ABB CI868K01 (3BSE048845R1) — High-Integrity Redundant Communication Interface for AC 800M DCS
Let’s cut to the point: the CI868K01 isn’t just another fieldbus adapter — it’s the go-to redundancy-enabling communication module for ABB’s AC 800M distributed control systems, especially where uptime and deterministic data exchange matter. From my experience supporting retrofit projects in pulp & paper mills and offshore platforms, this module consistently handles dual-channel Profibus DP master duties while maintaining hot-swap capability and seamless failover. One customer in Norway told us their boiler control loop stayed online through three consecutive controller switchover events — no operator intervention, no alarms beyond status logging.
Key Features
- Dual redundant Profibus DP Master ports — each port supports up to 126 slaves with configurable baud rates (9.6 kbps to 12 Mbps); redundancy is automatic and transparent to the application logic.
- Tight integration with AC 800M controllers — uses native S800 I/O addressing and appears as a logical extension of the controller’s I/O map, not an external gateway.
- Hot-swappable with state retention — you can replace it mid-operation without resetting the controller or losing process data (though firmware updates still require a brief pause).
- Built-in diagnostics and LED status per channel — includes real-time bus health monitoring, CRC error counters, and slave response timing — useful when troubleshooting intermittent field device dropouts.
- Supports Profibus DP-V1 functionality — meaning it handles acyclic data reads/writes (e.g., parameter uploads from VFDs), which many legacy DP-V0 modules don’t.
Technical Specifications
| Parameter | Specification |
|---|---|
| Brand / Model | ABB CI868K01 (3BSE048845R1) |
| HS Code | 8537.10 — Boards, panels for industrial control systems |
| Power Requirements | Supplied via backplane (AC 800M rack); typical draw: 1.2 A @ 5 V DC |
| Dimensions & Weight | 132 × 112 × 125 mm (W×H×D); ~620 g |
| Operating Temperature | 0 °C to +60 °C (derated above +45 °C in high-convection cabinets) |
| Signal Input/Output Types | Two isolated RS-485 Profibus DP ports (DB9 male, screw terminal option available) |
| Communication Interfaces | Profibus DP-V0/V1 Master; supports GSD file import via Control Builder M |
| Installation Method | DIN-rail mounted in AC 800M S800 I/O rack; requires compatible power supply and base unit (e.g., S800 I/O base 3BSE013190R1) |
Application Fields
This module shows up most often where legacy Profibus field devices (like Siemens SINAMICS drives, Endress+Hauser transmitters, or Pepperl+Fuchs safety barriers) need reliable, fault-tolerant integration into modern ABB DCS environments. Think water treatment plants upgrading SCADA while keeping existing motor control centers intact — or pharmaceutical cleanroom HVAC systems where a single bus failure could trigger batch rejection. It’s also common in brownfield refinery upgrades, where replacing every field device isn’t feasible, but controller-level redundancy is non-negotiable.
Advantages & Value
You’re not buying just a module — you’re buying compatibility assurance and reduced integration risk. Unlike third-party gateways, the CI868K01 ships with pre-validated GSD files and full support in Control Builder M’s hardware configuration tree. That typically saves 2–3 days per project during commissioning. From a procurement standpoint, its 365-day warranty (standard across our ABB inventory), consistent lead time (1 week if in stock), and avoidance of custom engineering quotes make budgeting predictable. And yes — it interoperates cleanly with older CI868 variants (e.g., K01 vs K02), though firmware version alignment matters for V1 features.
Installation & Maintenance
Mount only in ABB-certified S800 I/O cabinets with adequate airflow — we’ve seen thermal throttling kick in when ambient exceeds 55 °C *and* cabinet fans are clogged. Keep cable runs under 100 m for 12 Mbps operation; use shielded twisted pair (STP) with proper grounding at one end only. For maintenance: verify bus termination switches are set correctly (ON for last node, OFF elsewhere), check LED patterns quarterly (steady green = OK, blinking amber = retrying comms), and plan firmware updates during scheduled outages — they’re not disruptive, but require a soft controller restart. Calibration isn’t applicable here, but periodic GSD file version audits help avoid surprises during system backups.
Quality & Certifications
The CI868K01 carries CE (EMC & LVD), UL 61010-1, ATEX II 3G Ex nA IIC T4 Gc, and RoHS 3 compliance — all documented in ABB’s type test reports (available on request). It’s manufactured under ISO 9001:2015 and ISO 14001:2015 certified processes. Our standard warranty is 365 days from delivery date — covers defects in materials and workmanship, including replacement or repair at ABB-authorized service centers. No restocking fees. No hidden clauses.
Our Order Placement Process & Guarantees:
• Warranty: 365 days
• Delivery: 1 week for in-stock units; ≤30 days maximum (including customs clearance)
• Payment: 50% advance, balance before shipment
• Shipping: FedEx, UPS, or DHL Express — fully tracked, insured, with commercial invoice







Reviews