Bently Nevada 350005-01-03-00-00-00 – 3500/05 Rack Chassis for Industrial Condition Monitoring

Brand / Model Bently Nevada 350005-01-03-00-00-00 (3500/05 rack chassis)
HS Code 9031.90 (Parts of measuring or checking instruments)
Power Requirements Provided by installed 3500/15 power supply module (AC or DC, single or redundant)
Dimensions & Weight Standard 3500 rack form factor for cabinet mounting; multi-slot backplane chassis
Operating Temperature Industrial cabinet ambient; typically 0 to +65 °C when installed per guidelines
Signal Input/Output Types Chassis/backplane only; field I/O handled by rear termination modules paired to front monitors
Communication Interfaces Supports 3500/22M (or equivalent) comms module; the chassis itself has no external comms port
Installation Method Cabinet/rack mounting with front module slots and rear I/O positions; dedicated grounding points
contact qrcode

Need help?
Email: sales@fyplc.cn
Tel/WhatsApp: +86 173 5088 0093

Description

Bently Nevada 350005-01-03-00-00-00 – 3500/05 Rack Chassis for Industrial Condition Monitoring

The 350005-01-03-00-00-00 corresponds to the Bently Nevada 3500/05 rack chassis—essentially the backbone of a 3500 monitoring system. From my experience, it’s the part that brings everything together: power supplies, monitor modules, Keyphasor/speed inputs, and communications all slot into this frame and talk across the backplane. You might notice that plants prefer keeping a spare chassis on hand, because when a rack frame is damaged or a new train is added, a like-for-like chassis makes expansion straightforward and avoids rewiring the entire panel.

Bently Nevada 350005-01-03-00-00-00 (3500/05) rack chassis

Company’s Order Placement Process and Guarantees

  • Warranty period: 365 days
  • Delivery time: 1 week for in-stock; no more than 1 month at the latest
  • Payment method: 50% advance payment; full payment for delivery
  • Express delivery methods: FedEx, UPS, DHL

Key Features

  • Native 3500 platform chassis – Hosts the power supply module, monitor cards, Keyphasor/speed, and the comms module over an integrated backplane.
  • Modular slot architecture – Typically supports a multi-slot layout for flexible channel density and redundancy strategies.
  • Redundant power ready – Accepts single or redundant 3500/15 power supplies for higher availability (AC or DC, model dependent).
  • Service-friendly layout – Front modules and rear I/O plates install cleanly; wiring stays accessible for loop checks and PMs.
  • Robust cabinet integration – Designed for control-panel environments with proper grounding points and EMC-conscious construction.

Technical Specifications

The chassis provides mechanical support and a signal/power backplane; active functions depend on installed modules. If you share your existing rack options and module list, we can validate this 350005-01-03-00-00-00 build before shipment.

Brand / Model Bently Nevada 350005-01-03-00-00-00 (3500/05 rack chassis)
HS Code 9031.90 (Parts of measuring or checking instruments)
Power Requirements Provided by installed 3500/15 power supply module (AC or DC, single or redundant)
Dimensions & Weight Standard 3500 rack form factor for cabinet mounting; multi-slot backplane chassis
Operating Temperature Industrial cabinet ambient; typically 0 to +65 °C when installed per guidelines
Signal Input/Output Types Chassis/backplane only; field I/O handled by rear termination modules paired to front monitors
Communication Interfaces Supports 3500/22M (or equivalent) comms module; the chassis itself has no external comms port
Installation Method Cabinet/rack mounting with front module slots and rear I/O positions; dedicated grounding points

Application Fields

  • Centrifugal compressors, steam/gas turbines, and critical pumps requiring continuous vibration and speed monitoring
  • Balance‑of‑plant machinery integrated into a unified 3500 rack for alarms, trips, and trend data
  • Unit expansions or retrofits where keeping existing probe runs and wiring conventions is a priority
  • Standardization programs aiming to simplify spares and maintenance across multiple trains

Advantages & Value

  • Reliability – Proven 3500 platform chassis with robust backplane connectivity and field‑serviceable mechanicals.
  • Compatibility – Works with a wide range of 3500 monitor and comms modules; in many cases it’s a direct replacement chassis.
  • Uptime focus – Clean front/rear access helps technicians complete loop checks and module swaps faster.
  • Procurement confidence – Predictable option coding and a 365‑day warranty reduce project risk.

Installation & Maintenance

  • Mounting & ventilation – Install in a ventilated cabinet or rack; leave clearance for front modules and rear I/O terminations.
  • Grounding – Bond the rack per site EMC standards; maintain single‑point grounding to avoid loops.
  • Wiring discipline – Keep low‑level transducer wiring away from high‑EMI conductors; route shields to the designated points.
  • Slot planning – Follow Bently slotting guidelines for power, monitors, Keyphasor, and comms; label positions for quicker PMs.
  • Care & checks – Periodically tighten fasteners, inspect rear terminals, and verify module health through your monitoring software.

Quality & Certifications

  • CE and RoHS compliance (typical for Bently Nevada 3500 components)
  • UL/cUL suitability for industrial control panels, model dependent
  • Manufacturer’s warranty: 12 months from shipment

A quick field note we hear often: “The replacement rack dropped into the cabinet and the existing module set slotted right in—no surprises.” If you share your current rack option string, power supply type, and module lineup, we’ll confirm that 350005‑01‑03‑00‑00‑00 matches your build and line up a fast shipment.

Reviews

There are no reviews yet.

Be the first to review “Bently Nevada 350005-01-03-00-00-00 – 3500/05 Rack Chassis for Industrial Condition Monitoring”

Your email address will not be published. Required fields are marked *

zzfyplc_Lily

Related products