ABB DI831 (3BSE013212R1) – S800 I/O Digital Input Module for 24 V DC field signals

1 Brand: ABB
2 Model: DI831 (3BSE013212R1)
3 Quality: Original module
4 Warranty: 1 year
5 Delivery time: 1 week in stock
6 Condition: New/Used
7 Shipping method: DHL/UPS

Categories: Tags:
contact qrcode

Need help?
Email: sales@fyplc.cn
Tel/WhatsApp: +86 173 5088 0093

Description

ABB DI831 (3BSE013212R1) – S800 I/O Digital Input Module for 24 V DC field signalsDI831-3BSE013212R1

The ABB DI831 3BSE013212R1 is a digital input module in the S800 I/O family, typically used with AC 800M–based control systems and S800 I/O stations. From my experience, it’s a reliable choice when you need clean, stable 24 V DC input collection from machines, valves, proximity sensors, or interlocks—without adding complexity to your cabinet. You might notice that it drops neatly onto a TU8xx terminal base, so expansion and replacement are fast and predictable.

Company’s Order Placement Process and Guarantees

    • – Warranty period: 365 days
    • – Delivery time: 1 week for in-stock items; no more than one month at the latest
    • – Payment: 50% advance payment; full payment prior to delivery
    – Express delivery methods: FedEx, UPS, DHL

Key Features

  • 24 V DC digital inputs – Designed for standard industrial sensors and dry contacts; stable detection in most plant environments.
  • S800 I/O form factor – Plugs onto TU8xx terminal bases on DIN rail, making installation straightforward and service-friendly.
  • Per-channel status indication – Onboard LEDs typically help technicians verify input states quickly during commissioning.
  • Diagnostics and fault reporting – It seems to be well-behaved with channel- and module-level diagnostics, helping reduce troubleshooting time.
  • ModuleBus connectivity – Integrates into AC 800M systems via S800 I/O ModuleBus; easy to scale and mix with AI/DI/DO/AO modules.
  • Field power flexibility – Uses field 24 V DC for input circuits while the module electronics are powered via the backplane.
  • Hot-swap capability (within S800 I/O rules) – In many cases, you can replace modules with minimal process interruption.

Technical Specifications

Brand / Model ABB DI831 (3BSE013212R1)
HS Code 853890 (parts for electrical control equipment) — commonly used for I/O modules
Power Requirements Module electronics powered via S800 ModuleBus; field inputs use external 24 V DC
Dimensions & Weight Standard S800 module footprint (approx. 45 × 119 × 104 mm; typical module mass ~0.18–0.22 kg)
Operating Temperature Typically 0…+55 °C in S800 I/O cabinets (observe de-rating and enclosure ventilation)
Signal Input/Output Types 24 V DC digital inputs (multi‑channel), with status LEDs and diagnostic reporting
Communication Interfaces S800 I/O ModuleBus (for use with AC 800M via communication interfaces such as CI801/CI840A/CI854A)
Installation Method DIN-rail via TU8xx terminal base (e.g., TU810/TU812/TU814 series); front-pluggable module

Application Fields

Typically specified in distributed control and high-availability PLC architectures where you need many 24 V DC inputs in compact cabinets:

  • Process industries: water/wastewater skids, chemical dosing, boiler/burner management interlocks
  • Factory automation: packaging line sensors, conveyor logic, safety interlock monitoring (per system design)
  • Power and utilities: switchgear status feedback, breaker auxiliary contacts, valve/actuator feedback
  • Marine and mining: ruggedized cabinets reading proximity switches and limit switches

Advantages & Value

  • Reliability – S800 I/O modules are widely deployed; the DI831 typically runs for years with minimal attention.
  • Compatibility – Seamless with AC 800M and S800 I/O networks; mixes alongside AI/DO/AO without surprises.
  • Lower lifecycle cost – Hot-swap serviceability and clear diagnostics shorten downtime and technician hours.
  • Spare parts strategy – Same form factor across S800 I/O reduces stocking burden; easy field replacement.
  • Technical support – Documentation and tooling around S800 I/O are mature; engineers typically ramp fast.

One thing I appreciate is how quickly maintenance teams can trace a wiring issue using the channel LEDs and the clear terminal labeling on TU bases. A maintenance lead at a food & beverage plant told us they swapped a DI831 during production changeover “in under 5 minutes” without reworking any harnesses.

Installation & Maintenance

  • Cabinet & mounting – Mount on DIN rail using a compatible TU8xx terminal base. Keep adequate ventilation; avoid heat sources. Follow S800 I/O grounding and shielding practices.
  • Wiring – Use correctly rated 24 V DC field power for inputs. Separate signal and power wiring where possible; observe polarity and the terminal base connection map.
  • Safety – De-energize the affected circuits before inserting or removing wiring. Hot swapping modules should follow ABB S800 procedures and your site’s MOC/LOTO policy.
  • Routine checks – Periodically verify terminal torque, clean dust from module fronts, and review diagnostics in the DCS/PLC. Firmware management is typically handled at controller/communication module level.
  • Spare handling – Store modules in anti-static packaging, in a dry environment. Keep one spare per cabinet row for critical lines.

Quality & Certifications

  • Manufacturer quality system: ISO 9001
  • Conformity: CE
  • Safety approvals: cULus (typically for S800 I/O family)
  • Environmental: RoHS compliant
  • Warranty: 365 days

Related and Supporting Components

  • Terminal bases – TU810, TU812, TU814 (selection depends on wiring density and isolation grouping)
  • ModuleBus accessories – ModuleBus terminators and power feed units for S800 I/O segments
  • Communication interfaces – CI801/CI840A/CI854A for linking S800 I/O to AC 800M or higher-level networks

If you’re matching an existing installation, share a photo of the terminal base and current module sticker—this typically helps confirm keying and wiring compatibility on the first pass.

Reviews

There are no reviews yet.

Be the first to review “ABB DI831 (3BSE013212R1) – S800 I/O Digital Input Module for 24 V DC field signals”

Your email address will not be published. Required fields are marked *

zzfyplc_Lily