ABB TB826 – Terminal Base for S800 I/O, clean field wiring and stable ModuleBus connection

1 Brand: ABB
2 Model: TB826
3 Quality: Original module
4 Warranty: 1 year
5 Delivery time: 1 week in stock
6 Condition: New/Used
7 Shipping method: DHL/UPS

Categories: Tags:
contact qrcode

Need help?
Email: sales@fyplc.cn
Tel/WhatsApp: +86 173 5088 0093

Description

ABB TB826 – Terminal Base for S800 I/O, clean field wiring and stable ModuleBus connectionTB826

The ABB TB826 is a terminal base used with the ABB S800 I/O family. From my experience, it’s chosen when you want dependable field terminations on a compact 35 mm DIN rail, while keeping the ModuleBus backplane intact for the pluggable I/O modules. You might notice that it reduces panel wiring clutter and makes module swaps far quicker—typically a few minutes, without disturbing the field conductors.

Order Placement Process and Guarantees

  • Warranty: 365 days
  • Delivery: 1 week if in stock; no more than one month at the latest
  • Payment: 50% advance payment, full payment before delivery
  • Express options: FedEx, UPS, DHL

Key Features

  • Dedicated S800 I/O base – Provides the field terminal interface and backplane contacts for ABB S800 I/O modules.
  • DIN-rail snap-on installation – 35 mm DIN rail mounting keeps cabinet builds fast and tidy.
  • Stable ModuleBus continuity – Maintains the internal bus connection so modules can be inserted or replaced cleanly.
  • Neat field terminations – Typically supports 0.5–2.5 mm² conductors; simplifies routing for analog and digital signals.
  • Service-friendly layout – One thing I appreciate is the clear separation between backplane and field wiring; it helps during maintenance and troubleshooting.
  • Compact footprint – Saves cabinet width, which in many cases lets you fit higher I/O density per panel.

Technical Specifications

Brand / Model ABB TB826
HS Code 853890 (Parts for electrical control equipment)
Power Requirements Passive terminal base; no separate power input (power is provided via the S800 ModuleBus through the mated I/O module)
Operating Temperature Typically 0 to +55 °C, non-condensing environment
Signal I/O Types Supports field terminations for analog and digital channels as defined by the pluggable S800 I/O module (e.g., AI, AO, DI, DO)
Communication Interfaces ModuleBus backplane contacts (no external communication ports on the base)
Installation Method 35 mm DIN rail mounting inside a control cabinet; front-access wiring
Typical Wiring Capacity 0.5–2.5 mm² (AWG 20–14) stranded with ferrules, depending on terminal type
Mechanical Footprint Compact S800 I/O base width (≈45 mm module width typical for this family)

Related / Supporting Products

  • ABB S800 I/O Modules – AI810A (Analog Input), AO810V2 (Analog Output), DI810 (Digital Input), DO810 (Digital Output). These plug into the terminal base to define the channel function and quantity.
  • Communication Interfaces – CI854A (PROFIBUS DP), CI869 (PROFINET). They connect S800 I/O to higher-level controllers or networks.
  • Controllers – AC 800M series (e.g., PM864). In most cases, used as the main controller hosting the I/O and fieldbus interfaces.
  • Alternative base styles – If you need different terminal styles or channel grouping, ABB offers other S800 terminal units/bases in the same family; selection typically depends on wiring preference and module type.

A maintenance lead at a food & beverage plant told us that switching to ABB’s S800 base style shaved a noticeable amount of time from changeovers—mainly because field terminations stayed put while the technician swapped the module.

Installation & Maintenance

  • Cabinet environment – Install on a 35 mm DIN rail inside an industrial enclosure (IP54 or better recommended). Allow ventilation space above and below the row.
  • Wiring practices – Use ferruled conductors; separate low-level analog from inductive loads; route shielded cables to a defined grounding point. Tighten terminal screws to the recommended torque.
  • Grounding & shielding – Keep a clean earth reference; bond cable shields at the cabinet side as per site EMC policy. You might notice that stable grounding reduces intermittent noise on analog channels.
  • Module handling – De-energize the segment before inserting/removing I/O modules. Protect backplane contacts from dust and ESD.
  • Routine checks – Periodically re-check terminal torque, clean dust with dry air, and visually inspect for discoloration or loose strands. Firmware updates apply to the I/O module, not the passive base.

Quality & Certifications

  • Certifications – CE compliant; typically UL/cUL listed and RoHS conformant for S800 I/O family components.
  • Manufacturer Warranty – Backed by a 365-day warranty from shipment.

Reviews

There are no reviews yet.

Be the first to review “ABB TB826 – Terminal Base for S800 I/O, clean field wiring and stable ModuleBus connection”

Your email address will not be published. Required fields are marked *

zzfyplc_Lily