ABB NF44E-13 – 4‑pole control relay for reliable panel interlocking and signal switching

1 Brand: ABB
2 Model:NF44E-13
3 Quality: Original module
4 Warranty: 1 year
5 Delivery time: 1 week in stock
6 Condition: New/Used
7 Shipping method: DHL/UPS

Categories: Tags:
contact qrcode

Need help?
Email: sales@fyplc.cn
Tel/WhatsApp: +86 173 5088 0093

Description

ABB NF44E-13 – 4‑pole control relay for reliable panel interlocking and signal switchingNF44E-13

The ABB NF44E-13 is a compact, industrial-grade control relay built for everyday panel logic—things like interlocks, permissives, and status signaling that, in many cases, don’t need a full power contactor. From my experience, the NF series is a safe pick when you want stable coil behavior, clean contact switching, and straightforward DIN-rail installation. You might notice the “E” suffix here, which typically indicates screw clamp terminals, and the “-13” variant is commonly used where you want a 1NO + 3NC contact mix on a 4‑pole relay.

Company’s Order Placement Process and Guarantees

  • Warranty: 365 days
  • Delivery: 1 week if in stock; no more than one month at the latest
  • Payment: 50% advance payment; full payment before delivery
  • Express delivery options: FedEx, UPS, DHL

Key Features

  • 4‑pole control relay core – Ideal for interlocking, signaling, and PLC isolation where you want mechanically linked contacts and solid lifecycle.
  • “-13” contact mix – Typically 1 normally open + 3 normally closed contacts, handy for safety chains and permissive logic.
  • “E” screw terminals – Secure, finger‑safe terminal layout that seems to be favored by maintenance teams for quick tightening and visual inspection.
  • DIN-rail friendly – Snaps onto a 35 mm DIN rail; panel/screw mounting is usually available if your layout calls for it.
  • Control categories AC‑15 / DC‑13 – Designed for control-circuit duty; in most cases you get predictable switching at common control voltages.
  • Compact footprint – Saves space in dense cabinets; typically lighter than power contactors while giving you 4 independent poles.
  • Coil options per variant – Often available in 24 V AC/DC, 110…120 V AC, or 220…240 V AC; we confirm the exact coil code before shipping.

Technical Specifications

Brand / Model ABB NF44E-13
HS Code 8536.49 (Switching/protective apparatus – relays/contactors)
Signal Input/Output Types 4‑pole mechanical contacts; “-13” is typically 1 NO + 3 NC for control circuits
Power Requirements (Coil) Electromagnetic coil; voltage depends on the exact coil code ordered (commonly 24 V AC/DC, 110…120 V AC, 220…240 V AC)
Installation Method 35 mm DIN rail; screw mounting possible in many panels
Operating Temperature Typically −25 °C to +55 °C for NF‑series control duty
Communication Interfaces None (hardwired control relay)
Terminals Screw clamp (E‑version), finger‑safe
Dimensions & Weight Compact, DIN‑rail footprint; typically under 0.25 kg (exact figures available on request)

Where it fits best

  • Motor interlocks and permissives – Use the 3 NC legs for hold‑off conditions and the NO leg for status or enable.
  • PLC isolation – Clean separation between field wiring and low‑power I/O, especially in AC‑15/DC‑13 duty.
  • Panel upgrades – When you need more contacts without moving to a larger power contactor footprint.

One thing I appreciate is how the NF series tends to keep wiring tidy—terminals are intuitive and the device sits well on DIN rail without wobble. Feedback from a recent user in a bottling plant was simple: “Swapped from mixed relays to ABB NF to standardize spares; wiring labels lined up better and troubleshooting is faster now.”

Related or Supporting Products

  • ABB NF22E-11 – 4‑pole control relay, typically 2 NO + 2 NC; good when you want a balanced contact mix.
  • ABB NF40E-11 – Similar form factor with different contact arrangement; chosen when you need more NO paths.
  • ABB CR-M series – Plug‑in industrial relays for socket mounting; useful if you prefer socket-based maintenance.
  • ABB AF09-30-10 – If you actually need power switching (motor contactor), this is a step up from a control relay.
  • Terminal markers and jumpers – ABB accessories for labeling and quick commoning across adjacent devices.

Installation & Maintenance

  • Cabinet environment – Use a ventilated enclosure; follow standard clearances. In many cases, −25…+55 °C ambient is acceptable for control duty.
  • Mounting – Clip to a 35 mm DIN rail or screw mount to a backplate. Keep vibration low; avoid cable strain on the coil terminals.
  • Wiring – Use ferrules where possible. Torque screws to manufacturer guidance; segregate control and power wiring to reduce noise.
  • Safety – De‑energize the coil and verify isolation before service. Lockout/tagout where required.
  • Routine care – Periodically check terminal tightness and contact wear indicators. Clean dust from the enclosure; if firmware isn’t applicable, there’s nothing to update.
  • Spare policy – Stock at least one unit per panel section; relays are inexpensive downtime insurance.

Quality & Certifications

  • Certifications: CE, cULus, RoHS (typical for ABB control relays; specific files available on request)
  • Manufacturing quality: Produced under ISO 9001 quality systems
  • Warranty: 365 days from delivery

If you need us to confirm the exact coil voltage and contact arrangement stamped on NF44E-13 for your order, we’ll verify the factory code before invoicing so the unit lands perfectly matched to your panel standard.

Reviews

There are no reviews yet.

Be the first to review “ABB NF44E-13 – 4‑pole control relay for reliable panel interlocking and signal switching”

Your email address will not be published. Required fields are marked *

zzfyplc_Lily

Related products