Description
(ABB) PU512 V2 – Industrial Panel Unit for high-reliability HMI/soft-control (Order code: 3BUR001401R1)

The PU512 V2 is a compact Panel Unit that pairs with B&R Automation Panel displays to deliver robust HMI and soft-control performance on the factory floor. From my experience, it’s a solid fit when you need an embedded 24 VDC computing core with industrial-grade Ethernet and USB in a space-saving form factor. You might notice that the ABB ordering code 3BUR001401R1 shows up in spares databases—this is the same PU512 V2 hardware sourced through ABB’s B&R channel.
Our Order Placement Process and Guarantees
- Warranty: 365 days
- Delivery: Typically 1 week if in stock; not more than one month at the latest
- Payment: 50% advance payment; full payment prior to delivery
- Express: FedEx, UPS, DHL
Key Features
- 24 VDC industrial power input – Designed for control cabinets; typically 18–30 VDC tolerance for stable operation.
- Compact rear-mount design – Attaches directly to compatible B&R Automation Panel displays, saving panel depth and wiring effort.
- Dual Ethernet ports – Commonly used for segregating plant network and machine network, or simple daisy-chain topologies.
- USB and service interfaces – Fast data transfer for recipes/logs; simple service access for commissioning tools.
- Industrial temperature rating – Typically 0…+50°C operation in a ventilated cabinet; suitable for most shop-floor environments.
- Maintenance-friendly – Front-end visualization and soft-control in one unit; quick swap minimizes downtime.
- ABB/B&R code alignment – Listed as PU512 V2 with ABB order code 3BUR001401R1 for straightforward procurement.
Technical Specifications
| Brand / Model | (ABB) PU512 V2 – Order code 3BUR001401R1 |
| HS Code | 8471.50 (Industrial processing unit, typical classification) |
| Power Requirements | 24 VDC nominal (typically 18–30 VDC), power draw ~25–40 W depending on configuration |
| Dimensions & Weight | Approx. 190 × 140 × 60 mm; ~1.0 kg (varies slightly by hardware revision) |
| Operating Temperature | 0…+50°C (cabinet-mounted, with adequate ventilation) |
| Signal Input/Output Types | No integrated analog/digital I/O; host interfaces via Ethernet/USB/serial; field I/O through external PLCs or networked I/O |
| Communication Interfaces | Typically 2× Ethernet (10/100/1000), 2× USB, 1× serial (RS‑232 for service); options vary by build |
| Installation Method | Rear-mount to compatible B&R Automation Panel; cabinet installation (IP20), grounding to panel backplate |
Notes: Interfaces and consumption can differ slightly by PU512 V2 variant; check your exact build code if you need a one-to-one port match.
Application Fields
This unit is typically used as the compute core behind an industrial touchscreen where reliability matters more than raw PC specs. I see it most in:
- Packaging and F&B lines – machine HMI with recipe handling and data logging
- Automotive assembly – operator terminals, traceability dashboards, station control
- Printing, converting, and textiles – web handling visualization with quick changeovers
- Material handling – conveyor HMI, diagnostics, light soft-control tasks
- Process skids – compact front-end for skids with PLCs and networked I/O
A maintenance lead shared that swapping a PU512 V2 took under 15 minutes—“four screws, two plugs, and we were back online.” That seems to be the typical experience when a plant standardizes on B&R panels.
Advantages & Value
- Reliability in production – Fanless, 24 VDC, and cabinet-rated hardware reduce nuisance downtime.
- Compatibility – Designed for B&R Automation Panel ecosystem; easy fit in brownfield upgrades using ABB code 3BUR001401R1.
- Simplified spares – One compact module to keep on the shelf; faster MTTR compared with full panel PC replacements.
- Total cost – Lower integration time and straightforward wiring usually cut commissioning hours.
- Technical support – Documentation and firmware tools are stable; lifecycle guidance available through ABB/B&R channels.
Installation & Maintenance
- Environment – Install in an IP20 control cabinet with adequate ventilation. Keep ambient within 0…+50°C and avoid vibration hot-spots.
- Power & grounding – Use a clean 24 VDC supply with proper grounding and surge protection. Separate signal and power wiring where possible.
- Mounting – Rear-mount to a compatible Automation Panel; secure all captive screws evenly to avoid connector stress.
- Networking – Use industrial-grade Ethernet cables; label machine vs plant network ports to prevent mix-ups during service.
- Routine care – Periodically clear cabinet dust, check connector torque, and back up application images. Firmware/runtime updates should be scheduled during planned downtime.
Quality & Certifications
- Certifications: CE, cULus, RoHS (typical for B&R PU series)
- Protection: IP20 (when cabinet-mounted)
- Warranty: 12 months (365 days) from delivery
If you can share your current panel model and the exact port requirements, I can double-check the PU512 V2 build against 3BUR001401R1 and confirm a one-to-one replacement, including lead time from the nearest logistics hub.