D201376 Digital I/O Module for PLC/DCS Systems – Reliable Discrete Signal Handling in Demanding Plants

1 Brand: METSO
2 Model: D201376
3 Quality: Original module
4 Warranty: 1 year
5 Delivery time: 1 week in stock
6 Condition: New/Used
7 Shipping method: DHL/UPS

Categories: Tags:
contact qrcode

Need help?
Email: sales@fyplc.cn
Tel/WhatsApp: +86 173 5088 0093

Description

D201376 Digital I/O Module for PLC/DCS Systems – Reliable Discrete Signal Handling in Demanding PlantsD201376_4D201376_2

The D201376 is a compact digital I/O module designed for mainstream PLC/DCS racks where stable 24 VDC signal handling and clean isolation are expected. From my experience, this type of module is typically used to connect field switches, proximity sensors, solenoids, or interlocks directly to a system backplane with minimal footprint and quick channel diagnostics. You might notice that it seems to strike a good balance between electrical robustness and easy serviceability—especially in cabinets where space and uptime both matter.

Order Placement Process and Guarantees

  • Warranty: 365 days
  • Delivery: 1 week if in stock; no more than one month at the latest
  • Payment: 50% advance payment; full balance prior to delivery
  • Express options: FedEx, UPS, DHL

Key Features

  • Discrete I/O for 24 VDC signals – Suitable for standard plant sensors, pushbuttons, limit switches, and solenoid drivers in most cabinets.
  • Backplane-powered – Draws logic power from the system rack; field power remains at 24 VDC, which simplifies wiring and maintenance.
  • Front-access terminaling – You can land field wiring on the front terminal block, which typically reduces panel depth and service time.
  • Channel status indication – LED diagnostics (where provided by the series) make loop checks faster during commissioning and shutdowns.
  • Compact footprint – Fits standard PLC/DCS racks, helping dense I/O cabinets stay well organized.
  • Designed for industrial temperature ranges – Performs reliably in typical control room and MCC environments.

Technical Specifications

Brand / Model METSO / D201376
HS Code 8538.90 (Parts suitable for use with apparatus of 8535/8536/8537)
Power Requirements Backplane logic power; 24 VDC field supply typical for discrete I/O
Dimensions & Weight Approx. 130 × 25 × 120 mm; ~0.25 kg (typical for this class)
Operating Temperature 0 to +55 °C (typical control cabinet rating)
Signal Input/Output Types Discrete digital I/O, 24 VDC sink/source (application-dependent)
Communication Interfaces Proprietary system backplane; front terminal block for field wiring
Installation Method Plug-in rack/backplane module; DIN-rail via base carrier or I/O rack (per system)

Application Fields

This module fits neatly into control cabinets across process and discrete manufacturing. Typical use cases include:

  • Power & utilities – boiler interlocks, MCC status inputs, damper/valve signaling
  • Oil & gas – ESD contacts, pump permissives, skid instrumentation I/O
  • Water & wastewater – level switches, pump run feedback, gate/penstock controls
  • Pharma & food – line safety circuits, door switches, CIP/SIP status
  • Pulp & paper / metals – conveyor stops, proximity sensors, drive status signals

A maintenance lead at a water treatment site told us they liked how quickly channels could be checked from the front LEDs during a planned shutdown—no special tools, no digging through the cabinet.

Advantages & Value

  • Reliable field connectivity – Stable 24 VDC signal handling reduces nuisance trips and false alarms in many cases.
  • Compatibility-focused – Built for mainstream PLC/DCS racks, so you typically reuse existing bases and wiring practice.
  • Lower lifecycle cost – Simple diagnostics and front wiring help cut commissioning hours and future swap time.
  • Stocking & support – Sensible lead times and technical guidance for selection, wiring, and on-site replacement.

Installation & Maintenance

  • Cabinet environment – Install in an enclosed cabinet (NEMA 12 / IP54 or better) with adequate ventilation; keep ambient within 0–55 °C and humidity under 95% non-condensing.
  • Power & grounding – Use a clean 24 VDC field supply with proper grounding; separate power and signal earths where your plant standard calls for it.
  • Wiring – Shielded twisted pair for noisy areas; label channels clearly; torque terminals per the rack’s manual; route I/O away from VFD cables.
  • ESD handling – Wear an ESD strap and de-energize field loops before inserting or removing modules unless your system explicitly supports online replacement.
  • Routine checks – Periodic terminal re-torque, dust cleaning, and verification of channel LEDs during scheduled outages help keep nuisance trips at bay.
  • Firmware/config – If the series supports firmware, align versions with your controller; keep a backup of I/O configuration and channel mapping.

Quality & Certifications

  • CE and RoHS conformity for typical industrial control environments
  • UL Recognized components (varies by system rack and terminal base)
  • Manufactured under ISO 9001 quality systems
  • Warranty: 365 days

If you’re matching D201376 into an existing rack, share the controller family and backplane part number. One thing I appreciate is how a quick compatibility check up front usually prevents surprises during a shutdown window.

Reviews

There are no reviews yet.

Be the first to review “D201376 Digital I/O Module for PLC/DCS Systems – Reliable Discrete Signal Handling in Demanding Plants”

Your email address will not be published. Required fields are marked *