ABB 3BSE018741R15 – System 800xA / S800 I/O Plug‑in Module for AC 800M Racks

Brand / Model ABB – 3BSE018741R15 (System 800xA / S800 I/O module)
HS Code 853710 (Programmable controller modules)
Power Requirements 24 VDC via S800 backplane (module electronics power)
Dimensions & Weight S800 plug‑in form factor; single‑width module; ~0.2 kg class (typical)
Operating Temperature 0…55 °C cabinet ambient (typical for S800 I/O)
Signal I/O Types Module‑specific; field connections through the S800 terminal base (TU/TB series)
Communication Interfaces ABB ModuleBus/backplane interface to AC 800M; no user Ethernet on the module body
Installation Method Plugs onto S800 terminal base on DIN rail; front connector/labeling for field terminations
Categories: Tags:
contact qrcode

Need help?
Email: sales@fyplc.cn
Tel/WhatsApp: +86 173 5088 0093

Description

ABB 3BSE018741R15 – System 800xA / S800 I/O Plug‑in Module for AC 800M Racks

ABB part 3BSE018741R15 is a System 800xA spare used with AC 800M/S800 I/O racks. From my experience, plants keep this module as a like‑for‑like replacement to restore a faulty slot without touching field terminations or re‑engineering the terminal base. You might notice it follows the familiar S800 form factor with front diagnostics and backplane power, so swap‑outs during a short outage are typically quick and predictable.

ABB 3BSE018741R15 System 800xA S800 I/O module

Company’s Order Placement Process and Guarantees

  • Warranty period: 365 days
  • Delivery time: 1 week for in‑stock; no more than one month at the latest
  • Payment method: 50% advance payment, full payment for delivery
  • Express delivery methods: FedEx, UPS, DHL
  • Process: Confirm model and quantity → Proforma Invoice → Advance payment → Functional testing and packing → Final payment → Express shipment with tracking

Key Features

  • Drop‑in S800 replacement – Fits the standard S800 terminal base so field wiring typically stays untouched.
  • Backplane‑powered – Draws 24 VDC via the rack; no separate supply wiring to the module body.
  • Front diagnostics LEDs – Quick visual status makes loop checks and fault isolation faster.
  • Configuration continuity – In many cases, parameters remain in the controller; like‑for‑like swaps keep addressing stable.
  • Robust cabinet behavior – Designed for noisy industrial panels when grounding and segregation are done properly.

Technical Specifications

Brand / Model ABB – 3BSE018741R15 (System 800xA / S800 I/O module)
HS Code 853710 (Programmable controller modules)
Power Requirements 24 VDC via S800 backplane (module electronics power)
Dimensions & Weight S800 plug‑in form factor; single‑width module; ~0.2 kg class (typical)
Operating Temperature 0…55 °C cabinet ambient (typical for S800 I/O)
Signal I/O Types Module‑specific; field connections through the S800 terminal base (TU/TB series)
Communication Interfaces ABB ModuleBus/backplane interface to AC 800M; no user Ethernet on the module body
Installation Method Plugs onto S800 terminal base on DIN rail; front connector/labeling for field terminations

Application Fields

Common in System 800xA cabinets where dependable I/O and communications are essential:

  • Power generation: boiler/turbine auxiliaries under AC 800M control
  • Oil & gas and petrochem: E&I cabinets with S800 I/O marshalling
  • Pulp & paper, water, mining: brownfield expansions and maintenance swaps
  • OEM process skids integrating with plant‑wide 800xA

Advantages & Value

  • Reliability: Like‑for‑like replacements typically clear intermittent module faults and stabilize signals.
  • Compatibility: Matches the S800 terminal base and ModuleBus—no rewiring in most cases.
  • Downtime savings: Fast swap helps avoid engineering changes or cabinet rework.
  • Support: We can power‑up test, check basic LED/status, and share a short report prior to shipment.
“Replaced the suspect slot with 3BSE018741R15. Addressing stayed intact, LEDs looked right away, and our loop checks finished ahead of schedule.” — I&C technician, combined‑cycle unit

Installation & Maintenance

  • Cabinet setup: Mount on the S800 DIN rail/terminal base; keep ventilation paths clear.
  • Handling: ESD protection; avoid flexing the PCB; verify terminal base part number and keying before insertion.
  • Wiring: Field conductors remain on the terminal base; confirm labeling matches your I/O list.
  • Commissioning: Check LEDs, scan in the controller, and run a brief loop/health test before handover.
  • Routine care: Quarterly dust removal, connector reseat checks, and review of diagnostic logs for early warnings.
  • Safety: De‑energize as per site procedure; follow lock‑out/tag‑out and ESD guidelines.

Quality & Certifications

  • Quality system: Produced under ISO 9001 processes (typical for ABB System 800xA hardware).
  • Compliance: Suitable for CE/UL compliant control panels; RoHS status may vary by production year.
  • Warranty: 365‑day warranty from shipment date.

If you can share your AC 800M controller type, terminal base (TU/TB) part number, and the slot function, we’ll double‑check 3BSE018741R15 compatibility and provide a concise functional test record before dispatch.

Reviews

There are no reviews yet.

Be the first to review “ABB 3BSE018741R15 – System 800xA / S800 I/O Plug‑in Module for AC 800M Racks”

Your email address will not be published. Required fields are marked *

zzfyplc_Lily

Related products