Description
ALSTOM MFAC14K1AA0001A – Plug‑In Control Module for ALSTOM Rack Systems
The ALSTOM MFAC14K1AA0001A is a rack plug‑in control module used in legacy ALSTOM automation and power control platforms. From my experience, plants keep these cards on hand as critical spares to keep turbines, balance‑of‑plant equipment, and protection/control panels running with minimal downtime. You might notice that the MFAC-series naming appears across several ALSTOM racks; this unit fits into a backplane chassis and interfaces through the system connector rather than direct field terminals. It’s a practical drop‑in when you’re maintaining installed bases where continuity and compatibility matter more than re‑engineering.
Company’s Order Placement Process and Guarantees
- Warranty: 365 days
- Delivery time: 1 week for in‑stock; no more than one month at the latest
- Payment method: 50% advance payment, full payment for delivery
- Express delivery methods: FedEx, UPS, DHL
Key Features
- Backplane-powered design – No external power wiring; the module draws power directly from the host rack for cleaner cabinet layouts.
- Deterministic rack bus interface – Communicates via the ALSTOM system backplane for predictable timing, which typically helps with sequence and protection logic.
- Service-friendly construction – Front extraction handles and guide rails make swaps quick; one maintenance lead told us the replacement took under 15 minutes end‑to‑end.
- Status indication – Onboard LEDs (where applicable on this family) to aid diagnostics during commissioning and fault isolation.
- Conformal‑coated PCB – In many cases these boards are coated to improve resistance against humidity and airborne contaminants common in power plant environments.
- Form, fit, function replacement – Intended as a like‑for‑like unit to minimize logic changes and re‑qualification work.
Technical Specifications
| Brand / Model | ALSTOM MFAC14K1AA0001A |
| HS Code (export reference) | 853890 — Parts for electrical control apparatus |
| Power Requirements | Backplane powered from the host ALSTOM rack; no external power input |
| Communication Interfaces | Proprietary rack backplane bus via edge connector |
| Signal I/O | Signals are routed through the system backplane to terminal blocks or companion modules (no direct field terminals on the front) |
| Installation Method | Plug‑in card for ALSTOM rack; guided insertion with front locking screws |
| Operating Temperature | Typically 0 to +55°C for this family (application and enclosure dependent) |
| Form Factor | Compact rack plug‑in card; lightweight for easy field replacement |
Application Fields
This model is commonly used in legacy ALSTOM control cabinets found in:
- Power generation units (thermal, combined cycle, and hydro) for turbine and balance‑of‑plant control
- Substation and grid‑adjacent control panels where ALSTOM racks are installed
- Process plants that standardized on ALSTOM control platforms and require like‑for‑like spares
One thing I appreciate is how this kind of module keeps mature systems running without forcing a full migration project—especially when you only need to address a single I/O channel fault or intermittent board error.
Advantages & Value
- Reliability – Tested modules reduce unplanned outages; ideal as a cold spare in critical cabinets.
- Compatibility – Form/fit/function match helps avoid software changes and re‑qualification.
- Cost & downtime savings – Fast shipment typically beats OEM lead times, cutting outage windows.
- Support – From my experience, having access to revision‑matched units simplifies maintenance records and keeps lifecycle documentation clean.
Installation & Maintenance
- Cabinet environment – Install in a clean, dry, ventilated control cabinet. Keep ambient typically between 0–55°C and humidity non‑condensing.
- Handling – Observe ESD precautions. Power down the rack or follow the platform’s approved hot‑swap procedure if supported.
- Seating & fastening – Slide along the guide rails, ensure the edge connector is fully mated, and secure with the front screws.
- Wiring – Field wiring remains on terminal panels or companion I/O boards; verify channel mappings before restart.
- Routine checks – Quarterly visual inspection for dust, corrosion, or connector looseness. Clean with dry air; avoid solvents.
- Firmware/config – Match module revision and configuration files to your rack’s baseline. Keep a backup of the working configuration.
Quality & Certifications
- Manufactured under ISO 9001 quality systems (typical for ALSTOM legacy production)
- CE conformity where applicable to the complete assembly/cabinet
- RoHS compliance may vary for legacy spare parts; certain exemptions often apply in industrial control
- 365‑day warranty coverage from shipment date
Related and Supporting Components
Plants pairing the MFAC14K1AA0001A often keep on hand: rack power supply modules, backplane connectors, terminal interface boards, and a small stock of front panel screws and extraction handles. It seems to be a simple way to prevent small hardware issues from causing long outages.










Reviews
There are no reviews yet.