Description
EATON PL9-C6/2-DC – 2‑Pole DC Miniature Circuit Breaker for dependable 6 A protection
The EATON PL9-C6/2-DC is a compact, DIN‑rail mounted DC miniature circuit breaker designed for small to mid‑range direct‑current loads. From my experience, it’s a sensible pick for battery banks, DC control circuits, and telecom power distribution where you want a clean, predictable trip curve and the reassurance of a well-known brand. You might notice that it follows the familiar xPole footprint, so it typically drops into standard 35 mm rails without fuss.
Company’s Order Placement Process and Guarantees
- Warranty: 365 days
- Delivery time: 1 week for in-stock items; no more than one month at the latest
- Payment method: 50% advance payment, full payment for delivery
- Express delivery: FedEx, UPS, DHL
Key Features
- 2‑pole DC protection – Breaks both conductors in DC circuits, which is typically preferred for battery and telecom systems.
- C‑curve tripping – C‑characteristic suits mixed loads and inrush conditions; in many cases it reduces nuisance trips on inductive loads.
- Rated current 6 A – A practical choice for branch protection on instrumentation, control loops, and small DC feeders.
- DIN‑rail form factor – Standard 35 mm rail mounting keeps panel integration straightforward.
- Clear status indication – You can visually check the switch position; technicians appreciate the quick troubleshooting.
- Panel-friendly width – Two modules (about 36 mm) help save space in dense enclosures.
- EATON ecosystem compatibility – Works with common accessories like busbar combs and lockout tabs, simplifying multi‑circuit builds.
Technical Specifications
| Brand / Model | EATON PL9-C6/2-DC |
| Product Type | DC Miniature Circuit Breaker (MCB), 2‑pole, C‑curve, 6 A |
| HS Code | 8536.20 (Automatic circuit breakers) |
| Power Requirements | None (self‑powered from the protected circuit) |
| Poles / Rated Current | 2 poles / 6 A |
| Trip Curve | C (suitable for moderate inrush loads) |
| Operating Temperature | Typically −25 °C to +55 °C (derating may apply at higher ambient) |
| Dimensions & Weight | Approx. 2 modules wide (~36 mm); DIN‑rail height footprint |
| Signal I/O | Line/Load screw terminals; mechanical switch position indicator |
| Communication Interfaces | None |
| Installation Method | 35 mm DIN rail (EN 60715); front wiring |
Application Fields
In many cases, the PL9-C6/2-DC is selected for low‑voltage DC distribution where predictable protective behavior matters more than size: battery management panels, DC control cabinets on machinery, telecom power shelves (−48 VDC), small UPS distribution, AGV/AMR charging bays, and laboratory DC rails. One customer running a compact telecom repeater cabinet told us the 2‑pole format made maintenance safer by fully isolating both conductors during service.
Advantages & Value
- Reliable protection – C‑curve performance seems to be the “sweet spot” for mixed DC loads.
- Panel efficiency – Narrow footprint helps keep enclosures small, which can cut cabinet costs.
- Compatibility – Fits standard rails and works with common busbar combs and locking accessories.
- Serviceability – Clear actuation and tool‑friendly terminals make swaps quick during downtime.
- Procurement predictability – Eaton part numbering is consistent, so cross‑site standardization is easier.
Installation & Maintenance
- Cabinet environment – Mount on 35 mm DIN rail inside a ventilated enclosure. Keep ambient within the specified range; consider derating at elevated temperatures.
- Wiring – Use appropriately rated DC cables. Tighten terminals to the torque printed on the device label. For DC systems, observe polarity and follow Eaton’s wiring diagrams for 2‑pole use.
- Coordination – Coordinate with upstream fuses/breakers to ensure selectivity. In most cases, proper upstream sizing reduces nuisance trips.
- Safety – Isolate and verify absence of voltage before work. Lockout/tagout where required.
- Routine checks – Periodically re‑torque terminals, clear dust, and verify mechanical operation. If firmware is used in the upstream supply or monitoring, keep that updated to maintain proper trip coordination.
Quality & Certifications
- CE marking; RoHS compliance
- Designed and tested to relevant IEC/EN standards for MCBs (commonly IEC/EN 60947‑2 and/or 60898‑2 for DC variants)
- Manufacturer’s warranty: 12 months
Related Accessories (optional)
- DIN‑rail busbar combs for multi‑circuit builds
- Padlockable toggle lock/lockout devices for maintenance safety
- Auxiliary status contacts (where supported) for panel indication
- End‑stops and rail markers for tidy panel layout
If you’re standardizing multiple DC panels, this model typically strikes a nice balance of footprint and protection. One thing I appreciate is how consistently it fits alongside other xPole breakers without reworking the rail or labels.










Reviews