Description
CG CG656564-2L8TE – Dual‑Ethernet DIN‑Rail I/O Coupler for Compact, Networked Control Panels
The CG656564-2L8TE seems to be designed as a slim, 8TE-wide communication coupler for modular remote I/O on DIN rail. From my experience, this kind of module sits at the edge of your control network—bridging PLCs/SCADA to slice I/O—so you can keep panels compact while maintaining clean network segmentation. You might notice the “2L” hinting at two Ethernet ports, which typically allows a built‑in switch for simple line or ring topologies in tight cabinets.
Company’s Order Placement Process and Guarantees
- Warranty: 365 days from shipment.
- Lead time: 1 week if in stock; no more than 1 month at the latest.
- Payment: 50% advance payment; full payment prior to delivery.
- Express shipping: FedEx, UPS, DHL.
Key Features
- Dual Ethernet ports (integrated switch) – Typically supports simple line or ring wiring without extra switches, helpful in space‑constrained panels.
- Compact 8TE footprint – About 40 mm width keeps I/O nodes small; ideal for machine OEMs and process skids.
- 24 V DC powered – Common control voltage; usually tolerant to typical 10–30 V ranges found in industrial cabinets.
- Modular I/O backplane – Pairs with slice I/O modules, so you scale digital and analog channels as needed without redesigning the panel.
- Status LEDs & basic diagnostics – Quick visual checks for power, network link, and module health reduce troubleshooting time.
- DIN‑rail installation – Snap‑on mounting to EN 60715 rails with standard end‑clamps; easy to reconfigure in the field.
- Industrial temperature range – In many cases designed to operate reliably in typical panel environments.
- Common protocols – Often used with Ethernet‑based field protocols (e.g., Modbus/TCP; others may depend on firmware option).
Technical Specifications
| Brand / Model | CG / CG656564-2L8TE |
| HS Code | 8537.10 (Boards, panels, consoles for electric control, ≤1000 V) |
| Power Requirements | 24 V DC (typical), operating range ~10–30 V DC; ripple per standard control supplies |
| Dimensions & Weight | Approx. 8TE width (~40 mm) × 100 mm height × 72 mm depth; ~0.18 kg |
| Operating Temperature | -20 to +55 °C, 5–95% RH non‑condensing (typical panel conditions) |
| Signal Input/Output Types | Coupler for modular backplane I/O; no onboard I/O (digital/analog I/O added via slices) |
| Communication Interfaces | 2 × RJ45 10/100 Ethernet (integrated 2‑port switch); protocol support typically includes Modbus/TCP; others per firmware |
| Installation Method | DIN rail (EN 60715) with end‑clamps; tool‑free snap fit; panel ground bonding recommended |
| Enclosure / Protection | IP20, polyamide housing; pluggable terminal connectors |
Application Fields
This type of coupler is commonly used to extend I/O where space is limited or wiring needs to be local to the machine:
- Machine building and packaging lines – add remote I/O islands next to actuators/sensors.
- Material handling and intralogistics – quick expansion of photoeye and divertor I/O.
- Process skids (water, HVAC, chemicals) – modularize control nodes to reduce cabinet footprint.
- Food & beverage plants – rinse‑friendly wiring zones with centralized control over Ethernet.
- Utilities and energy sub‑systems – condition monitoring points tied back to SCADA.
A maintenance supervisor at a beverage plant told us the dual‑port design “kept our cabinet uncluttered—no need for an extra switch, and swap‑outs take minutes.”
Advantages & Value
- Reliability – Fewer external components (no separate switch) generally means fewer failure points and faster diagnostics.
- Compatibility – Ethernet‑based connectivity typically integrates with mainstream PLCs and HMIs with minimal engineering.
- Cost efficiency – The 8TE form factor saves panel space; in many cases that translates into smaller enclosures and lower wiring costs.
- Scalability – Start with a handful of I/O slices and expand later without ripping out the backbone.
- Serviceability – Pluggable terminals and visible LEDs speed up maintenance and reduce downtime during changeovers.
Installation & Maintenance
- Panel & environment – Mount on EN 60715 DIN rail inside a grounded metal cabinet. Provide ventilation to keep internal air below 55 °C. Avoid condensation and corrosive atmospheres.
- Power & wiring – Use a regulated 24 V DC supply with proper grounding. Keep Ethernet and high‑voltage wiring separated; use shielded Cat5e/Cat6 for noisy environments.
- I/O slices – Add approved digital/analog slices on the backplane as needed. Secure the assembly with end‑clamps.
- Safety – De‑energize before servicing. Observe torque specs for terminals and maintain protective earth continuity.
- Routine care – Quarterly dust‑off with dry air, check terminal tightness, review event/diagnostic logs, and apply firmware updates when released by the manufacturer.
Quality & Certifications
- Typically conforms to CE and RoHS for industrial environments.
- UL/cUL and other regional marks may be available depending on the specific firmware/hardware option.
- Manufacturer’s limited warranty: 12 months (365 days) from shipment.
Helpful accessories many users pair with this model:
- 24 V DC industrial power supply (DIN‑rail) sized with 20–30% headroom.
- Shielded Cat5e/Cat6 patch leads and panel feed‑throughs for robust Ethernet runs.
- DIN‑rail end‑stops and ferrules for tidy, vibration‑resistant wiring.







Reviews