traceable component intended to maintain form, fit, and function in utility substations and industrial power distribution panels. If you’re planning a like-for-like replacement or stocking critical spares, this is the safe choice—OEM quality, correct tolerances, and consistent compatibility.
Order Placement Process and Guarantees
- Warranty: 365 days
- Lead time: 1 week if in stock; no more than one month at the latest
- Payment: 50% advance payment; full payment prior to delivery
- Express options: FedEx, UPS, DHL
- Authenticity: Supplied as original ABB part with traceable labeling and ESD-safe packaging
- Compatibility check: We typically verify against your IED type code and serial number to avoid mismatches
Key Features
- Genuine ABB spare/accessory: Ensures the same mechanical interface and performance characteristics as the original installed component.
- Fit for Relion platforms: Typically used with ABB protection and control IEDs in the 615/620/630/650/670 ranges—ideal for fleet standardization.
- Service-friendly packaging: Supplied in ESD-safe and clearly labeled bags or cartons for simplified storeroom handling.
- Consistent quality: Manufactured to ABB’s QA standards; seems to be the most reliable way to keep multi-vendor panels stable.
- Lifecycle support: Suitable for corrective maintenance, preventive replacements, and retrofit projects to reduce unexpected downtime.
Technical Specifications
| Parameter | Details |
|---|---|
| Brand / Model | ABB 1MRK0023505-AA |
| Product Category | Original spare part / accessory for ABB Relion protection & control IEDs |
| HS Code | 8538.90 (Parts suitable for apparatus of heading 8535/8536/8537) |
| Power Requirements | No external power; if applicable, supplied by the host IED |
| Dimensions & Weight | Compact service part; typically lightweight for panel service logistics (packaged mass commonly below 0.5 kg) |
| Operating Temperature | Follows the host IED’s environmental rating; use within the same cabinet conditions as the target device |
| Signal I/O Types | Not applicable for standalone use; function is defined by the host IED |
| Communication Interfaces | Not applicable independently; interface behavior depends on the IED slot/function where installed |
| Installation Method | Plug-in replacement/kit installation according to ABB Relion service instructions; follow ESD precautions |
Application Fields
You might notice that maintenance teams prefer OEM-coded parts for mission-critical substations. This part code is typically stocked for:
- Transmission and distribution substations using ABB Relion IEDs
- Industrial power systems (metals, mining, oil & gas, data centers) with ABB feeder/transformer protection
- Retrofit and life-extension programs where compatibility and certification records matter
Advantages & Value
- Reliability: Original ABB sourcing reduces variability across panels and prevents nuisance faults after maintenance.
- Compatibility: Fit-for-purpose with Relion hardware; avoids engineering re-approval that often comes with substitutes.
- Cost control: Minimizes rework and truck rolls—one thing I appreciate is how these OEM parts shorten outage windows.
- Traceability: Complete part coding for audit, QA, and future spares planning.
- Support: We can align delivery with planned shutdowns; in many cases, advanced shipment notices help your crews stage work.
Installation & Maintenance
- Environment: Install within a sealed switchgear/control cabinet that meets the IED’s specified humidity and temperature ranges; keep ventilation unobstructed.
- Wiring: Follow the specific Relion manual for terminal labeling and torque values; isolate control power and trip circuits before work.
- ESD safety: Use grounded wrist straps and antistatic matting; do not remove protective packaging until at the panel.
- Verification: After installation, perform self-tests/diagnostics on the IED and check event logs for errors or warnings.
- Routine care: Periodically inspect connectors and mounting points; keep the cabinet free from dust; schedule firmware checks on the host IED when applicable.
Quality & Certifications
- Typically conforms to ABB’s CE marking where applicable for the host equipment
- RoHS-compliant components and packaging practices in most cases
- Manufactured under ISO 9001 quality management systems
- One-year warranty coverage (365 days) from shipment
Helpful Notes from the Field
A utility customer recently mentioned the swap was “plug-and-play” once we matched the IED type code. That seems to be the norm with ABB-coded parts—minimal recalibration and no surprises during commissioning. If you share your IED type (e.g., REL615, REF630) and serial, we’ll validate 1MRK0023505-AA fitment before you place the order.